Goodrive10 mini economical inverter is positioned as a common application in the low-power OEM supporting market. It adopts vectorized V/f control technology and has multiple common functions such as PID, multi-speed, DC braking, and Modbus communication. It has complete functions and volume. Smaller, can further reduce the installation space.
Features
Vectorized V/f control;
Natural heat dissipation, applicable to occasions with a lot of cotton wool and dust;
Mini design, save customer installation space;
Standard configuration with potentiometer and external LED keyboard;
Product design strictly follows IEC international standards and meets CE certification testing requirements;
Set a variety of commonly used functions to meet application requirements:
(1) Standard Modbus communication;
(2) Built-in PID;
(3) With 16 speed control;
(4) Multi-point V/F curve setting can be carried out;
(5) With multi-function input and output ports, and the switch value can be set to delay time;
(6) It has protection functions such as overcurrent, overvoltage, undervoltage, overtemperature, and overload, and can save fault information;
(7) With DC braking, magnetic flux braking, and resistance energy consumption braking;
(8) Over stall speed, over voltage stall, stronger load adaptability.
Specifications
Function description Specification
Rated input voltage (V) Single phase 220V(-15%)~240V(+10%)
Three-phase 200V(-15%)~240V(+10%)
Three-phase 380V(-15%)~440V(+10%)
Rated input frequency (Hz) 50Hz or 60Hz, allowable range 47~63Hz
The rated output voltage (V) is equal to the input voltage, and the error is less than 5%
Rated output frequency (Hz) 50Hz/60Hz, fluctuation range: ±5%
Control method V/f control
Maximum output frequency 400Hz
Speed ratio 1:100
Overload capacity 150% rated current for 1 minute, 180% rated current for 10 seconds, 200% rated current for 1 second
Analog input resolution is not more than 20mV
Terminal switch input resolution is not more than 2ms
Analog input and output Input 1 way 0~10V or 0~20mA, output 1 way 0~10V or 0~20mA
Digital input and output 5 ordinary inputs, 1 Y terminal output (shared with ordinary digital output), 1 programmable relay output
Communication 485 communication
Installation method Wall-mounted installation
Operating environment temperature -10~50℃, derating use above 40℃
Cooling method Single/three-phase 230V 0.2~0.75KW natural cooling;
Single/three-phase 220V 1.5~2.2KW, three-phase 380V 0.75~2.2KW forced air cooling
Fault protection function Provides dozens of fault protection functions: over current, over voltage, under voltage, over temperature, overload and other protection functions
Braking unit built-in as standard
Model | Output power (kW) | Input current (A) | Output current (A) | |
Single phase 220V | GD10-0R2G-S2-B | 0.2 | 4.9 | 1.6 |
GD10-0R4G-S2-B | 0.4 | 6.5 | 2.5 | |
GD10-0R7G-S2-B | 0.75 | 9.3 | 4.2 | |
GD10-1R5G-S2-B | 1.5 | 15.7 | 7.5 | |
GD10-2R2G-S2-B | 2.2 | 24 | 10 | |
Three-phase 220V | GD10-0R2G-2-B | 0.2 | 1.9 | 1.6 |
GD10-0R4G-2-B | 0.4 | 2.7 | 2.5 | |
GD10-0R7G-2-B | 0.75 | 4.9 | 4.2 | |
GD10-1R5G-2-B | 1.5 | 9.0 | 7.5 | |
GD10-2R2G-2-B | 2.2 | 15 | 10 | |
Three-phase 380V | GD10-0R7G-4-B | 0.75 | 3.2 | 2.5 |
GD10-1R5G-4-B | 1.5 | 4.3 | 4.2 | |
GD10-2R2G-4-B | 2.2 | 7.1 | 5.5 |