Exclusive Feature |
1. Low frequency, pure sine wave output.
2. Wide AC voltage input range, AVR output.
3. Built-in isolation transformer.
4. Built-in PWM/MPPT solar controller.
5. LCD & LED display, concise and straight forward.
6. AC prior/Solar prior selectable.
7. 50Hz/60Hz automatic recognition.
8. RS232 communication port optional.
9. Support diesel/gasoline generator input.
Product Details |
Technical parameter |
Specification | |||
Model NB-P | 70296-100 | 702192-100 | |
Rated Power | 7000W | 7000W | |
Battery Voltage | 96VDC | 192VDC | |
N.W.(kg) | 68 | 72 | |
G.W.(kg) | 78 | 82 | |
Size(L*W*Hmm) | 485*300*646 | ||
Packing Size(L*W*Hmm) | 550*365*785 | ||
Parameter | |||
Input | Battery Input Voltage Range | 84V~120V for 96V system; 168V~240V for 192V system | |
AC Input Voltage Range | 85VAC~138VAC/170VAC~275VAC | ||
AC Input Frequency Range | 45Hz~65Hz(50Hz/60Hz automatic recognition) | ||
Output | Efficiency(Battery Mode) | ≥85% | |
Output Voltage(Battery Mode) | 110VAC±2%/220VAC±2% | ||
Output Frequency(Battery Mode) | 50Hz±0.5/60Hz±0.5 | ||
Output Wave(Battery Mode) | Pure Sine Wave | ||
Efficiency(AC Mode) | >99% | ||
Output Voltage(AC Mode) | 110VAC±10%/220VAC±10% | ||
Output Frequency(AC Mode) | Tracking Automatically | ||
Output waveform distortion(Battery Mode) | ≤3%(Linear load) | ||
AC charger | AC charging current | Max 15A | |
AC charging voltage | Charge Voltage: 112V for 96V system, 224V for 192V system; Float Voltage: 110.4V for 96V system, 220.8V for 192V system | ||
AC charging method | Three-stage(constant current, constant voltage, floating charge) | ||
Solar charger | Charging Mode | PWM | PWM |
Max charging current | 100A | 100A | |
PV Input Voltage Range | 120V-176V | 240V-352V | |
Max PV Input Voltage(At 25℃) | 200V | 400V | |
Max PV Array Power | 11.2KW | 22.4KW | |
Maximum conversion efficiency | >95% | ||
Battery Type | Customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements | |
Working Mode(Selectable) | AC prior(→AC through Switch DC-AC) | Under AC prior mode, device will always use utility source and through regulator to supply loads as well as charge battery(charging current selectable); when utility power is with high/low/serious distortion or other abnormal, device will auto trasfer battery source to supply loads. | |
Solar prior(→DC through Switch DC-AC) | Under Solar prior mode, device will always use solar source to supply load and rest to charge battery; when solar source is insufficient, device will auto converter battery source supply loads together; when battery source is failed, device will auto use utility source and through regulator to supply loads. | ||
Protection | Battery low voltage alarm | 88V for 96V system; 176V for 192V system | |
Battery low voltage protection | 84V for 96V system; 168V for 192V system | ||
Battery high voltage alarm | 120V for 96V system; 240V for 192V system | ||
Battery high voltage protection | 136V for 96V system; 272V for 192V system | ||
Battery high voltage recover | 116V for 96V system; 232V for 192V system | ||
Overload protection | Automatic protection(battery mode), circuit breaker or fuse (AC mode) | ||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or fuse (AC mode) | ||
Temperature protection | >90°C(Shut down output) | ||
Alarm | A | Normal working condition, buzzer has no alarm sound | |
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload | ||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||
Transfer Time | ≤4ms | ||
Display | LCD & LED | ||
Thermal method | Cooling fan in intelligent control | ||
Communication | RS232(Optional) | ||
Environment | Operating temperature | -10℃~40℃ | |
Storage temperature | -15℃~60℃ | ||
Noise | ≤55dB | ||
Elevation | 2000m(More than derating) | ||
Humidity | 0%~95% ,No condensation | ||
Note: All specifications are subject to charge without prior notice |
How to Use the Solar Inverter? |
1. Battery number and capacity should be configured according to the rated voltage of the solar power system or inverter;
2. We offer 3 optional working modes:
01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
Practical Application |
Packaging & Shipping |
Package
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.
Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.
Payment Term |
T/T | EXW | 30% T/T in advance, balance paid before dispatch |
FOB | ||
CNF(CFR) | 30% T/T in advance, balance paid against copy of B/L | |
CIF | ||
L/C, D/A, D/P, Money Gram, Western Union, Paypal (Optional) |
Why Choose Xindun Power? |
About us |
Guangdong Xindun Power Technology Co.,Ltd | |
Factory Location |
Foshan,Guangdong,China |
Industry Experience |
13-year manufacturer, 16-year trading, 8-year alibaba gold supplier |
Product Range |
solar inverter, hybrid inverter, ups, solar charge controller, solar power system, mini solar dc system |
Main Market | Africa, Middle East, Asia & South America. (Ukraine, Russia, Vietnam, Pakistan, Nigeria, Kenya, South Afriac, Ghana, Thailand, Philippines, etc.) |
Factory | 6000 Square Meters, 60+ workers |
Department | R&D, Production, Sales, Marketing, Purchasing, QA, After-sale service department |
Certificate | ISO9001:2015, CE, IEC, etc. |
Patent | Software Paten, Design Patent, Project Pantent |
Workshop |
Production Process |
EXHIBITION & CUSTOMER |
CREDIBILITY |
FAQ |
A: Are your inverters pure sine wave output?
Q: A Yes, All are true pure sine wave.
A: What kind of output you can do?
Q: Normally we produce inverter with 110V 115V 120V 220V 230V 240V, 50/60Hz self-adaption. If you have special requirements, please tell us for engineer consulting.
A: What' s the difference between low frequency and high frequency inverter?
Q: Low frequency inverter has various protections, strong ability to adapt to the environment. more reliable, with voltage regulation.
A: What's the difference between pure sine wave inverter and modified sine wave inverter?
Q: Pure sine wave output inverter is just as good as the Public power grid. Even better. Low repaired rate, long lifespan, Without harmonic pollution, enviromental-friendly and appliances protected.
Modified sine wave output has a negative impact on appliances and can't load inductive load, such as air contition, refrigerator and etc. Certain motor control circuits don't like the modified wave.
A: What appliances your inverters can load?
Q: Our inverter can be used in household, Office, agricultural appliances and other inductive load such as refrigerator, air conditioner, water pump, etc.
A: Can you print our company logo on inverters, nameplates and packaging?
Q: Yes, we accept OEM orders.
A: How to choose a right inverter?
Q: Tell us your demand, then our sales will recommend a suitable inverter to you.
A: How to solve the technical problem?
Q: 24 hours after-service consultancy just for you and to make your problem to solveeasily.
A: Do I Need A Power Inverter?
Q: Actually, no. This is the only component of a solar energy system that is not absolutely required. However, if you don't use one, you will not have 220 or 230 volts AC and will have use battery power alone. This might be acceptable in a small RV or cabin, but most people want to use normal AC appliances.
A: What's The Difference Between 12, 24, And 48 Volt Inverters?
Q: This refers to the input voltage from the battery bank. The main consideration is that at higher voltages the current is less so that you can use smaller wires between your solar panel array and your battery bank. Of course, when you decide on a system voltage, the Solar Panels, Inverter, and Battery Bank all need to use the same voltage.
A: What to do if the product is broken?
Q: If any product is faulty, you can send the picture or video to us, we sill study it and supply the spare parts of PCB board free for after sale service.