Power supply | DC10-30V | ||
working environment | -30℃~60℃; Relative humidity 10%~9%RH | ||
Charging time | ≤4h | ||
Negative oxygen ion parameters | Measuring range | 0-5 million pcs/cm3 | |
Minimum resolution | 10pcs/cm3 | ||
Measurement error | ±15% | ||
Data update frequency | 1Hz | ||
Ion mobility | 0.4cm2/(V*S) | ||
Ion mobility error | ±5% | ||
Temperature | Measuring range | -40℃~60℃ | |
Accuracy | ±0.5℃(25℃) | ||
Resolution | ≤0.1℃/y | ||
Measuring range | 0%RH-100%RH | ||
Accuracy | ±3%RH(60%RH,25℃) | ||
Resolution | ≤1%RH/y | ||
PM10/PM2.5 | Measuring range | 0~1000ug/m3 | |
Accuracy | ±10%(25℃) | ||
Resolution | 1ug/m3 | ||
Measuring range | 0~5ppm | ||
Accuracy | ±5%FS | ||
Resolution | 0.01ppm | ||
Measuring range | 0~60000ppb | ||
Accuracy | ±8%FS±125ppb | ||
Resolution | 1ppb |
Thread color | Description | |
brown | Power is positive | |
black | Power negative | |
green | 485-A | |
blue | 485-B |