This instrument is designed and manufactured as per standards GB/T 261 Determination of Flash Point - Pensky-Martens closed cup method,American Material and ASTM D93 Standard Test Method for Flash
Point by Pensky-Martens Closed Cup Tester.
It is used to make determination of the closed cup flash point of the petroleum products.According to the standard method,It could determine the flash point of flammable liquid, liquid with suspended particles,liquid tending to film under the test condition and other type liquids.
The instrument is widely used in petroleum industry,railway,electricity,universities and research institutes etc. departments.
Measurement range: | 40~300℃ |
Standards: | GB/T 261 and ASTM D93 |
Temperature measurement: | High precision PT100 |
Flash point measurement: | Miniature thermocouple |
Heating rate: |
(5~6)℃/min GB/T 261 A,ASTM D93 A (1~1.5)℃/min GB/T 261 B,ASTM D93 B |
Heater: | AC220V,0.5kW |
Stirring rate: | (90-120)rpm(GB/T 261 A;ASTM D93 A) 250rpm(GB/T 261 B;ASTM D93 B) (90-120)rpm(ASTM D93 C) |
Gas source: | Liquefied petroleum gas,Dimethylmethane |
Power supply: | AC220V 5A 50Hz |
Dimension: | 384mm×418mm×328mm(L×W×H) |
Net weight: | Around 15kg |
I. Main technical features
1. Standards:GB/T 261,ASTM D93
According to ASTM D93,It could do A,B and C test.
2. Adopt the German brand High precision sensor,German quality IPC(Industrial Personal Computer), 8 inch colorful touch LCD display,automatical heating,testing and igniting etc.functions.
3. With the barometric pressure sensor, It can correct the influence of atmospheric pressure and calculate the correction automatically.
4. Stir the sample with the stepping motor,stable rotate speed,high accuracy,completely meet the stirring rate of GB/T 261 and ASTM D93 standards.
5. Store 200 test results,print the results by the miniprinter,transform the data to LIMS system according to the self-development software---Sinopec Lab Information Management System.
6. Gas supply design:1 solenoid valve to control the total gas source and 2 channels gas source adjusting needle valves.The total gas source valve could be opened or closed automatically,to ensure the gas safety.
The gas source of the kindling and igniting head could be adjusted respectively to realize the best of both worlds.
7. With the manual operation mode,It checks and simulates the work condition of the instrument various functions, to find the problem timely and solve the issue.
astm d93 pensky martens flash point tester Selection List
Name | Closed Cup Flash Point | Automatic Fast Low Temperature Closed Cup Flash Point |
||||
Item | GD-261 (2008 standard) |
GD-261-1 | GD-261AT | GD-261DT | GD-5208 | GD-5208D |
Picture | ||||||
Application |
Suitable to detect above 40°,volatile chemical materials and finished fuel oil |
Suitable to detect painting,oil paint,alcohol,cosmetics and volatile expensive sample |
||||
Temperature control range |
40~300℃,Rod type mercurial thermometer,20 08 standard. |
40-300℃,Pt100 Sensor | Flash Point detecting range (-30~ 50)℃ |
Flash Point detecting range (0~100) ℃ |
||
Automaticity | Manual operation,pressing the spring knob to ignite |
Automatical igniting—one revolution to ignite at a time automatically,single chip temperature control,temperature display,LCD |
Automatical printing |
Manual uncapping,inniting,automatical detecting,printing data automatically |
||
Standard | ASTM D93 |
We have developed sales channels in many countries such as UAE, Saudi Arabia,Malaysia, Thailand, Pakistan, India, Germany, Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other countries worldwide. And we have gained strong advantage and high reputation in international market.
After several years’ development, our products have become high intelligent and wide coverage.
And our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument.
Brazil ANALITICA LATIN AMERICA 2017 2017 Photos Show
Please feel FREE to contact us if you have any needs. And welcome to visit our OFFICIAL WEBSITE at:
http://www.lab-testkit.com/