ELECTRICAL PERFORMANCE | ||
Nominal Voltage | 12.8 V | |
Nominal Capacity | 100 Ah | |
Capacity @ 20A | 300 min | |
Energy | 1280 Wh | |
Resistance | ≤30 mΩ @ 50% SOC | |
Self Discharge | <3% / Month |
CHARGE PERFORMANCE | ||
Recommended Charge Current | 20A | |
Maximum Charge Current | 100A | |
Recommended Charge Voltage | 14.6V | |
BMS Charge Cut-Off Voltage | <15.6 V (3.9V/Cell) | |
Reconnect Voltage | >14.4 V (3.6V/Cell) | |
Balancing Voltage | <14.4 V (3.6V/Cell) | |
Maximum Batteries in Series | 4 (*Consult MUST) |
DISCHARGE PERFORMANCE | ||
Maximum Continuous Discharge Current | 100 A | |
Peak Discharge Current | 200 A (3s) | |
BMS Discharge Cut-Off Current | 300 A ±10 A (30ms) | |
Recommended Low Voltage Disconnect | 11 V (2.75V/Cell) | |
BMS Discharge Cut-Off Voltage | >8.0 V (2s) (2.0V/Cell) | |
Reconnect Voltage | >10.0 V (2.5V/Cell) | |
Short Circuit Protection | 250 ~ 500 μs |
COMPLIANCE | ||
Certifications | CE (battery) UN38.3 (battery) UL1642 & IEC62133 (cells) | |
Shipping Classification | UN 3480, CLASS 9 |