Operational use
How to( limit current) to adjust current? This step just for adjust the current, if you no need adjus the crrent, you can do not
do it.
1. Turn off the power, the switching power supply without load. insert the plug (special for adjust current) to the 6th and 7th
ports of the wiring port, loosen the port screw with a screwdriver, and tighten with a screwdriver (at this time, connect to the
listed power). as above the pciture.
2.Turn on the power, adjust right side knob, (adjust current knob), you can adjust the desired current limit parameter, and
display the current parameter synchronously with the digital display. 0-40A/0-20/0-17A/0-28 can be adjusted in the whole process.
3. Turn off the power, Remove the (special adjustment current plug), and then connect with your load.
When the load device is connected, the current value can be adjusted directly in real time. The maximum current value is the
maximum current value of the load device. If the current adjustment knob clockwise exceeds the maximum current value of the
device, the digital current value will not last. Real-time synchronized digital display, showing only the maximum current value of
the device.
Uses: Mainly used for various battery charging, DC equipment, DC motor stepless speed regulation, LED stepless dimming, chemical
electroplating speed regulation, scientific research test, student experiment, etc., and a wide range of uses.
Special attention: If using inductive load such as motor or fan, please pay attention to the maximum starting current parameter of
the motor. This parameter must not be higher than the maximum operating current of the power supply. Otherwise, the power supply
may be damaged. You should select a higher current power supply or soften the motor. The protection circuit is activated to absorb
the inrush current.
Power formula) voltage X current = power
Terminal description and wiring method
L, N AC input terminal FG ground mark V+ DC output positive terminal
V-DC output negative terminal ADJ adjustable potentiometer Fine-tuning output DC voltage
● full voltage input
● Miniaturization
●Protection function Short circuit / overload / over voltage
●100% full load aging test
Input Voltage & Frequency Range----------220VAC/47~63Hz
Start surge current ---------------20A@120VAC (cold start)
Output adjustment range --------------- ±100% (rated output voltage)
Overload protection -------------------105%~200% (rated load), self-recovery
Overvoltage protection -------------------115%~135% (rated output voltage)
Short circuit protection ------------------- self-recovery
Output start time ---------------≤2S@120VAC ≤1.0S@230VAC
Output hold time ---------------≥10mS@120VAC, ≥20mS@230VAC
Insulation strength ------------------- Input - Output: AC1500V, 1min
Input - housing: AC1500V, 1min
Output - Case: DC500V, 1min
Working environment ------------------ -10 ° C ~ 50 ° C; 20% ~ 90% RH (no condensation)