EH5000 Series High Frequency LCD Online UPS
Main features:
1.True on-line double conversion technology with advanced microprocessor control
2.Wide input voltage range
3.LCD display
4.Zero transfer time
5.Protection against all type of power problems
6.Self test while start of the UPS
7.Site wiring fault warning
8.On-battery power-on function
9.Smart RS232 communication interface
10.Intelligent slot available
Sealed lead-acid, maintenance free battery
Technology specification:
Model | HC1K(S) | HC1.5K(S) | HC2K(S) | HC3K(S) | |
CAPACITY | 1000 VA/700 W | 1500VA/1050 W | 2000VA/1400 W | 3000VA/2100 W | |
INPUT | |||||
Voltage Range | Low Line Transfer | 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 % or | |||
80 VAC / 70 VAC / 60 VAC / 50 VAC ± 5 % | |||||
(based on load percentage 100%-80%/80%-70%/70%-60%/60%-0) | |||||
LowLine Comeback | 175 VAC ± 5 % or 85 VAC ± 5 % | ||||
High Line Transfer | 300 VAC ± 5 % or 150 VAC ± 5 % | ||||
High Line | 290 VAC ± 5 VAC or 143 VAC ± 3 VAC | ||||
Comeback | |||||
Frequency Range | 40 Hz ~ 70 Hz | ||||
Phase | Single phase with ground | ||||
Power Factor | ≥0.99 @ 220-230 VAC (input voltage) | ||||
OUTPUT | |||||
AC Voltage Regulation (Bat. Mode) | ±3% | ||||
Frequency Range | 47 ~ 53 Hz or 57 Hz ~ 63 Hz | ||||
(Synchronized Range) | |||||
Frequency Range (Bat. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz | ||||
Current Crest Ratio | 03:01 | ||||
Harmonic Distortion | <= 3 % THD (Linear Load) | <= 4 % THD (Linear Load) | |||
<= 6 % THD(Non-linear Load) | <= 7 % THD(Non-linear Load) | ||||
Transfer Time | AC to DC | Zero | |||
Inverter to Bypass | 4 ms (Typical) | ||||
Waveform(Bat. Mode) | Pure Sine Wave | ||||
EFFICIENCY | |||||
To AC Mode | 85% | 88% | |||
To Battery Mode | 83% | ||||
BATTERY | |||||
Standard Model | Battery Type | 12 V / 7 AH | 12 V / 9 AH | 12 V / 7 AH | 12 V / 7 AH |
Numbers | 3 | 3 | 8 | 8 | |
Typical Recharge Time | 4 hours recover to 90% capacity | ||||
Charging Current (max.) | 1.0 A | ||||
Charging Voltage | 41.0 VDC ± 1% | 102.1 VDC ± 1% | |||
Long-run Model | Battery Type/Numbers | Depending on the capacity of external batteries | |||
Charging Current (max.) | 8.0 A | ||||
Charging Voltage | 41.0 VDC ± 1% | 102.1 VDC ± 1% | |||
INDICATORS | |||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||
ALARM | |||||
Battery Mode | Sounding every 4 seconds | ||||
Low Battery | Sounding every second | ||||
Overload | Sounding twice every second | ||||
Fault | Continuously sounding | ||||
PHYSICAL | |||||
Size DXWXH (mm) | 390 X145 X 210 | 455 X 190 X 330 | |||
OPERATING ENVIRONMENT | |||||
Humidity | 20-90 % RH @ 0- 40°C (non-condensing) | ||||
Noise Level | Less than 45dB @ 1 Meter | ||||
MANAGEMENT | |||||
Smart RS-232/USB | Supports Windows®98/2000/2003/XP/Vista/2008,Windows®7,Linux,and MAC | ||||
Optional SNMP | Power management from SNMP manager and web browser |
Model | EH5000-H6K | EH5000-H6KS | EH5000-H10K | EH5000-H10KS | |
CAPACITY | 6000 VA / 4200 W | 10000 VA / 7000 W | |||
INPUT | |||||
Voltage Range | Low Line Transfer | 176 VAC @ 100% load / 110 VAC @ 50% load | |||
Low Line Comeback | 186 VAC @ 100% load / 120 VAC @ 50% load | ||||
High Line Transfer | 300 VAC | ||||
High Line | 290 VAC | ||||
Comeback | |||||
Frequency Range | 46~54 Hz or 56~64 Hz | ||||
Phase | Single phase with ground | ||||
Power Factor | ≥0.99 @ 100% load | ||||
OUTPUT | |||||
AC Voltage Regulation (Bat. Mode) | ±1 % | ||||
Frequency Range | 46~54 Hz or 56~64 Hz | ||||
(Synchronized Range) | |||||
Frequency Range (Bat. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
Current Crest Ratio | 3:1 | ||||
Harmonic Distortion | <= 3 % THD (Linear Load)/<= 6 % THD(Non-linear Load) | ||||
Transfer Time | AC to DC | Zero | |||
Inverter to Bypass | Zero | ||||
Waveform(Bat. Mode) | Pure Sine Wave | ||||
EFFICIENCY | |||||
To AC Mode | 89% | ||||
To Battery Mode | 88% | ||||
BATTERY | |||||
Battery Type | 12 V / 7 AH | Depending on applications | 12 V / 9 AH | Depending on applications | |
Numbers | 16 | 16 | 16 | 16 | |
Typical Recharge Time | 7 hours recover to 90% capacity | Depending on battery capacity | 9 hours recover to 90% capacity | Depending on battery capacity | |
Charging Current (max.) | 1.0 A | 4.0 A | 1.0 A | 4.0 A | |
Charging Voltage | 273 VDC | 273 VDC | 273 VDC | 273 VDC | |
INDICATORS | |||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||
LED Display | Sixteen LEDs indicating UPS status, Load level, Battery level, overload, fault, and programmable outlet | ||||
ALARM | |||||
Battery Mode | Sounding every 4 seconds | ||||
Low Battery | Sounding every second | ||||
Overload | Sounding twice every second | ||||
Fault | Continuously sounding | ||||
OPERATING ENVIRONMENT | |||||
Humidity | 20-90 % RH @ 0- 40°C (non-condensing) | ||||
Noise Level | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter | |||
CMANAGEMENT | |||||
Smart RS-232/USB | Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC | ||||
Optional SNMP | Power management from SNMP manager and web browser |
Online Ups 3kva front and back panel:
Online Ups 3kva picture inside:
Testing Equipment:
Shenzhen Must Power Limited established in 1998, which is a professional hi-tech enterprise specialized in Power Inverter,Solar Power, and Battery development, manufacturing, sales and after-service.
Our comprehensive product lines include: Power inverter, Solar inverter, Solar charge controller, Solar battery, Solar power Pack and some other related Solar products.Most of products from Mustups applied with ISO, CE, FCC certificates. The main markets are Ukraine, Russia, Vietnam, Thailand, Pakistan, India, etc.
Oversea Fair:
MUST team:
Payment & Shipping
1. Payment: T/T (Telegraphic transfer), and Western Union
2. Shipping: DHL, FEDEX, UPS, EMS, Airway and By Sea
Samples and OEM
1-Year Warranty on MUST POWER Products
Q1: How to choose a right inverter?
A1:Tell us your demand, then our sales will recommend a suitable inverter to you.
Q2: What's the different between inverter and solar inverter?
A2: Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of inverter?
A4: One year warranty on Must-Solar product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.
Contact Nancy