1.Place the T962 on an appropriate level, insulated work area.
2. Make Sure the work space is well ventilated (exhaust fans may be necessary).
3. Allow at least 20mm between the T962 and its surroundings for heat protection.
4. Confirm the Work drawer opens and closes smoothly and without obstruction.
5. Locate supplied universal power cord and connect same from rear apron to AC power.
6. Locate and press the power on button, the LCD will light, the T962 will log on,
- Press "s" button go to main menu page,
- Press "F4" button, change to English Menu,
- In the main menu,Press "F3" button selection different temperature wave,
- Press "F3" button again,can see parameter about you choose the temperature wave: soldering paster sort. soldering temperature,
- Press "F4" button to return previous page, Press the temperature wave that the"F1" key carries out to make selection automatically, The work shuts down automatically after end,warning buzzer is working,
- In the main menu page,press " F2"button by handcraft operation,
- Press "F1" button to start cooling, Press F1/S key again to stop. Press "F2" button to strat heat up, Press F2/S key again to stop.
Select the Wave:
1.Press the "S"button selection operation interface after switch on, press the "F4" selections a different language category.
2. Process to request to set the wave comparison according to you to provide you with the reference.Press the F1/F2 choices different wave, there have 8 kinds of different temperature waves can provide you with the choice, press F3 to look into different wave parameter, press 4 confirm wave.
- Wave one, use the same with 85Sn/15Pb 70 Sn/30Pb
- Wave two, use the same with 63Sn/37Pb 60 Sn/40Pb
- Wave three, use the same with Sn/Ag3.5; Sn/Cu 75 Sn/Ag4.0/Cu.5
- Wave four, use the same with Sn/Ag2.5/Cu.8/Sb.5; Sn/Bi3.0/Ag3.0
- Wave five, use the same with The red gum standard is solid to turn temperature wave,Heraeus PD955M.
- Wave six,seven,eight, use the same with The PCB circuit board returns to fix etc.
- Press "s" button to the temperature page,
- Press "s" button to the temperature page,
- Press F1/F2 button,ahead/ backwards select different time.
- Press F3/F4 button ,up/down to select different temperature,Press "s" button to save.When save finish ,press F4 button to select the temperature wave.Press S button to repetition.
Operating Instructions:
1.The product that will process lightly puts into the even on the stage in the drawer, Close drawer, Press F1 to switch on, The automatic performance make selection of heat wave, Show current performance time,the enactment temperature and measure temperature on the LCD screen, and the automatic formation order form wave.
2. Observed the data,wave of the window and the LCD screen manifestation before passing drawer, in the whole supervision that processed all of process and can see at you, if the request for processing wave to could not reach you can modification parameter.
3. Process the wave is strict to press the different tin syrup different temperature to have pre-established request to the return solder , you can prepare to establish another wave according to the different need.
4.Process process in, if need stop, can press "S" to carry on to terminate compulsory;After put the last hand, the breeze machine auto carries on cooling to the product;You can also start the breeze machine to carry on cooling compulsory.
5. After returning solder completion, If the product existence blemish.can solder again, Can also move the start heating to carry on returning to solder. This machine establishes this function.
Operation Suggests:
1. The this aircraft for satisfies without the lead double-sided welding, the design has the unique air flue, for the guarantee platelet welding request, suggested when the welding platelet and BGA plant the tin ball, pulls out the base in the material to put in advance one 10 x 10cm PCB board, may cause the welding quality to be better.
2.The ambient temperature is low when, the humidity or the humidity too are big, suggested before the welding wants preheating the machine.The operating procedure is: After chooses the welding curve, spatial machine returns automatically welds one time.
3. The this aircraft cannot weld the counter-optical too strong metal seal chip and the metal screening can; May not weld the withstanding temperature to be lower than 250 degree plastic plug-in units and the goods, asks respectfully the attention!
4.Customer examination machine temperature method: Uses the standard thermometer, outside will set at the temperature probe head fixedly 10 x 10cm PCB stiff surface, shuts tight certainly importantly in the PCB board above! Will fix has the temperature measurement probe head PCB board, puts in the material to pull out, thrusts in the machine, like this tests the temperature comparison conforms to the product production actual situation.
Daily Maintenance:
1.Keep the drawer.
2..Periodically sweep the observation bore glass of the drawer, keep it to sweep.
Caution:
1.After use,Don't at once close the power,make sure the machine cooling .
2.assure well ventilated of the machine.
3.Disconnect the plug when you don't use the it for a long time.
4.Don't open the machine ,take care carefully to use.
Details: