Model | AW60 | AW68 | AW80 | AW100 | ||||||||
Cooling mode | ||||||||||||
Cooling capacity | kW | 58.2 | 66 | 84 | 100.1 | |||||||
Input | kW | 19.9 | 23.3 | 30.5 | 35 | |||||||
EER | / | 2.92 | 3.25 | 3.23 | 2.86 | |||||||
Energy class full load operation | / | B | A | A | B | |||||||
ESEER | / | 4 | 4.41 | 4.42 | 4.35 | |||||||
Seasonal energy efficiency ratio SEER | / | 4.2 | 4.28 | 4.33 | 4.2 | |||||||
Season energy efficiency ɳs,c | % | 165 | 168 | 169 | 168 | |||||||
Seasonal energy performance ratio SEER SEPR-high temperature(7°C) | / | 5.6 | 5.64 | 5.64 | 5.62 | |||||||
Seasonal energy performance ratio SEER SEPR-medium temperature(-8°C) | / | 3.44 | 3.54 | 3.56 | 3.39 | |||||||
Heating mode | ||||||||||||
Rated heating capacity | kW | 62 | 70 | 90 | 106.3 | |||||||
Input | kW | 20.6 | 21.1 | 26 | 34 | |||||||
COP | / | 3 | 3.31 | 3.46 | 3.12 | |||||||
Energy class full load operation | / | B | B | B | A | |||||||
Seasonal coefficient of performance SCOP | / | 3.5 | 3.45 | 3.35 | 3.45 | |||||||
Seasonal energy efficiency | % | 126 | 133 | 135 | 133 | |||||||
Seasonal energy efficiency class | / | A+ | ||||||||||
Electrical data | Voltage | / | 380-415V/3ph/50Hz | |||||||||
Compressor | Type | / | Fixed scroll | |||||||||
Refrigeration circuit and compressor number | / | 4/4 | 2/2 | 2/2 | 2/2 | |||||||
Type | / | Fin-coil | ||||||||||
Fan motor type | / | AC motor | ||||||||||
Quantity of fan motor | Nr. | 2 | 2 | 2 | 2 | |||||||
Air flow | m3/h | 12000X2 | 12000X2 | 17900X2 | 19500x2 | |||||||
Type | / | Shell and tube(standard) spiral drum heat exchanger(option)/plate heat exchanger(option) | ||||||||||
Pressure drop | kPa | 43 | 43 | 42 | 41 | |||||||
Nominal Water flow rate | m3/h | 10.3 | 11.7 | 15.1 | 17.2 | |||||||
Economizer heat exchanger | / | Plate heat exchanger(option) | ||||||||||
Hydraulic connection | Type | / | Threaded-male | |||||||||
Hydraulic connection | Diameter | mm | DN65 | |||||||||
Acoustic data | Sound power level | dB(A) | 70 | 74 | 72 | 73 | ||||||
Refrigerant | Type | / | R410a | |||||||||
Charge volume | kg | 4.4x4 | 8.5x2 | 12x2 | 17x2 | |||||||
Throttle type | / | EXV | ||||||||||
Unit dimension(WxHxD) | mm | 2100x2030x1060 | ||||||||||
Packing dimension(WxHxD) | mm | 2200X2180X1120 | ||||||||||
Net/Gross weight | kg | 720/780 | 740/800 | 810/870 | 1100/1180 | |||||||
Operating limits | ||||||||||||
Cooling mode | ||||||||||||
Min outlet water temperature | oC | -12(option)/+5(standard) | ||||||||||
Max inlet water temperature | oC | 20 | ||||||||||
Min difference water inlet/outlet | oC | 3 | ||||||||||
Max difference water inlet/outlet | oC | 8 | ||||||||||
Min ambient air temperature | oC | -20(option)/+6(standard) | ||||||||||
Max ambient air temperature | oC | 46 | ||||||||||
Heating mode | ||||||||||||
Max outlet water temperature | oC | 50 | ||||||||||
Min ambient air temperature | oC | -25(option)/-12(standard) |
Model | AW130 | AW150 | AW200 | AW240 | AW260 | |||||||||
Cooling mode | ||||||||||||||
Cooling capacity | kW | 120.5 | 148.2 | 199 | 236 | 266 | ||||||||
Input | kW | 39 | 53.9 | 71 | 83.6 | 82 | ||||||||
EER | / | 3.08 | 2.74 | 2.8 | 2.82 | 3.24 | ||||||||
Energy class full load operation | / | B | A | C | C | A | ||||||||
ESEER | / | 4.16 | 4.37 | 3.76 | 3.98 | 4.16 | ||||||||
Comfort application | Seasonal energy efficiency ratio SEER | / | 4.19 | 4.25 | 3.82 | 3.92 | 4.23 | |||||||
Season energy efficiency ɳs,c | % | 161 | 166 | 149 | 154 | 166 | ||||||||
Process application | Seasonal energy performance ratio SEER SEPR-high temperature(7°C) | / | 5.64 | 5.4 | 4.8 | 5.06 | 5.25 | |||||||
Seasonal energy performance ratio SEER SEPR-medium temperature(-8°C) | / | 3.56 | 3.33 | 3.66 | 3.32 | 3.23 | ||||||||
Heating mode | ||||||||||||||
Rated heating capacity | kW | 136 | 158 | 206 | 253 | 296 | ||||||||
Input | kW | 43.4 | 51.6 | 72 | 78.3 | 96 | ||||||||
COP | / | 3.13 | 3.06 | 2.86 | 3.23 | 3.08 | ||||||||
Energy class full load operation | / | A | B | A | A | A | ||||||||
Seasonal coefficient of performance SCOP | / | 3.38 | 3.4 | 3.23 | 3.7 | 3.39 | ||||||||
Seasonal energy efficiency | % | 132 | 133 | 126 | 145 | 132 | ||||||||
Seasonal energy efficiency class | / | A+ | ||||||||||||
Electrical data | Voltage | / | 380-415V/3ph/50Hz | |||||||||||
Compressor | Type | / | Fixed scroll | |||||||||||
Refrigeration circuit and compressor number | / | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | ||||||||
Air side heat exchanger | Type | / | Fin-coil | |||||||||||
Fan motor type | / | AC motor | ||||||||||||
Quantity of fan motor | Nr. | 4 | 4 | 4 | 4 | 4 | ||||||||
Air flow | m3/h | 12600x4 | 15600x4 | 24000x4 | 24000x4 | 24000x4 | ||||||||
Water side heat exchanger | Type | / | Shell and tube(standard) spiral drum heat exchanger(option)/plate heat exchanger(option) | |||||||||||
Pressure drop | kPa | 44 | 45 | 45 | 46 | 55 | ||||||||
Nominal Water flow rate | m3/h | 23 | 26 | 35 | 41 | 46 | ||||||||
Economizer heat exchanger | / | Plate heat exchanger(option) | ||||||||||||
Hydraulic connection | Type | / | Threaded-male | |||||||||||
Diameter | mm | DN80 | DN80 | DN65 | DN65 | DN80 | ||||||||
Acoustic data | Sound power level | dB(A) | 77 | 77 | 75 | 75 | 75 | |||||||
Sound pressure level 10meters | dB(A) | 57 | 57 | 55 | 55 | 55 | ||||||||
Refrigerant | Type | / | R410a | |||||||||||
Charge volume | kg | 8.5x4 | 12x4 | 17x4 | 20x4 | 22x4 | ||||||||
Throttle type | / | EXV | ||||||||||||
Unit dimension(WxHxD) | mm | 2308x2160x2240 | ||||||||||||
Packing dimension(WxHxD) | mm | 2350x2200x2200 | ||||||||||||
Net/Gross weight | kg | 1400/1440 | 1500/1540 | 1900/1950 | 2000/2050 | 2150/2200 | ||||||||
Operating limits | ||||||||||||||
Cooling mode | ||||||||||||||
Min outlet water temperature | oC | -12(option)/+5(standard) | ||||||||||||
Max inlet water temperature | oC | 20 | ||||||||||||
Min difference water inlet/outlet | oC | 3 | ||||||||||||
Max difference water inlet/outlet | oC | 8 | ||||||||||||
Min ambient air temperature | oC | -20(option)/+6(standard) | ||||||||||||
Max ambient air temperature | oC | 46 | ||||||||||||
Heating mode | ||||||||||||||
Max outlet water temperature | oC | 50 | ||||||||||||
Min ambient air temperature | oC | -25(option)/-12(standard) |