Hospital Grade Isolation Transformers for Ground Fault Location in Ungrounded System
  • Hospital Grade Isolation Transformers for Ground Fault Location in Ungrounded System

Hospital Grade Isolation Transformers for Ground Fault Location in Ungrounded System

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meo wig Trading Co., Ltd
Meo wig Trading Co., Ltd
China - Hangzhou
Manufacturer
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
51-100 people
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
BRC
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Jiangsu, China
Brand Name:
Acrel
Model Number:
AITR10000, AITR8000, AITR6300, AITR5000, AITR3150
Usage:
Power
Phase:
Single
Coil Structure:
Coil
Coil Number:
customized
Rated Capacity:
3.15kVA/5kVA/6.3kVA/8kVA/10kVA
Frequency:
50/60Hz
Rated input voltage:
230V
The output voltage:
230V/115V
Inrush current:
V <12In
Leakage Current:
<200uA
No-load output voltage:
<235V
No-load output current:
<3% In
Short-circuit voltage:
<3% Un
Insulation Class:
H
Supply Ability
Supply Ability:
1000 Piece/Pieces per Month
Packaging & Delivery

ACREL AITR series Hospital Grade Isolation Transformers for Ground Fault Location in Ungrounded System


ACREL hospital-grade Isolation Transformers provide isolation between primary and secondary voltages, and intended for using as a part of an isolated power system in the Hospital.
Features
● Capacity: 3.15, 5, 6.3, 8, 10 KVA
● Noise Level: <40dB
● Insulation Class: H
● Short Circuit Voltage ≤ 3%
● No-load Output Current ≤ 3%
● Inrush Current ≤ 12 In
● Leakage Current <0.2mA
● Efficiency >96%
Standard
◆ IEC 61558-1:2009 Safety of transformers, reactors, power supply units and combinations thereof—Part 1: General requirements and tests ◆ IEC 61558-2-15:2011 Safety of transformers, reactors, power supply units and combinations thereof—Part 16: Particular requirements and tests for isolating transformers for the supply of medical locations ◆ IEC60364-7-710:2016 Electrical installations of buildings—Part 7-710:Requirements for special installations or locations—Medical locations
Technical Parameters
Rated Capacity
3.15kVA/5kVA/6.3kVA/8kVA/10kVA
Frequency
50/60Hz
Rated input voltage
230V
The output voltage
230V/115V
Inrush current
<12In
Leakage Current
<200uA
No-load output voltage
<235V
No-load output current
<3% In
Short-circuit voltage
<3% Un
Efficiency
>96%
Maximum ambient temperature
<40℃
No-load temperature rise
<33℃
Full load temperature rise
<76℃
Withstand voltage
4200V/Min
Insulation Class
H
Noise Level
<40dB (A)
Dimensions and Model Selection
Hospital Grade Isolation Transformers for Ground Fault Location in Ungrounded System from China supplier
Model
Capacity(VA)
Dimensions(mm)
Weight(Kg)
A
B
C
D
E
F
AITR10000
10000
280
275
427
240
190
φ11
92
AITR8000
8000
280
265
427
240
190
φ11
90
AITR6300
6300
280
255
427
240
175
φ11
75
AITR5000
5000
280
255
427
240
175
φ11
73
AITR3150
3150
280
225
427
240
175
φ11
53
Name Rule
Hospital Grade Isolation Transformers for Ground Fault Location in Ungrounded System from China supplier
Comparison
Type
AITR10000
AITR8000
AITR6300
AITR5000
AITR3150
Rated power
10000VA
8000VA
6300VA
5000VA
3150VA
Insulation class
H
H
H
H
H
Protection class
IP00
Rated frequency
50-60Hz
Rated input voltage
AC230V
Rated input current
45.3A
36A
28.5A
22.5A
14.2A
Rated output voltage
AC230V/115V
Rated output current
43.5A
34.7A
27.4A
21.7A
13.7A
Inrush current
<12In
Leakage current
<200μA
No load input current
1.359A
1.08A
0.855A
0.675A
0.426A
No load output voltage
235V±3%
Short circuit voltage
<6.9V
<7.5V
General parameters
Type
AITR10000
AITR8000
AITR6300
AITR5000
AITR3150
Fuse wire
80A
63A
50A
35A
25A
Primary winding resistance
<55mΩ
<64mΩ
<80mΩ
<131 mΩ
<245mΩ
Secondary winding resistance
<45mΩ
<64mΩ
<80mΩ
<116 mΩ
<228mΩ
Iron loss
<150W
<105W
<107W
<77W
<55W
Copper loss
<230W
<200W
<170W
<125W
<120W
Efficiency
>96%
>95%
Maximum ambient temperature
<40℃
No-load temperature rise
<36℃
<33℃
<31℃
<26℃
<22℃
Full load temperature rise
<65℃
<76℃
<67℃
<62℃
<55℃
Noise grade
<40dB
Selection Description
Any isolation transformer will generate inrush current at start time ,Therefore, for the medical IT systems , In selecting the circuit breaker which is installed in the line circuit into an isolation transformer , Breaker has short-circuit protection and without overload protection, such as ordinary breaker should be selected in line of C, D circuit breaker tripping curves, And the rated current should be determined according to the following relationship with isolation transformer capacity: 10kVA-63A, 8kVA-50A,
6.3/5kVA-40A, 3.15kVA-20A, to prevent the impact of the current circuit breaker switching difficulties or safety-power tripping, resulting in serious medical malpractice .
Wiring Diagram and Terminals
Hospital Grade Isolation Transformers for Ground Fault Location in Ungrounded System from China supplier
The isolation transformer is installed in the bottom of the distribution cabinet fixed with matching bolts, and the cooling fan should be installed. If the isolation transformer is installed separately, it is not suitable to put it too far away from the AIM-M200 insulation monitor.
The input terminals at the transformer terminal blocks are labeled with “PM”, in which two terminals 0 and 230 are connected to the input 220V single-phase AC. The output terminals are labeled with “SEC”, in which the output voltage of two terminals 0 and 230 is AC 220V and is connected to external field load. The S terminal is connected to the PE bus bar on the spot (or the equipotential terminal line). Two ST terminals are temperature sensor interfaces, which are respectively connected to the No.13 and 14 terminals of AIM-M200 insulation monitoring instrument. 
Note:
1) The S terminal wiring can select 2×4mm2 yellow-green wire. The wiring of two ST terminals can select 2×1.5mm2 shielded twisted pairs, and the wiring should not be too long. 2) The connection line diameter of the input and output of the isolation transformer should match the rated current of the isolation transformer, or it can be selected according to the following table:
Isolation transformer type
Selected line diameter
AITR3150
3×4mm2
AITR5000/AITR6300
3×6mm2
AITR8000/AITR10000
3×10mm2
3) Special reminder: Any isolation transformer will have an impact current when it starts up, and too large impact current may cause the circuit breaker at primary side of the transformer difficult to disconnect or shut down. Therefore, for medical IT systems composed of medical isolation transformers and insulation monitoring products, in the selection of inlet circuit breaker of the isolation transformer, it is recommended to choose the circuit breakers only with short circuit protection but without overload protection according to GB requirements. If choosing the circuit breaker with overload protection, the circuit breaker should conform to the C and D tripping curves of GB14048.2-2008, and the rated current of the circuit breaker should be determined according to the capacity of the isolation transformer as follows: 10kVA-63A, 8kVA-50A, 6.3kVA-40A, 5kVA-40A, 3.15kVA-20A. If the circuit breaker selection is not in accordance with the above requirements, the company shall not be liable for any medical malpractice caused by the closure difficulty of the circuit breaker or the disconnection of the circuit breaker during operation.
No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToEmily Li
Meo wig Trading Co., Ltd
Enquire
Related Categories
BatteriesCircuitBreakersContactorsFuseComponentsFusesRelays
Popular Searches
tea bottling equipmentmodern dental lab equipmenttai chi equipmentholistic equipmentspeed skating equipmenthdpe electrical conduittyre service equipmentbin cleaning equipmentelectrical tajinegeotechnical equipmentused anesthesia equipment0 electrical wireschiller medical equipmentkernel medical equipmentelectrical turtlelowes electrical outletsreception equipmentecu laboratorial equipmentthermodynamics lab equipmentpaint testing equipmentice cream truck equipment0.3mm electrical wire0.3mm electrical wireink testing equipmentland leveling equipmentfan testing equipmentbeef jerky equipmentwater leak testing equipmentsteel plate handling equipmenttextile lab equipmentrubber vulcanizing equipmentround electrical ovencar electrical switchestj electrical socketmold lifting equipmentspark testing equipmentsolar lab equipmenthair salon electrical equipmentoven cleaning equipmentused rescue equipment