Enquiries
Message
Home > Products > Other
Laboratory Transformer Oil Dissolved Gas Analysis equipment FID TCD Gas Chromatography
  • Laboratory Transformer Oil Dissolved Gas Analysis equipment FID TCD Gas Chromatography

Laboratory Transformer Oil Dissolved Gas Analysis equipment FID TCD Gas Chromatography

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Warranty:
one year warranty and long life maintenance, 1 Year
Customized support:
OEM
Place of Origin:
Hebei, China
Brand Name:
PUSH
Product Name:
Transformer Oil Dissolved Gas Analyzer
Test Method:
gas chromatography
Temperature control area:
6 channels
Temperature programmed order:
16 order
External events:
4 channels
The number of detectors:
4; FID, TCD, ECD, FPD (optional)
Start sampling:
manual and automatic selection
Communication interface:
Ethernet: IEEE802.3
dissolved gas:
7gas, or 9gas
Certification:
Calibration Certificate, ISO
Supply Ability
Supply Ability:
100 Set/Sets per Month
Packaging & Delivery
Product Description
Laboratory Transformer Oil Dissolved Gas Analysis equipment FID TCD Gas Chromatography

 

The gas chromatograph is composed of a sampling device, a detector, a chromatographic column box, a gas flow control system, a circuit control detection system and an optional special workstation. Optional FID, TCD, ECD, FPD and other detectors. It can be widely used in the quality control and product testing in the fields of chemical, pharmaceutical, food and so on.

 

Functions and characteristics
1: using the advanced technology of 10/100M adaptive Ethernet communication interface, and the built-in IP protocol stack, the instrument can easily through the intranet and the Internet to realize remote data transmission; convenient laboratory installation, simplified laboratory configuration and convenient data management.
2: Design 3 independent connection process inside the instrument, can be connected to the local processing (Laboratory), director of the unit (such as quality inspection, production director and chief), and Supervisor (such as environmental protection bureau, bureau of technical supervision, etc.) can conveniently make the unit supervisor and the supervisor of real-time monitoring instrument operation and analysis the results of data.
3: instrument selected NetChromTM workstation can support multiple chromatograph work, realize data processing and control, simplify document management, and reduce user's laboratory investment and operation cost to the greatest extent.
4: the system has a Chinese and English operating system, and users can switch on their own according to their needs.
5: the temperature control area can be named freely by the user, which is convenient for the user to use.
6: the instrument adopts multi processor parallel operation mode, making the instrument more stable and reliable. It can meet the analysis of complex samples, and can choose a variety of high-performance detectors, such as FID, TCD, ECD and FPD, which can install four detectors at the same time. It is also possible to select and install other detectors after the purchase of the instrument by the addition of detector.
7: the instrument adopts the modular structure, the design is clear, the replacement and upgrade are convenient, and the efficiency of the investment is protected.
8: new microcomputer temperature control system, temperature control precision, reliability and anti-jamming performance; temperature control system with six completely independent, can realize the sixteen step temperature programming, analysis the equipment for a greater range of samples; with column box automatically after the door system, the temperature control precision is improved. Heating / cooling speed.
9: instrument is equipped with advanced electronic flow controller (EFC) and electronic pressure controller (EPC) to achieve digital control, which can greatly improve the reproducibility of qualitative and quantitative results.
10: the device is designed to be self starting program. It can easily complete the on-line analysis of gas samples (equipped with on-line automatic sampling components).
11: the operation system of the keyboard is controlled by the whole computer, the operation is simple and convenient, and the automatic identification technique of the detector is designed. With the function of fault diagnosis and power failure data protection, the parameters can be automatically memorize.
12: the instrument has a 24 bit AD circuit with low noise and high resolution, and has the function of base line storage and baseline deduction.
13: acquisition of chromatographic signal and data processing, suitable for WinXP, Win2000, Windows7 and other operating systems. The CDF file, which meets the standard of A/A (American Analysis Society), reads the sample data, so it can be used to track the chromatogram workstations such as Agilent and Waters.
15: the chromatographic system with complete independent intellectual property rights has the standard interface of MODBUS/TCP and can be conveniently butted with DCS.
16: the instrument can be connected with the automatic sampler produced by many manufacturers at home and abroad, such as SHIMADZU AOC-20i, HT series efficient liquid and gas automatic injector of Italy HTA company.

 

The main technical indicators:
• operating display: 5.7 inch periodic lattice Chinesize color liquid crystal
  (can be equipped with touch screen)
• temperature control area: 6 ways
• temperature: room temperature above 5 ℃ ~ 400 ℃, incremental:1 ℃, accuracy :± 0.1 ℃
• temperature-programmed order: 16 order
• Temperature program rate: 0.1 ~ 39 ℃ /min (common type); 0.1 ~ 80 ℃ /min (high speed)
• the gas control: optional pressure flow control mode of the mechanical valve control mode, electronic
• gas pressure, flow measurement: pointer type pressure meter or electronic pressure, flow pattern
• all electronic gas pressure, flow measurement system
  The single module maximum measuring way: 16
  Range: 0 ~ 0.3MPa (pressure); 0 ~ 500sccm (flow)
  Resolution: 0.01kPa (pressure); 0.01sccm (flow)
• EPC, EFC work mode: 3kinds:constant current mode, constant voltage mode, bypass mode
• EPC, EFC working gas: 4kinds:nitrogen, air, hydrogen, helium, argon
• EPC, EFC L: 4 order
  EPC, EFC: pressure control range: 0 ~ 0.6MPa; flow rate of 0 ~ 100sccm or 0 ~ 500sccm (air);
• EPC, EFC control precision pressure 0.01kPa; flow rate: 0.01sccm;
• external events: 4 road, 4 road; auxiliary control output
• injector types: packed column sample, the capillary inlet, six valve gas sampling, automatic headspace       sampling.
• detector number: 3 (up); FID, TCD, ECD, FPD and NPD.
• start sampling: manual, automatic optional
• communication interface: Ethernet: IEEE802.3

 

Detector technology index
Hydrogen flame ionization detector (FID)
•The limit of detection: ≤ 1×10-11g/s (sixteen alkyl);
• baseline noise: ≤5×10-14A
• baseline drift: ≤1×10-13A/30min
• linear range:≥106
Thermal conductivity detector (TCD)
• sensitivity: S ≥ 2500mV•ml/mg (sixteen alkyl) (1, 2, 4, 8 times enlarged ,optional.)
• baseline noise: ≤ 20 μ V
• baseline drift: ≤ 30 μ V/30min
• linear range:≥104
Electron capture detector (ECD)
•The limit of detection: ≤ 1×10-13g/ml(C 666 - isooctane solution)
• baseline noise: ≤ 0.03mV
• baseline drift: ≤ 0.2mV/30min
• linear range: 103
• source: 63Ni
Flame photometric detector (FPD)
•The limit of detection: (S) ≤5×10-11g/s, (P) ≤1×10-12g/s; methyl parathion - ethanol solution)
• baseline noise: ≤ 3×10-13A
• baseline drift: ≤2×10-12A/30min
• linear range: To sulfur≥102, To P ≥103

 

Details and Accessories

 

Packaging & Shipping

Company Information

Laboratory Transformer Oil Dissolved Gas Analysis equipment FID TCD Gas Chromatography from China supplier

Contact us

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher