Applications:
1) High precision distance measuring;
2) Obstacle-avoidance, automatic control;
3) Objects close to, exist, perceive;
4) Traffic control;
5) Security and protection, industrial control;
6) Artificial intelligence, teaching and research;
Electrical Parameters:
Item | PWM output | UART output | Digital Output |
Supply Voltage | DC3.3V – 12V, ripple wave is less than 100mV | ||
Standby Current | Less than 100uA | Less than 400uA | |
Operating Current | Supply voltage is 5V, cycle is 250ms, average current is 2mA | ||
Center Frequency | 40KHz | ||
Blind Zone | 250mm | ||
Start Detection | Need to subtract 40mm (the distance from surface of ultrasonic transducer to the plane of horn mouth) | ||
Max. Detection Distance | More than 8m | ||
Emission Angle | 8 degree | ||
Work Cycle | More than 60ms | 250ms | |
Trigger Signal | Falling Edge Trigger | GND connection | |
Test Precision | ±1cm+(S*0.3%), S is the measured value | ||
Resolution of Ranging | 1mm | ||
Temperature Compensation | None | Have | |
Temperature | None | Have | None |
Operating Temperature | -15℃ to +60℃ | ||
Storage Temperature | -25℃ to +80℃ |