The EN series is a diaphragm dosing pump which consists of a pump head, a driving unit, and a control unit. A diaphragm is directly driven by electromagnetic force.
Principle of operation
Control unit send the 4-20MA signal to drive unit. The 4-20mA signal controls the electromagnetic force and spring force in order to make reciprocating motion .The reciprocationg motion is transferred to a disphragm through a plunger and then volumetric change occurs in the pump head. The action transfers liquid along with pump head value action.