X-ray generator | ||
High frequency inverter frequency | 40kHz | |
Output power | 5KW(100kV、50mA、0.1s) | |
Fluoroscopy tube voltage | 40-120KV | |
Radiography tube voltage | 40-120KV | |
Rotating anode, dual focus, small 0.3mm, large 0.6mm | ||
Collimator | ||
X-ray filed size | 0~35cm×35cm@100cm SID continuous adjustable | |
electric lung field iris copper sheet, iris collimator can rotate counterclockwise/clockwise, can be opened and closed | Advanced WAD cooling technology | |
Advanced technology | Liquid metal bearing technology | |
Dynamic flat panel detector | ||
Type | Amorphous silicon CsI | |
Nominal area | 210mm×210mm | |
Pixel pitch | 205μm | |
Matrix | 1024×1024 | |
C-arm gantry | ||
Lateral movemen | 250mm | |
Vertical lifting movemen | 450mm | |
Swing left & right | 25°(±12°,error ±1°) | |
C-arm orbital range | 135°(-45°~90°) | |
CRA/CAU | 90°/45° | |
Rotate around the horizontal axis | ±225° | |
LAO/RAO | -225°/225°, error ±1° | |
C-arm depth | 780mm | |
C-arm opening | 820mm | |
SID | 1050mm | |
Control device | ||
Hand switch | Two steps hand switch | |
Foot switch | Dual pedal | |
Console box | 4 joysticks and 5 buttons | |
Imaging acquisition & processing system | ||
Workstation | 1*PC, CPU2.8GHz, 8GB memory, 1T hard disk,120GSSD, 2 *USB2.0 interface | |
Vertical movement range | 2* 19’ touch-screen medical monitors on trolley; 1* 13.3’ touch-screen monitor on C-arm gantry | |
Lateral movement range | Monitor: DICOM calibration function, meets DICOM standard | |
Fluoroscopy | ||
3 FLU modes: normal FLU, low-dose FLU and high-dose FLU | ||
Supporting continuous fluoroscopy and pulse fluoroscopy | ||
Last image hold function after fluoroscopy | ||
Radiography | ||
CINE mode supports 6 different frame: 1,2, 4, 8, 16, 30fps | ||
Spot film supports 0.4-320mAs,R’10 | ||
Loading time in spot film mode: 40-4000ms, R’10 | ||
Imaging post-processing | ||
Window width/level adjustment | ||
Recursive noise reduction | ||
Imaging zoom | ||
Magnifier | ||
Imaging rotation | ||
Horizontal image | ||
Vertical image | ||
Annotation, including polygon, circle, rectangle, line, arrow and text. | ||
Line segment and angle measurement function | ||
Image data management | ||
New cases, worklist search, add new examination to exist patients. | ||
Deleting cases, delete one or more examinations of patient | ||
Researching cases according to registration date, patient name & ID, including patients who have completed the examination or who have not completed the examination | ||
Support DICOM 3.0 standard worklist inquiry service, download cases information from HIS/PACS | ||
Image browsing | ||
Real-time image browsing supports frame rate adjustment of playback. | ||
Real-time image browsing supports current sequence loop play. | ||
Real-time browsing supports thumbnails to browse all sequences of current cases | ||
Print & storage | ||
DICOM film printing is supported | the processed DICOM images can be transferred to a DICOM printer for printing into film. | |
Print device managemen | Multiple printers can be supported at the same time and are compatible with a variety of DICOM format printers | |
Print format | Supports a variety of film sizes, with a variety of vertical and horizontal layout functions | |
Support the images export of selected cases to USB flash drives and CD/DVD discs | ||
Support the images export of selected cases to USB flash drives and CD/DVD discs | ||
Output comes with DICOM image browser |