Industrial Inline Reverse Osmosis Controller CCT-8320 for RO Control
♦ Part one: Frotec Conductivity Controller Description
1.Brief introduction and Technical Specification
CCT-3300 Series Conductivity Transmitting Controller
Model |
CCT-3301E |
CCT-3300E |
CCT-3310E |
CCT-3320E |
CCT-3320/3320T |
Power supply |
DC12V±1V |
DC24V±4V |
AC 110±10% |
AC 220±10% |
AC 220±10% |
Conductivity Cell constant |
0.10;1.00;5.00(cm) |
||||
Measurement Range |
Conductivity |
0.5μS/cm~10.00mS/cm |
|||
TDS |
0.25ppm~5.00ppt |
||||
Temp. |
0~50℃(Temp.compensation component:NTC10K) |
||||
Resolution |
Conductivity |
0.01μS /cm;0.01mS/cm |
|||
TDS |
0.01ppm |
||||
Temp. |
0.1℃ |
||||
Accuracy |
Conductivity |
1.5%(FS) |
|||
Resistivity |
1.5%(FS) |
||||
TDS |
1.5%(FS) |
||||
Temp. |
±0.5℃ |
||||
(4~20) mA |
Channels |
Single channel,isolated |
|||
Characteristics |
Reversible, fully adjustable, instrument / transmitter mode for selection |
||||
Loop resistance |
400Ω(max), DC24V; |
||||
Accuracy |
±0.1mA |
||||
Control contacts |
Channels |
Single channel |
|||
Relay contacts |
SPDT |
||||
Load capacity |
AC 220V/3A Max;AC 110V/5A Max;DC 24V/3A Max |
||||
Work Environment |
Temp:0~50℃, relative humidity:≤85%RH,(none condensation) |
||||
Storage Environment |
Temp:(-20~60)℃;relative humidity:≤85%RH(none condensation) |
||||
Dimensions |
48 mm×96mm×80 mm (H×W×D) |
||||
Hole size |
44(H)mm×92(W)mm |
||||
Installation |
Panel mounted,fast installation |
CCT-5300 Series Conductivity Transmitting Controller
Model |
CCT-5300E |
CCT-5310E |
CCT-5320E |
CCT-5320 |
Power supply |
DC24V±4V |
AC 110±10% |
AC 220±10% |
AC 220±10% |
Conductivity Cell constant |
0.10;1.00;5.00(cm-1) |
|||
Measurement Range |
Conductivity |
0.5μS /cm~10.00mS /cm |
||
TDS |
0.25ppm~5.00ppt |
|||
Temp. |
0~50℃(Temp.compensation component:NTC10K) |
|||
Resolution |
Conductivity |
0.01μS /cm;0.01mS/cm |
||
TDS |
0.01ppm |
|||
Temp. |
0.1℃ |
|||
Accuracy |
Conductivity |
1.5%(FS) |
||
TDS |
1.5%(FS) |
|||
Temp. |
±0.8℃ |
|||
Temp.compensation range |
0~50℃(with25℃ as standard) |
|||
(4~20) mA |
Channels |
Single channel,isolated |
||
Characteristics |
Reversible, fully adjustable, instrument / transmitter mode for selection |
|||
Loop resistance |
400Ω(max), DC24V; |
|||
Accuracy |
±0.1mA |
|||
Control contacts |
Channels |
Single channel |
||
Relay contacts |
SPDT |
|||
Load capacity |
AC 220V/3A Max;AC 110V/5A Max;DC 24V/3A Max |
|||
Work Environment |
Temp:0~50℃, relative humidity:≤85%RH,(none condensation) |
|||
Storage Environment |
Temp:(-20~60)℃;relative humidity:≤85%RH(none condensation) |
|||
Dimensions |
96 mm×96mm×105 mm (H×W×D) |
|||
Hole size |
91mm×91mm (H×W) |
|||
Installation |
Panel mounted,fast installation |
CCT-7320 SINGLE STAGE SINGLE CHANNEL RO CONTROLLER
Basic order units
CCT-7320 Single Stage RO Controller
Conductivity cell selection:
Conductivity cell constant |
Part no. |
1.0cm-1 |
CON2134-13 |
1.0cm-1 |
CON1134-13 |
Note: CON1134-13 can’t be used for food, beverage,
medical or sanitary industries.
Note: the range of 20/ 200/2000μS /cm is fixed which can not be changed at field once set by manufacturer.
CCT-8320 Single Stage Double Channels RO Controller
Model |
CCT-8320 |
|||
Signal detection(seven channels) |
Dry contact input |
Raw water tank level:double channels |
Low level |
|
High level |
||||
Pure water tank level:double channels |
Low level |
|||
High level |
||||
Low pressure protection |
||||
High pressure protection |
||||
Pretreatment backwash signal |
||||
Control port(five channels) |
Dry contact output |
|
|
|
Raw water pump |
SPST-NO; |
|||
lnlet valve |
||||
High pressure pump |
||||
Flush vavle |
||||
Conductivity voerlimit drainge valve |
||||
Measure detection points |
Raw water conductivity,product water conductivity,raw water Temp. |
|||
Measurement range |
Raw water conductivity |
Measurement range |
5~4000μS /cm |
|
Conductivity Cell constant |
1.0cm-1 |
|||
Product water conductivity |
Measurement range |
2~200μS /cm |
||
Conductivity Cell constant |
1.0cm-1 |
|||
Medium Temp. |
0~50℃ |
|||
Accuracy |
1.5%(FS) |
|||
Communication |
RS485 communication(Modbus protocol) |
|||
Work Environment |
Temp:0~50℃ relative humidity:≤85%RH (none condensation) |
|||
Storage Environment |
Temp:-20~60℃;relative humidity:≤85%RH(none condensation) |
|||
Power supply |
DC24V±4 V |
|||
Protection level |
IP65(with back cover) |
|||
Dimensions |
130mm×180mm×60mm(H×W×D) |
|||
Hole size |
122mm×172mm(H×W) |
|||
Installation |
Panel mounted,fast installation |
2. Product Show
♦ Part two: Frotec Conductivity Controller Packaging
♦ Part three: Frotec Serivce
1. Our Service
Welcome to your inquiry,you are promised to get our quotation withing 24 hours
We are pleased to send you a sample on you confirm
We promise that we will implement your order on time
You are promised to get the best quality at the best price with the best service
2.FAQ
a.OEM service available for filter cartridge?
Yes, OEM service is available, but the Frotec brand price better than OEM
b.Payment Term
We can accept L/C, T/T, Western Union, MoneyGram and paypal
c.Certicification
We had passed ISO9001
d.Shipping
If your order is not big enough , Door to Door Service is the best choice via UPS,FEDEX,DHL,EMS.
For big quantity, by air or by sea through your forwarder is one Normal Way , we also can provide cost-effective forwarder for your reference.
e. Lead time
The normal lead time is 7-15 days, which depends on your quantity.