Application
Based on Windows operating system, the human-machine interface is good; standard SA905 optical interface, CCD high-speed spectrum; can be directly connected to the printer to print test reports, Excel saves data, which is conducive to analysis; a host configuration related device, fully meets the light source color of the light source Performance testing and analysis and other related tests. It is suitable for R&D testing in laboratories and quality inspection departments, and can also be used for rapid testing of production lines.
Characteristic
Good man-machine exchange interface based on Windows operating system;Standard SMA905 optical fiber interface, CCD high-speed spectrum;High precision, fast test, easy to use;Connect to printer to print test report, Excel to save data for analysis;A host machine is equipped with related devices, which can fully meet the requirements of various performance tests and analyses of the light source.It is suitable for research and development test of laboratory and quality control department, and also for fast test of production line.
Performance parameter:
Measure LED spectral power distribution, color coordinate, color temperature, color rendering index, color temperature difference, peak wavelength, half spectral width, main wavelength, color purity, luminous flux, irradiance, luminous efficiency, forward voltage, reverse leakage current and other optical color electrical performance parameters;
high intellectualization of the instrument, high test stability, high repeatability, fully meet the CIE requirements for light and color measurement;
XP2000S LED rapid spectral analysis system configuration list
Number |
Product Name |
Specifications and models |
Product use |
Remark |
01 |
Fast spectrum analyzer |
HP8000Z |
Test the light - color - electrical properties of the light source(380nm~780nm) |
(380nm~780nm) |
02 |
Conductive fiber |
1.5m |
Used for the transmission of optical signal between integrating sphere and HP series spectral analysis system |
Double Optical fiber |
03 |
Standard light source |
24V/50W |
OSRAM |
|
|
Standard light source |
10W/6V |
Used for calibration of color and luminous flux |
OSRAM |
04 |
Precision integrating sphere |
0.3m |
Used for single LED and COB test |
Side opening |
|
Precision integrating sphere |
2m |
Provide a good test environment for the whole lamp to be tested, avoid light pollution and loss of light source |
Test the whole lamp |
05 |
Electrical parameter measuring instrument |
HP104 |
Monitor the voltage, current, power, power factor/frequency of the light source |
Ac/dc mode |
06 |
AC variable frequency power supply |
VHP500 |
Provide a stable working condition for all loads under test |
Power the whole lamp (optional) |
07 |
Standard cabinets |
19 inches |
It can be placed in the company's measuring instruments, equipped with a complete set of panels; dustproof, anti-electromagnetic interference is better, in line with international trends |
(optional) |
08 |
Testing software |
HP8000S |
HP-specific Chinese and English software |
/ |
09 |
Test fixture |
3528-5730 |
Fixed LED test |
|
Specifications
Name |
Function |
Parameter scale |
speed |
Testing speed |
5ms-2s |
Optical parameter test |
Luminous flux measurement range |
10mlm~50000lm |
Photometric accuracy |
1 |
|
Wavelength Range |
380~780nm |
|
Wavelength accuracy |
±0.2nm |
|
Color parameter test |
Range of color temperature measurement |
1000K—100000K |
resolution |
1K |
|
Accuracy of color temperature |
±0.2% |
|
Color coordinate accuracy |
±0.0015 |
|
Range of color rendering index |
0-100 |
|
Color index test error |
±(0.5%rd+0.5) |
|
Color tolerance accuracy |
±0.5SDCM |
|
electrical parameter testing |
Forward current(IBFB) |
0.1mA~5000.0m A |
Forward voltage(VBFB) |
0.01V~40.00V |
|
0.1μA~200μA |
||
Inverse voltage(VBRB) |
0.01V~30.00V |
|
Measuring accuracy of electrical parameters |
0.5 |
B:2mConductive fiber
Optical signal transmission between integrating sphere and HP8000Z,spectral analysis system.
C:Standard light source
The calibrated working current has stable and reproducible color temperature (spectral distribution) and luminous flux, which are used for the calibration of color temperature (spectral distribution) and luminous flux of the spectral analysis system..
D:Measuring integral ball (special process spraying)2.0 m integral ball 0.3 m integral ball
The design fully conforms to the requirements of the corresponding international and domestic standards. The main material of the inner wall coating is pure barium sulfate (BaSO4), which has good chemical stability and is not easy to yellowing over time.The ball material is cold-rolled steel plate, which is not easy to deform.The height of the base can be adjusted to ensure the horizontal placement of integral balls;Multiple interfaces can satisfy multiple tests of light source at the same time.
5. HP104 digital electrical parameter measuring instrument (ac-dc applicable)
Technical features:
four Windows display: voltage, current, power, power factor/frequency;
all measured values are "true RMS"; Automatically set range;
with ac, dc, ac and dc measurement functions
Function |
Measurement/range |
Measuring accuracy |
Remark |
Voltage |
DC :75V/150V/300V/600V |
0.5 |
±(0.4%+0.1%+1) |
AC :35/75V/150V/300V |
0.5 |
||
Current
|
DC :0.5A/2A/8A/20A |
0.5 |
|
AC :0.3A/1.2A/5A/20A |
0.5 |
||
Power factor |
-1.000~1.000 |
0.5 |
|
Fundamental |
45Hz-130Hz,bandwidth:5KHz |
0.5 |
How to contact us?