PRODUCT | PROBLEM | PROBABLE REASONS | CORRECTIVE ACTIONS | ||
One Piece Water Closet | Water not coming in Bowl area while flushing. | Mechanism inside tank may not be working properly. | Change the center pump of mechanism. | ||
Water is continuously leaking Inside the Bowl. | There is no water in tank. | Increase the ball cock height to the maximum level. | |||
Water Quantity insufficient for effective Flushing. | Mechanism inside tank may not be working properly. | Change the center pump of mechanism. | |||
Uneven flow of water from both side of Closet. | Ball Cock height adjusted at lower level. | Increase the ball cock height to the maximum level. | |||
Overflow chocked and foul bad odour. | Waste coupling used may be full threaded. | Waste coupling should be replaced by slot cut coupling. | |||
Water deposit on tap platform area and inside. | Basin is not flued in level or bracket is not in level. | Should be done by proper leveling. | |||
There is no tap hole in Basin. | Tap hole can be semi punched from back side. | Tap Hole should be created by plumber from semi punched area. | |||
Insert the flush pipe up to the end of inlet for Pan / Closet check whether flush pipe is not covering flush hole which is in both side of inlet. | |||||
Closet / Pan may not be Levelled. | Should be done by proper levelling. | ||||
AFTER SALES SERVICE : | AFTER RECEIVING THE PRODUCTS, IF YOU FOUND ANY QUALITY PROBLEM, PLEASE CONTACT US IN TIME BY EMAIL. WE WILL DEFINETLY FIND A MOST SUITABLE SOLUTIONS FOR IT. |
Name of Test | As Per IS 2556 (Part) 1994 | Vistaar Overseas Value | ||
Water Absorption | Average value should not exceed more than 0.5 % | Max 0.30 % show better vitrification. | ||
Crazing Test | No crazing up to 2 cycle up 5 hrs each cycle or 10 hrs at pressure 0.34 to 0.37 Mps. | No problem up to 4 cycle and no crazing. | ||
Chemical Resistance | No loss of reflectivity of the glaze when compared with control sample. | No loss of reflectivity of the glaze when compared with control sample. | ||
Modules of Repture | Not less than 60 Mpa. | Minimum 65 Mpa. / Minimum 80 Mpa. | ||
Resistance to Staining and Burning | No stain shall remain on either of test piece. | No stain shall remain on either of test piece. | ||
Discoloration | None on all visible surface. | None on all visible surface. | ||
Wavy Finish | None on all visible surface. | None on all visible surface. | ||
Note : All products dimension may vary 10 % to 15 % from the dimension given in the catalogue. |