Electrical Specifications | ||||
V AC (40-500Hz) | Range | 600.0 mV 6.000 V 60.00 V 600.0 V | ||
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V | |||
Accuracy | 3.0%±3 digit 1.0%±3 digit | |||
V DC | Range | 6.000 V 60.00 V 600.0 V | ||
Resolution | 0.001 V 0.01 V 0.1 V | |||
Accuracy | 0.5%±3 digit | |||
Resistance Ohms | Range | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | ||
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | |||
Accuracy | 0.5 %±3 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 1.5%±3 digit | |||
Capacitance | Range | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000.0 μF | ||
Resolution | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | |||
Frequency (10 Hz – 100 kHz) | Range | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | ||
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | |||
Duty Cycle | Range | 0.1 % to 99.9 % | ||
Resolution | 0.1 % | |||
General Specifications | ||||
CAT Rating | CAT III 600 V | |||
V AC Range | 600.0 V | |||
V DC Range | 600.0 V | |||
Ohms Range | 40.00 MΩ | |||
Auto Shutoff | Y | |||
Continuity | Y | |||
Capacitor | 100.0 μF | |||
Frequency | 100.0 kHz | |||
Hold | No | |||
Duty Cycle | Yes | |||
Size | 130 mm x 65 mm x 27mm | |||
Weight | 160 g | |||
Battery | Two AAA | |||
Warranty | 1 year | |||
Environmental Specifications | ||||
Operating Temperature | 0 °C to +40 °C | |||
Storage Temperature | -30 °C to +60 °C | |||
Operating Humidity | Non condensing (<10 °C) <=90% RH (at 10 °C to 30 °C) <=75% RH (at 30 °C to 40 °C) (Without Condensation) | |||
Operating Humidity, 40 MΩ | 80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C | |||
Operating Altitude | 2,000 meters | |||
Storage Altitude | 12,000 meters | |||
IP Rating | IP 40 per IEC 60529 | |||
Vibration Requirements | MIL-PRF-28800F, Class 2 | |||
Drop Test Requirements | -10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment Shipping container drop per Fluke SOP 39. | |||
EMI, RFI, EMC | Must meet all applicable requirements in IEC/EN 61326-1 | |||
Absorption/Corrosion | Per Fluke SOP 39.1 | |||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC |