Handheld Long Distance Cable Fault Detecting Device
certification:
CE ISO
MOQ:
1
After service:
yes
power:
electronic/electric cable finder
usage:
testing machine/electric cable finder
Test distance:
up to 165Km
Test pulse:
0.2~9.9μs,arbitrary adjustable
Deviation:
no more than ±0.25%
Sampling frequency:
30M,60M,120M
Supply Ability
Supply Ability:
800 Unit/Units per Month Under Ground Cable Fault Locator
Packaging & Delivery
Low Deviation Electric Power Portable Under Ground Cable Fault Locator
Product Description
detector underground cables advantage:
one trolley structure, on-site handling convenience.
field test without complex wiring, switch, all the way to test and voltage grade are controlled by weak current internal high pressure switch for automatic switching.
for a variety of 220 v - 220 kv voltage class power cables of low resistance, high resistance leakage fault, flashover failure for rapid positioning and fixed point.
the integration of multiple dc high voltage generator unit, several high voltage capacitor, arc stability and various signal collection in a body, is advantageous for the operation of fault location system.
5 reverse test mode switch, three voltage grade by low pressure low voltage control switch.
the international leading test method, test troubleshooting is very simple.
low technical level requirements for equipment operators.
DC DC voltage up to 40 kv.
8/16/32 KV, every shift voltage up to 2048 j impact energy output, ranging arc longer, fixed point of failure when a loud noise.
high impedance fault detection directly without burning through.
wide wheel to ensure smooth, easy to handle and field work.
the test method: arc reflection method, dc arc reflection method, current sampling, voltage sampling (optional), the dc output.
the sampling signal types: arc reflection method, dc arc reflection method, current sampling, voltage sampling (optional), low pressure pulse.
DC High Voltage Output:
0~32KV Negative Polarity Maximum Current Output:76mA 0~16KV Negative Polarity Maximum Current Output:152mA 0~8KV Negative Polarity Maximum Current Output:304mA
Impact capacitance :
0~32KV 4μF Maximum output power 2048J 0~16KV 16μF Maximum output power 2048J 0~8KV 64μF Maximum output power 2048J
the ball discharge gap: the weak current control, adjustable discharge period of 3 to 12 seconds, and special design quieter, meet the requirements of head cable fault need to mute.
protection: position of zero voltage protection: to prevent wrong operation, to ensure the safety of person and the subjects; According to "disconnect" button after, through the internal safety device, will release the remaining charge automatically, and ensure safety.
matching extension cable, shall constitute a vehicle type cable fault location system.
Capacitance
charging voltage
PRODUCT
8KV
16KV
32KV
Capacitance
impact energy
Capacitance
impact energy
Capacitance
impact energy
HZ-4000T2
64μF
2048J
16μF
2048J
4μF
204
Product Details
Certifications
We have our own manufacturing factory,pls see the below certificate,we are the direct supplier.
We are a new enterprise engaged in development,produce & sale a serious of power system products, such as Cable fault tester, transformer test class, lightning arrester test class, comprehensive test class.
Our Workshop
Exhibition
Contact
No desirable products?
Sourcing assistant>
How to start your business
Step 1
Find your interested products by search keywords
Step 2
Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
Step 3
After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
Step 4
Set up meeting with the Chinese supplier without language barrier