Model | BND-IPX14B-R200 | BND-IPX14B-R400 | ||
Inner dimension | 500L*500D*650H mm | 900L*900D*1050H mm | ||
Outer dimension | 1000*680D*1400H mm | 1350L*1150D*1750H mm | ||
Turntable diameter | ¢200mm | ¢400mm(R200mm is optional) | ||
Turntable Max. load | 50KG | 50KG | ||
Turntable lifting height | 150-250 mm | 450-750 mm | ||
Turntable tiltable angle | 0° or 15°(horizontal direction) | 0° or 15°(horizontal direction) | ||
Turntable speed | 1 -5r/min(precise control ) | 1 -5r/min(precise control ) | ||
Turntable rotate | Foreward / Turn back and forth / intermittent rotation | Foreward / Turn back and forth / intermittent rotation | ||
Testing time | 0-999 min | 0-999 min | ||
Total weight | Appro. 230kg | Appro. 230kg | ||
IPX12 technology parameter | ||||
Drip plate area | 200*200mm | 600*600mm | ||
IPX12 Spray aperture diameter (mm) | ¢0.4mm | ¢0.4mm | ||
Space of Dripping aperture | 20*20 mm | 20*20 mm | ||
Rainfall precipitation | IPX1=1mm/min IPX2=3mm/min | IPX1=1mm/min IPX2=3mm/min | ||
Flow adjust | Manual setting | Manual setting | ||
Drip plate lifting | Fixed | Fixed | ||
IPX34 technology parameter | ||||
Swing pipe radius | R200mm | R400mm(R200mm is optional | ||
Swing pipe Flow | IPX3=0.56L/min;IPX4=0.84L/min | IPX3=1.1L/min;IPX4=1.8L/min | ||
Spray aperture size(mm) | 0.4mm | 0.4mm | ||
Space of Spray aperture | 50mm | 50mm | ||
Swing pipe inner diameter(mm) | 15mm | 15mm | ||
Swing pipe angle | 120º(IPX3)、350º(IPX4)(precise control or customize) | 240°Turn back and forth 4S、720°Turn back and forth 12S(precise control or custom | ||
Swing pipe speed | 240º(4s) 720º(12s), or customize | R400mm(R200mm is optional | ||
Electric parameter | ||||
Power Supply | 220V | |||
Power Supply of samples | 220V | |||
Power | 1.0KW | |||
Protective device | Leakage, water shortage, short circuit | |||
Standards | IEC60529:1989 +A1:1999 +A2:2013《Degrees of protection provided by enclosures(IP Code)》 |