Body weight measurement | Measuring system | Resistance strain gauge | ||
Body weight index | Automatic intelligent calculation of body mass index | |||
Range of measurement | 500kg | |||
Height measurement | Verified precision | ±0.1kg | ||
Measuring system | Ultrosonic probe | |||
Range of measurement | 90.0~200cm | |||
Verified precision | 0.1cm | |||
Blood pressure measurement | Display | LCD Digital Display | ||
Measurement Method | Oscillometric method | |||
Measurement Range | Pressure: 0 mmHg to 299 mmHg, Pulse: 40 to 180/min. | |||
Accuracy | Pressure: ±3 mmHg, Pulse: ± 5% | |||
Inflation | Electric pump | |||
Deflation | Automatic pressure release valve | |||
Pressure Detection | Capacitive pressure sensor | |||
Memory | 84 Measurements with date and time for each user | |||
(A and B) | (A and B) | |||
Power Source | AC/DC adapter (Included; Input 100-240V 50Hz/60Hz, | |||
AC/DC adapter (Included; Input 100-240V | Output 6V/9.6W) | |||
50Hz/60Hz,Output 6V/9.6W) | 10°C to 40°C/30 to 85% RH | |||
Storage temperature/Humidity/Air Pressure | -20°C to 60°C/10 to 95% RH700 - 1060 hPa | |||
Console Weight | Approximately 2600 g | |||
Outer Dimensions | Approximately 286 (l) mm * 294 (w) mm * 271 (h) mm | |||
Arm Circumference | 22 to 42 cm | |||
Measurement of fat | Measuring system | Multi-frequency 4- Electrode | ||
Measurement frequency | 5kHz/50kHz/250kHz/500kHz | |||
Measurement category | Body fat, Muscle, Visceral fat, Body water, Basal metabolism, Body Type | |||
Material | Electroplating material | |||
Current for measurement | 90μA or below | |||
Range of measurement | 75.0~1,500.00Ω(0.1ΩUnit) | |||
Body parts of surveyor | Body, right leg, left leg, right arm, left arm | |||
Measurement of blood oxygen | Blood oxygen probe | CREATIVE KS-CM01 | ||
Sensor | Dual wavelength LED | |||
Wavelength | "Visible light( Max):663nm | |||
Invisible Light:890nm" | ||||
Measurement range | 35%~100% | |||
Average output power(Max) | ≤2mW | |||
Measurement error | In the range of 70% to 100% < ±2% | |||
Accuracy | In the range of 70% to 100% < ±3% | |||
Pulse rate measurement error | 30~250bpm | |||
Monitoring error is ±2bpm or ±%2, whichever is the largest | ||||
Working humidity | 5℃~40℃ | |||
Relative humidity | 15%~95%(Non-condensing) | |||
Atmospheric pressure | 70kpa~106kpa | |||
Power supply mode | Powered by ancillary equipment | |||
Range of measurement | 95-99%(±2%normal status,±3% motion or weak perfusion,less than 95% undefined) | |||
Body temperature | Infrared thermometer | Calibeur DT-8836 | ||
Accuracy | 0.1 ℃ | |||
Operating Temperature | 10~40℃ | |||
Storage temperature | 0~50℃ | |||
Relative humidity | ≤85% | |||
Power supply | DC 9V(6F22:a layer-built battery) | |||
Specification | 150*75*40mm | |||
Weight | Gross weight:400g, Net weight:172g | |||
Body temperature range | 32.0~42.5℃ | |||
Object temperature range | 0~100℃ | |||
Accuracy | ≤±0.3℃ | |||
Power dissipation | ≤120mw | |||
Measurement distance | 5-8cm | |||
Auto power off | About 15 seconds |