PH3000 Pro series is very economical pure sine wave inverter , and AC charger from 35A to 70A .Solar /AC priority configurable . When solar priority , in case its charge current lower than inverter’s charger from AC , AC will supplement to charge the batteries ,to optimize charging. With low frequency transformer ,it enable the inverter to operate with all kinds of home appliances.
PH3000 Pro series low frequency power inverter Features:
MODEL | PH30-1KW PRO | PH30-1.5KW PRO | PH30-2KW PRO | PH30-3KW PRO | PH30-4KW PRO | PH30-5KW PRO | PH30-6KW PRO | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Default Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 48VDC | 24VDC | 48VDC | 24VDC | 48VDC | 24VDC | 48VDC |
INVERTER OUTPUT | |||||||||||||||
Reted Power | 1.0KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | ||||||||
Surge Rating (20ms) | 3.0KVA | 4.5KVA | 6.0KVA | 9.0KVA | 12KVA | 15KVA | 18KVA | ||||||||
Capable Of Starting Electric Motor | 1HP | 1HP | 1HP | 2HP | 3HP | ||||||||||
Waveform | Pure sine wave/ same as input (bypass mode) | ||||||||||||||
Nominal Output Voltage RMS | 100V/110V/120VAC 220V/230V/240VAC(±10% RMS) | 220V/230V/240VAC(±10% RMS) | |||||||||||||
Output Frequency | 5OHz/60Hz±0.3 Hz | ||||||||||||||
Inverter Efficiency(Peak) | >88% | ||||||||||||||
Line Mode Efficiency | >95% | ||||||||||||||
Power Factor | 1.0 | ||||||||||||||
Typical Transfer Time | 10ms(max) 10ms(max) | ||||||||||||||
AC INPUT | |||||||||||||||
Voltage | 230VAC | ||||||||||||||
Selectable Voltage Range | 96~132VAC 155~280VAC(For Personal Computers) | ||||||||||||||
Frequency Range | 50Hz/60Hz (Auto sensing) 40~80Hz | ||||||||||||||
BATTERY | |||||||||||||||
Minimum Start Voltage | 10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
Low Battery Alarm | 10.5VDC±0.3V for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
Low Battery Cutoff | 10.0VDC±0.3V for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
High Voltage Alarm | 16.0VDC±0.3V for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
High Battery Voltage Recover | 15.5VDC±0.3V for12VDC mode (*2 for 24VDC, ) | ||||||||||||||
Idle Consumption-Search Mode | <25W when power saver on | ||||||||||||||
CHARGER | |||||||||||||||
Output Voltage | Depends on battery tvpe | ||||||||||||||
Charger AC Input Breaker Rrating | 10A | 30A | 30A | 30A | 40A | ||||||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode) | ||||||||||||||
Maximum Charge Current | 35A | 20A | 45A | 25A | 65A | 35A | 75A | 45A | 30A | 65A | 35A | 70A | 40A | 75A | 50A |
BYPASS & PROTECTION | |||||||||||||||
Input Voltage Waveform | Sine wave (grid or generator) | ||||||||||||||
Nominal Input Frequency | 50Hz or 60Hz | ||||||||||||||
Overload Protection (SMPS Load) | Circuit breaker | ||||||||||||||
Output Short Circuit Protection | Circuit breaker | ||||||||||||||
Bypass Breaker Rating | 10A | 30A | 30A | 30A | 40A | ||||||||||
Max Bypass Current | 30Amp | ||||||||||||||
SOLAR CHARGER | |||||||||||||||
Maximum PV Charge Current | 50A | ||||||||||||||
DC Voltage | 12V/24V/48 | ||||||||||||||
PWM Range @ Operating Voltage | 15~80VDC | ||||||||||||||
Maximum PV Array Open Circuit Voltage | 90VDC | ||||||||||||||
Maximum Efficiency | >97% | ||||||||||||||
Standby Power Consumption | <2W | ||||||||||||||
MECHANICAL SPECIFICATIONS | |||||||||||||||
Mounting | Wall mount | ||||||||||||||
Dimensions (W*H*D) | 426*206*178 mm | 601*206*178 | |||||||||||||
Net Weight (Solar CHG) kg | 16.5 | 17 | 21.1 | 20 | 26 | 24.5 | 24.8 | 38.2 | 35.8 | 45.2 | 45 | 45.2 | 45 | ||
Shipping Dimensions(W*H*D) | 570*335*300mm | 750*335*300mm | |||||||||||||
Shipping Weight (Solar CHG) kg | 19.3 | 20 | 24.1 | 22.8 | 29.1 | 27.5 | 27.5 | 42.3 | 40 | 49.5 | 49.3 | 49.5 | 49.3 | ||
OTHER | |||||||||||||||
Operation Temperature Range | 0°C to 40°C | ||||||||||||||
Storage Temperature | -15°C to 60°C | ||||||||||||||
Audible Noise | 60dB MAX | ||||||||||||||
Display | LED+LCD | ||||||||||||||
Standard Warranty | 1 year |
Power Rate(w) | backup time(H) @1*100Ah | backup time(H) @2*100Ah | backup time(H) @4*100Ah | backup time(H) @4*200Ah | backup time(H) @8*200Ah | ||
---|---|---|---|---|---|---|---|
1000 | 0.4806 | 1.602 | 3.50304 | 7.6896 | |||
2000 | 0.2136 | 0.4806 | 1.602 | 3.50304 | 7.6896 | ||
3000 | 0.1068 | 0.2848 | 0.8544 | 2.136 | 4.8416 | ||
4000 | 0.2136 | 0.4806 | 1.602 | 3.50304 | |||
5000 | 0.12816 | 0.34176 | 1.19616 | 2.73408 | |||
6000 | 0.1068 | 0.2848 | 0.8544 | 2.136 |
MUST Factory Production Line :
About MUST :
Must Company Information |
Headquarter & Factory Location | In HongKong & Shenzhen,Guangdong China Mainland |
Industry Experience | 20 Years Experienced Manufacturer |
Product Range | Inverter,Solar Inverter, Off-grid Inverter Grid-tie Solar Inverter, MPPT Solar Charge Controller, Solar Panel, Solar Battery, Solar System |
Main Market | Africa, Middle East & Asia ( Ukraine, Russia, Vietnam, Pakistan, Nigeria, Kenya, South Africa, Ghana,etc.) |
Factory | 8000 Square Meters, 500 workers |
Department | 8-teams Marketing Dept, 4-team R&D, 1 Manufacturing Center, QA Office, After-sale Service Dept. |
Certificate |
ISO9001:2015, CE, IEC,SAA, SGS, Soncap,etc |
Patent | Software Patent, Design Patent, Project Patent |
Customers Service:
(1)Warranty :
Our product warranty is valid for 12 months after delivery. We undertake to repair any malfunctioned units due to defective components of inadequate workmanship ,but specially expecting any defects resulting from normal wear and tear of improper use of the products.
(2)Lead time:
a.sample orders (1-2pcs)will be delivered from our factory within 7working days .
b.Bulk orders will be delivered from our factory within 25 working days.
(3)shippment :
By sea ,airway , EMS, DHL, FedEx, TNT, UPS or other express.
(4)Payment: T/T , Western Union,L/C
Contact US:
Want to know more about our Company, Products, Price, Packing, Shipping and
any discount? Let's Inquiry NOW !!!!!