Model Encoding:
AC Output Receptacles (optional):
MODEL | TS-400-112 | TS-400-124 | TS-400-148 | |
OUTPUT | RATED POWER | 400W | ||
MAXIMUM OUTPUT POWER | 460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.) | |||
AC VOLTAGE | Factory setting set at 110VAC | |||
100 / 110 / 115 / 120VAC selectable by setting button S.W | ||||
FREQUENCY | 60±0.1Hz 50/60Hz selectable by setting button | |||
WAVE FORM | True sine wave (THD<3%) | |||
AC REGULATION | ±3.0% at rated input voltage | |||
FRONT PANEL INDICATOR | Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal | |||
INPUT | BAT. VOLTAGE | 12V | 24V | 48V |
VOLTAGE RANGE | 10.5 ~ 15VDC | 21 ~ 30VDC | 42 ~ 60VDC | |
DC CURRENT | 40A | 20A | 10A | |
NO LOAD CURRENT DRAW | 1.25A | 0.63A | 0.32A | |
OFF MODE CURRENT DRAW | ≤1mA | |||
EFFICIENCY | 84.5% | 86% | 87% | |
BATTERY TYPES | Open & sealed Lead Acid | |||
BATTERY INPUT PROTECTION | FUSE | 40A*2 | 40A*1 | 20A*1 |
BAT. LOW ALARM | 11.3±4% | 22.5±4% | 45±4% | |
BAT. LOW SHUTDOWN | 10.5±4% | 21±4% | 42±4% | |
BAT. POLARITY | By internal fuse open | |||
OUTPUT | OVER TEMPERATURE | 85°C± 5°C | 75°C±5°C | 70°C±5°C |
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor | ||||
OUTPUT SHORT | Protection type : Shut down o/p voltage, re-power on to recover | |||
OVER LOAD | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. | |||
Protection type : Shut down o/p voltage, re-power on to recover | ||||
GFCI PROCTECTION | Optional (Only type F) | |||
FUCTION | REMOTE CONTROL | Open : Normal work ; Short : Remote off | ||
ENVIRONMENT | WORKING TEMP. | -10 ~ +40°C@ 100% load ; +60°C@ 50% load | ||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -30 ~ +70°C/ -22 ~ +158oF, 10 ~ 95% RH | |||
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |||
SAFETY & EMC | SAFETY STANDARDS | Design refer to UI458 | None | |
LVD | None | |||
WITHSTAND VOLTAGE | Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC | |||
ISOLATION RESISTANCE | Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | |||
EMC EMISSION | Compliance to FCC class A | |||
EMC IMMUNITY | None | |||
OTHERS | MTBF | 104.7K hrs min. MIL-HDBK-217F (25°C) | ||
DIMENSION | 205*158*67mm (L*W*H) | |||
PACKING | 1.73Kg; 6pcs/11.4Kg/1.55CUFT |
MODEL | TS-400-212 | TS-400-224 | TS-400-248 | |
OUTPUT | RATED POWER | 400W | ||
MAXIMUM OUTPUT POWER | 460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.) | |||
AC VOLTAGE | Factory setting set at 230VAC | |||
200 / 220 / 230 / 240VAC selectable by setting button S.W | ||||
FREQUENCY | 50±0.1Hz 50/60Hz selectable by setting button | |||
WAVE FORM | True sine wave (THD<3%) | |||
AC REGULATION | ±3.0% at rated input voltage | |||
FRONT PANEL INDICATOR | Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal | |||
INPUT | BAT. VOLTAGE | 12V | 24V | 48V |
VOLTAGE RANGE | 10.5 ~ 15VDC | 21 ~ 30VDC | 42 ~ 60VDC | |
DC CURRENT | 40A | 20A | 10A | |
NO LOAD CURRENT DRAW | 1.25A | 0.63A | 0.32A | |
OFF MODE CURRENT DRAW | ≤1mA | |||
EFFICIENCY | 86% | 87.5% | 88.5% | |
BATTERY TYPES | Open & sealed Lead Acid | |||
BATTERY INPUT PROTECTION | FUSE | 40A*2 | 40A*1 | 20A*1 |
BAT. LOW ALARM | 11.3±4% | 22.5±4% | 45±4% | |
BAT. LOW SHUTDOWN | 10.5±4% | 21±4% | 42±4% | |
BAT. POLARITY | By internal fuse open | |||
OUTPUT | OVER TEMPERATURE | 85°C± 5°C | 75°C±5°C | 70°C±5°C |
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor | ||||
OUTPUT SHORT | Protection type : Shut down o/p voltage, re-power on to recover | |||
OVER LOAD | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. | |||
Protection type : Shut down o/p voltage, re-power on to recover | ||||
GFCI PROCTECTION | None | |||
FUCTION | REMOTE CONTROL | Open : Normal work ; Short : Remote off | ||
ENVIRONMENT | WORKING TEMP. | -10 ~ +40°C@ 100% load ; +60°C@ 50% load | ||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -30 ~ +70°C/ -22 ~ +158oF, 10 ~ 95% RH | |||
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |||
SAFETY & EMC | SAFETY STANDARDS | None | ||
LVD | EN60950-1 | |||
WITHSTAND VOLTAGE | Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC | |||
ISOLATION RESISTANCE | Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | |||
EMC EMISSION | Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark | |||
EMC IMMUNITY | Compliance to EN61000-4-2,3,8 | |||
OTHERS | MTBF | 104.7K hrs min. MIL-HDBK-217F (25°C) | ||
DIMENSION | 205*158*67mm (L*W*H) | |||
PACKING | 1.73Kg; 6pcs/11.4Kg/1.55CUFT |
Packing:
Shipping:
Strict, professional production and test, large stock for fast shipping.
What Certification do we have?
What our Power Supply can do for you?
SUCCESS IS A RESULT OF OUR COMMITMENT TO A QUALITY SERVICE IN PARTNERSHIP WITH OUR CLIENTS
1. What we sell is 100% Genuine Mean Well Power Supply;
2. Small quantity orders acceptable;
3. We will choose the most suitable shipping way for you and inform you the cost advance, decision will be made by you;
4. We have larger stocks and this support us can make a very prompt shipping;
5. To assure you the maximum comfort and satisfaction, we accept pay via T/T, Paypal, Western Union;
6. Price could be negotiated for more and large quantity;
7. Your enquiry will be quickly responsed, we will choose the most suitable products and quote the most competitive price for you.
If you are interested in other models, please hit below links for details....