KS800 Position Sensor Digital Readout from China Factory
1.Technical characteristic
KS800 is a six-bit displayed table for displaying displacement, which has functons of control, display, transformation, RS485 Protocol, etc.
The high counting frequency is a outstanding feature of KS800, which is up to 500KHZ.
u International size of 96×48×115mm, six-bit of 0.56 inches nixie tubes.
u Input A and input B make up two-sides input, which can recognize signal with 90°phase difference from encoder.
u There are “reset” terminal outside the table, which allows zero data.
u There are two control values in two relays, it can be used for controling or warning.
u Standars:Two relays, four kinds of relay output.( There are four relays type for choose).
u Setting the time of automatical reset-delay to use the funtion of automatical reset-delay.
u Fuction of displaying peak value.
u When power off, don’t lose current value and set value.
u Allows setting resolution.
u Connected with sensors: power sensors with 5V(100mA),12V(100mA). Accept customized power type.
u Counting doubling frequency :Quadruple frequency.
u 4-20mA output( Optional).
u RS485 Protocol. 115200bps communicating baud rate, sending display-value every 5 seconds actively.
2.Technical parameters
u Supply power: 220VAC 50Hz
u Input impedance: 5KΩ
u Pulse frequency: <500KHz
u Counting magnificaiton: 0.000 ~ 999.999
u Display-value range: -99999 ~ 999999
u Level of pulse: Low level: -50V ~ 0.5V High level: 3.5 ~ 50V
u Contact capacity: AC250V3A DC30V3A
u Installation method: Snap-in type
u Hole size: 92 × 43.5mm
u Environment temperature: -10℃~ 50℃
3.Instructions
1>Step1: Enter into the function of setting parameters.
Press ”Mo” for more than 2 seconds, the digital table display”Fn00”, and now it turn into the function of setting parameters.
2> Step 2: Select the parameters we need to set. Take “Fn04” for example.
Press “ Mo” shortly, the digital table will display “Fn00, Fn001, Fn02, ……., Fn11” in turn.
When display “Fn004”, press “En” , than come out the original figure of “Fn04”, with
the last number twinkling.
3>Step 3: Setting up the selected parameter “Fn04”
Only the twinkling number can be modified, press “Mo” to select twinkling number, than press “ ↑ “ or “ ↓ “ to rise or lower the twinling numbers. At last, press “En” to completely setup “Fn004”.
4>Step 4: Setting up other parameters.
When press “En” in step 3, the digital table is back to step 1, than set other parameters as step 2, step 3.
5>When all the parameter is completely setup, press “ RST” when the digital table display “Fn0xx” , the digital table will be ready to work now.
4.The function of peak value
In condition of working, press“↓”, the pilot lamp “ MAX” will light up, the display-value will always be peak value.
Press “↓” again, lamp “MAX” will go out, the table will exit the condtion of peak value.