Features:
* Universal AC input / Full range
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Built-in active PFC function
* High efficiency up to 91%
* Cooling by free air convection
* Optional dimming function (1~10Vdc .or PWM signal .or resister)
* Suitable for LED lighting and moving sign applications
* Compliance to worldwide safety regulations for lighting
* Suitable for dry / damp locations
* Fully isolated plastic case
* Epoxy encapsulated with IP67 level
* Class 2 power unit
* 3 years warranty
Specifications:
MODEL |
LPF-60-12 |
LPF-60-15 |
LPF-60-20 |
LPF-60-24 |
LPF-60-30 |
LPF-60-36 |
LPF-60-42 |
LPF-60-48 |
LPF-60-54 |
|
OUTPUT |
DC VOLTAGE |
12V |
15V |
20V |
24V |
30V |
36V |
42V |
48V |
54V |
CONSTANT CURRENT REGION Note.4 |
7.2 ~12V |
9 ~ 15V |
12 ~ 20V |
14.4~ 24V |
18 ~ 30V |
21.6~ 36V |
25.2~ 42V |
28.8~ 48V |
32.4~ 54V |
|
RATED CURRENT |
5A |
4A |
3A |
2.5A |
2A |
1.67A |
1.43A |
1.25A |
1.12A |
|
RATED POWER |
60W |
60W |
60W |
60W |
60W |
60.12W |
60.06W |
60W |
60.48W |
|
RIPPLE & NOISE (max.)? Note.2 |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
250mVp-p |
250mVp-p |
250mVp-p |
350mVp-p |
|
VOLTAGE TOLERANCE?? Note.3 |
4.0% |
4.0% |
4.0% |
4.0% |
4.0% |
4.0% |
4.0% |
4.0% |
4.0% |
|
LINE REGULATION |
0.5% |
0.5% |
0.5% |
0.5% |
0.5% |
0.5% |
0.5% |
0.5% |
0.5% |
|
LOAD REGULATION |
2.0% |
2.0% |
1.5% |
1.0% |
0.5% |
0.5% |
0.5% |
0.5% |
0.5% |
|
SETUP, RISE TIME |
1000ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC |
|||||||||
HOLD UP TIME (Typ.) |
16ms at full load 230VAC /115VAC |
|||||||||
INPUT |
VOLTAGE RANGE |
90 ~ 305VAC 127 ~ 431VDC |
||||||||
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||||
POWER FACTOR |
PF 0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load |
|||||||||
EFFICIENCY (Typ.) |
86% |
87% |
88% |
89% |
90% |
90% |
91% |
91% |
91% |
|
AC CURRENT (Typ.) |
0.8A / 115VAC 0.4A / 230VAC |
|||||||||
INRUSH CURRENT (Typ.) |
COLD START 75A/230VAC |
|||||||||
LEAKAGE CURRENT |
<0.75mA / 240VAC |
|||||||||
PROTECTION |
OVERCURRENT |
95 ~ 108% |
||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||||||||
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed. |
|||||||||
OVER VOLTAGE |
14 ~ 16V |
17.5 ~ 21V |
23 ~ 27V |
28 ~ 35V |
34 ~ 38V |
41 ~ 49V |
46 ~ 54V |
54 ~ 63V |
59 ~ 65V |
|
Protection type : Shut down o/p voltage with auto-recovery .or re-power on to recovery |
||||||||||
OVER TEMPERATURE |
105? 10 (RTH2) |
|||||||||
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +50 @ full load ; +70 @ 60% load (Refer to derating curve)? ; -40 can power on |
||||||||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +80 , 10 ~ 95% RH |
|||||||||
TEMP. COEFFICIENT |
0.03%/ (0 ~ 50 ) |
|||||||||
VIBRATION |
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
|||||||||
SAFETY &EMC(Note 4) |
SAFETY STANDARDS |
UL8750, EN61347-1, EN61347-2-13 independent, IP67 approved ; Design refer to UL60950-1, TUV EN60950-1 |
||||||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC |
|||||||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH |
|||||||||
EMI CONDUCTION & RADIATION |
Compliance to EN55015, Class B |
|||||||||
HARMONIC CURRENT |
Compliance to EN61000-3-2,CLASS C( 60% load),EN61000-3-3 |
|||||||||
EMS |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level, criteria A |
|||||||||
OTHERS |
MTBF |
Khrs min. MIL-HDBK-217F (25 ) |
||||||||
DIMENSION |
162.5*42.5*32mm (L*W*H) |
|||||||||
PACKING |
Kg; 32pcs/ Kg/0.56CUFT |