Item | Specification | ||
Basic functions | Over load capability | G type: 150% rated current 60s | |
P type: 120% rated current 60s | |||
Torque boost | Auto torque boost function; Manual torque boost 0.1%--30.0% | ||
V/F curve | Linear V/F, Multi-point V/F and square V/F curve(power of 1.2,1.4,1.6,1.8,2) | ||
V/F separation | 2 ways: separation and semi-separation | ||
Acc./dec. curve | Straight line or S curve acceleration and deceleration mode, | ||
Four kinds of acceleration and deceleration time. | |||
Acceleration and deceleration time range from 0.0s to 6500s. | |||
DC braking | DC braking frequency: 0.00Hz to maximum frequency; | ||
Braking time: 0.0s to 36s | |||
Brake current :0%---100% | |||
Jog control | Jog frequency range: 0.00Hz---50.00Hz | ||
Jog acceleration/deceleration: 0.0s--6500.s | |||
Simple PLC | It can realize at maximum of 16 segments speed | ||
functions | Multiple segment speed running | Running via the built-in PLC or control termina | |
Built-in PID | It is easy to realize process-controller closed loop control system | ||
Auto voltage regulation | It can keep constant output voltage automatically in the case of change of network voltage | ||
Over-voltage/current stall control | It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process | ||
Quick current limit | Minimize the over-current fault, protect normal operation of the AC drive | ||
Torque limit&control | “Excavators”characteristics, automatically limit torque during operation, prevent frequent over-current tripping. Closed loop vector mode can realize the torque control. | ||
Personalized function | Instantaneous Stop non-stop | When instantaneous power off, voltage reduction is compensated through load feedback energy, which could make AC drive keep running in a short period of time. | |
Rapid current limit | To avoid AC drive frequent over-current fault | ||
Timing control | Timing control function: set time range:0--6500min | ||
RUNNING | Running command source | Operation panel; control terminals; Serial communication pot. You can perform switch over between these sources in various ways. | |
Frequency source | There are a total of 10 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. You can perform switch over between these sources in various ways. | ||
Input terminal | Standard: 5 digital input(X) terminals 2 analog input(AI) terminals, one support 0-10v voltage input or 0- 20mA current input terminal | ||
Output terminal | Standard: 2 digital output (DO) terminal; 2 relay output terminal; 2 analog output (AO) terminal that supports 0 ~ 20mA current output or 0 ~ 10V voltage output. | ||
Display and operation on the operation panel | Keyboard potentiometer | Equipped with keyboard potentiometer or coding potentiometer | |
Protection mode | Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection , overheat protection and overload protection | ||
Optional parts | LCD operation panel, braking unit | ||
Environment | Installation location | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt. | |
Altitude | Lower than 1000m | ||
Ambient temperature | -10℃ to +40℃ (de-rated if the ambient temperature is between 40℃ and 50℃) | ||
Humidity | Less than 95% RH, without condensing | ||
Vibration | Less than 5.9m/s2 (0.6g) | ||
Storage temperature | -20℃ to +60℃ | ||
IP level | IP20 | ||
Pollution degree | PD2 | ||
Power distribution system | TN, TT |