Irrigation Water Treatment Plastic Disc Filter
ZYT Plastic Disc Filter has a highly efficient backwash, automatic continuous production. Low water consumption and a compact design, the system alters its backwash cycle automatically between units to ensure constant output and minimal pressure loss.
1.Technical parameters
2. Water quality
Raw water quality | Good | General | Poor | Very Poor | Tube size | ||||||||
Precision | 200μm | 100μm | 50μm | 200μm | 100μm | 50μm | 200μm | 100μm | 50μm | 200μm | 100μm | 50μm | Dimension (Look at Blueprint ) |
Model | Flow(m³/hr) | Flow (m³/hr) | Flow (m³/hr) | Flow (m³/hr) | |||||||||
AD2-3 | 75 | 60 | 42 | 57 | 45 | 33 | 40 | 30 | 22 | 24 | 19 | 13 | DN100 |
AD2-4 | 100 | 80 | 56 | 75 | 60 | 44 | 54 | 40 | 30 | 32 | 26 | 18 | DN100 |
AD2-5 | 125 | 100 | 60 | 95 | 75 | 55 | 67 | 50 | 37 | 40 | 32 | 22 | DN150 |
AD3-3 | ≤111 | ≤90 | ≤60 | ≤84 | ≤66 | ≤48 | ≤60 | ≤45 | ≤33 | ≤36 | ≤28 | ≤19 | DN150/DN200 |
AD3-4 | 148 | 120 | 80 | 112 | 88 | 64 | 80 | 60 | 44 | 48 | 37 | 26 | DN150/DN200 |
AD3-5 | 185 | 150 | 100 | 140 | 110 | 80 | 100 | 75 | 55 | 60 | 47 | 32 | DN150/DN200 |
AD3-6 | 222 | 180 | 120 | 168 | 132 | 96 | 120 | 90 | 66 | 75 | 56 | 39 | DN150/DN200 |
AD3-7 | 259 | 210 | 140 | 196 | 154 | 112 | 140 | 105 | 77 | 84 | 66 | 45 | DN150/DN200 |
AD3-8 | 296 | 240 | 160 | 224 | 176 | 128 | 160 | 120 | 88 | 96 | 75 | 52 | DN150/DN200 |
AD3-9 | 333 | 270 | 180 | 252 | 198 | 144 | 180 | 135 | 99 | 108 | 85 | 58 | DN200 |
AD3-10 | 370 | 300 | 200 | 280 | 210 | 160 | 200 | 150 | 110 | 120 | 94 | 65 | DN200 |
3. ADC Controller
It is designed for disc filter, and controlled by a microcomputer controller and a pressure signal distributor, and fixed in the IP65 waterproof box.
Microcomputer program controller can be sent to start time interval, the differential pressure signal of startup, external mandatory start signal control methods to control the filter backwashing function.
Pressure signal distributor is a dominated by rotary pilot valve guiding the liquid or gas pressure source. By switching the filter backwashing valve open and close it powers the systems automatic control of the filter unit in backwashing function.
Model | Control unit | Distributor | Power | Out size (mm) | Weigh (kg) | Pressure grade | |
ADC2.0-2 | 2 | 6Stations | AC220 50/60HZ AC110 50/60HZ | 400x250x200 | 2.6 | PN0.8Mpa | |
ADC2.0-3 | 3 | 6Stations | 400x250x200 | 2.6 | |||
ADC2.0-4 | 4 | 6Stations | 400x250x200 | 2.6 | |||
ADC2.0-5 | 5 | 6Stations | 400x250x200 | 2.6 | |||
ADC2.0-6 | 6 | 12Stations | 400x250x200 | 3.1 | |||
ADC2.0-7 | 7 | 12Stations | 400x250x200 | 3.1 | |||
ADC2.0-8 | 8 | 12Stations | 400x250x200 | 3.1 | |||
ADC2.0-9 | 9 | 12Stations | 400x250x200 | 3.1 | |||
ADC2.0-10 | 10 | 12Stations | 400x250x200 | 3.1 | |||
ADC2.0-11 | 11 | 12Stations | 400x250x200 | 3.1 |
Remark :Temperature 5-55℃, pleasure confirm the model when marking an order
4. Improving and Enhancing the Traditional Disc Filter
Model | Shell circle | Max wide | Height | Weight (Kg) | Material | Joint form | Optional filter disc |
AD2Unit | 230 | 265 | 701 | 8.1 | Engineer plastic | 3”coupling | Green 50μm Red 100μm Yellow 200μm |
AD3Unit | 230 | 265 | 885 | 9.4 |
5. Project References
6. Applications
Agriculture irrigation, landscape irrigation, golf course irrigation, industrial dust, etc.