Compact Constant mode output
Plastic housing with Class II design
Built-in active PFC function
Class 2 power unitcv
Fully encapsulated with IP30 level optional IP67 rating
Function: 3 in1 dimming
Typical lifetime>50000 hours
5 years warrant
LPF-40D-12 | LPF-40D-15 | LPF-40D-20 | LPF-40D-24 | LPF-40D-30 | LPF-40D-36 | LPF-40D-42 | LPF-40D-48 | LPF-40D-54 | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V | |||
RATED CURRENT | 3.34A | 2.67A | 2A | 1.67A | 1.34A | 1.12A | 0.96A | 0.84A | 0.76A | ||||
RATED POWER Note.5 | 40.08W | 40.08W | 40W | 40.08W | 40.2W | 40.32W | 40.32W | 40.32W | 41.04W | ||||
CONSTANT CURRENT REGION Note.2 | 7.2 ~12V | 9 ~ 15V | 12 ~ 20V | 14.4 ~ 24V | 18 ~ 30V | 21.6 ~ 36V | 25.2 ~ 42V | 28.8 ~ 48V | 32.4 ~ 54V | ||||
CURRENT RIPPLE | 5.0% max. @rated current | ||||||||||||
CURRENT TOLERANCE | ±5.0% | ||||||||||||
SETUP, RISE TIME Note.6 | 1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC | ||||||||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC | ||||||||||||
INPUT | VOLTAGE RANGE Note.5 | 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" ) |
|||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||
POWER FACTOR (Typ.) | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) |
||||||||||||
TOTALHARMONIC DISTORTION | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) (Please refer to “TOTALHARMONIC DISTORTION(THD)” section) |
||||||||||||
EFFICIENCY (Typ.) Note.10 | 84% | 85% | 86% | 87% | 88% | 88% | 88.5% | 89% | 89% | ||||
AC CURRENT | 0.6A/ 115VAC 0.3A/ 230VAC 0.25A/277VAC | ||||||||||||
INRUSH CURRENT (Typ.) | COLD START 50A(twidth= s measured at 50% Ipeak) at 230VAC 210μ ; Per NEMA410 | ||||||||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER |
12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | ||||||||||||
LEAKAGE CURRENT | <0.75mA/ 240VAC |