Features of Holtop rotary heat exchanger
- Synthetical material with high hydrophilicity. 3A molecular sieve can effectively avoid secondary pollution.
- Advanced technology and special rotary heat exchanger design, high efficiency up to 90%, sensible heat and enthalpy recovery available.
- Double sealing system and purge sector, air leakage less than 0.3% when temperature different is above 200Pa
- Various installation type and motor position available, convenient for each project case.
- Built in top quality imported motor from Germany, CE and ce certificated.
90% efficiency of Holtop rotary heat exchanger
Rotary heat exchanger, also known as heat recovery wheel, thermal wheel and enthalpy wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, in order to recover the heat energy.
Specifications and dimensions of Holtop rotary heat exchanger
Working principle of Holtop rotary heat exchanger
Rotary heat exchanger is composed of alveolate heat wheel, case, drive system and sealing parts. The exhaust and outdoor air pass through half of the wheel separately, when the wheel rotates, the heat and moisture are exchanged between the exhaust and outdoor air. The energy recovery efficiency is up to 70% to 90%.
Product details of Holtop rotary heat exchanger
Wheel materials
The sensible heat recovery wheel is made by aluminum foils of 0.05mm thickness. And the enthalpy recovery wheel is made by aluminum foils coated with 3A molecular sieve of 0.04mm.
Casing construction
Wheel Construction
The wheel of the rotary heat exchanger is made of alternating layers of flat and corrugated aluminum foil to form the alveolate
shape. Various height of corrugation is available. Flat surface ensures minimum leakage. Interior spokes are used to mechanically bond the rotor’s laminations. These are threaded at the hub and welded at the periphery.
Bearing and drive system
The hub of the wheel is equipped with life-time- lubricated ball bearing or roller bearing, and with covers at both sides. No maintenance is required under normal usage.
- V-belt with big interface. Long service life.
- Spring shock absorber insures steady operation.
- Integrated motor and speed reducer free from maintenance.
Installation types and motor position
The motor is installed at the corner of the rotary heat exchanger, the position of the corner is marked from no. 1 to 4, and the motor position is optional.
SPECIFICATIONS AND DIMENSIONS
Casing Type A |
|||||||||
Specifcations | A mm |
B mm |
B1 mm |
B2(A1) mm |
F mm |
D mm |
Power Kw |
Voltage | N.W. Kg |
400 | 504 | 554 | 277 | 68 | 32 | 400 | 0.09 | 3~380V50Hz | 32 |
500 | 600 | 600 | 312 | 68 | 32 | 530 | 0.09 | 3~380V50Hz | 42 |
600 | 700 | 700 | 350 | 68 | 32 | 630 | 0.09 | 3~380V50Hz | 59 |
700 | 800 | 800 | 400 | 68 | 32 | 730 | 0.09 | 3~380V50Hz | 71 |
800 | 900 | 900 | 450 | 68 | 32 | 830 | 0.09 | 3~380V50Hz | 82 |
900 | 1030 | 1030 | 515 | 98 | 32 | 930 | 0.09 | 3~380V50Hz | 102 |
1000 | 1130 | 1130 | 565 | 98 | 32 | 1030 | 0.09 | 3~380V50Hz | 130 |
Casing Type B and Type C |
|||||||||
Specifcations | A mm |
B mm |
B1 mm |
F mm |
D mm |
Power Kw |
Voltage | Up-down type/Right-left type N. W. Kg | |
1100 | 1230 | 1230 | 615 | 32 | 1130 | 0.09 | 3~380V50Hz | 151 | |
1200 | 1330 | 1330 | 695 | 32 | 1230 | 0.18 | 3~380V50Hz | 169 | |
1300 | 1430 | 1430 | 745 | 32 | 1330 | 0.18 | 3~380V50Hz | 190 | |
1400 | 1530 | 1530 | 765 | 32 | 1430 | 0.18 | 3~380V50Hz | 205 | |
1500 | 1630 | 1630 | 766 | 42 | 1530 | 0.18 | 3~380V50Hz | 212/220 | |
1600 | 1730 | 1730 | 816 | 42 | 1630 | 0.18 | 3~380V50Hz | 230/239 | |
1700 | 1830 | 1830 | 866 | 42 | 1730 | 0.25 | 3~380V50Hz | 256/266 | |
1800 | 1930 | 1930 | 916 | 47 | 1830 | 0.25 | 3~380V50Hz | 283/293 | |
1900 | 2030 | 2030 | 966 | 47 | 1930 | 0.25 | 3~380V50Hz | 301/320 | |
2000 | 2130 | 2130 | 1016 | 47 | 2030 | 0.25 | 3~380V50Hz | 358/370 | |
If the casing is with side panel, revise the dimension as per formula: A+4, B+4, B1+2, F+2. | |||||||||
Specifcations 1100-1400 are for casing B, specifcations 1500-2000 are for casing B or C. | |||||||||
Casing Type D and Type E |
|||||||||
Specifcations | A mm |
B mm |
C mm |
E mm |
F mm |
D mm |
Power Kw |
Voltage | Weight Kg |
2200 | 2400 | 2400 | 400 | 50 | 40 | 2230 | 0.37 | 3~380V50Hz | 420 |
2400 | 2600 | 2600 | 400 | 50 | 40 | 2430 | 0.37 | 3~380V50Hz | 500 |
2600 | 2800 | 2800 | 400 | 50 | 40 | 2630 | 0.37 | 3~380V50Hz | 570 |
2800 | 3000 | 3000 | 400 | 50 | 40 | 2830 | 0.37 | 3~380V50Hz | 860 |
3000 | 3200 | 3200 | 430 | 70 | 70 | 3030 | 0.55 | 3~380V50Hz | 950 |
3200 | 3400 | 3400 | 430 | 70 | 70 | 3230 | 0.55 | 3~380V50Hz | 1039 |
3400 | 3600 | 3600 | 430 | 70 | 70 | 3430 | 0.55 | 3~380V50Hz | 1110 |
3600 | 3800 | 3800 | 430 | 70 | 70 | 3630 | 0.55 | 3~380V50Hz | 1220 |
3800 | 4000 | 4000 | 430 | 70 | 70 | 3830 | 0.55 | 3~380V50Hz | 1360 |
4000 | 4200 | 4200 | 430 | 70 | 70 | 4030 | 0.75 | 3~380V50Hz | 1500 |
4200 | 4400 | 4400 | 430 | 70 | 70 | 4230 | 0.75 | 3~380V50Hz | 1645 |
4400 | 4600 | 4600 | 430 | 70 | 70 | 4430 | 0.75 | 3~380V50Hz | 1750 |
4600 | 4800 | 4800 | 430 | 70 | 70 | 4630 | 1.1 | 3~380V50Hz | 1830 |
4800 | 5000 | 5000 | 430 | 70 | 70 | 4830 | 1.1 | 3~380V50Hz | 1980 |
5000 | 5200 | 5200 | 430 | 70 | 70 | 5030 | 1.1 | 3~380V50Hz | 2100 |
If casing is with side panel, revise the dimension as per formula: A+4, B+4, B1+2, F+2 |
Holtop Factory
Holtop is the leading manufacturer in China specializing in the production of air to air heat recovery equipments. It is dedicated to the research and technology development in the field of heat recovery ventilation and energy saving air handling equipments since 2002. The main products incluses energy recovery ventilator ERV/HRV, air heat exchanger, air handling unit AHU, air purification system. Besides, Holtop also offer turnkey hvac solutions for different industry.
Holtop headquarters is located at the foot of Beijing Baiwangshan Mountain, covering area of 30,000 square meters. The manufacturing base is in Beijing's Badaling Economic Development Zone, covering an area of 60 acres, with an annual production capacity of 200,000 units of air heat recovery equipments.
Holtop builds a sound certificate system of ISO9001, ISO14001 and OHSAS18001 as well as product certification systems. Moreover, it has a laboratory certified by national authority. As a well-known manufacturer in the field of heat recovery, Holtop has a strong R&D team and possesses dozens of national invention patents, and participated in the compilation work of several national standards, Holtop was also elected as Zhongguancun High-Tech Enterprise.
Holtop partner
Holtop cooperate with so many world famous brands, offering OEM /ODM service.
Holtop certificate
Holtop products stand for TOP quality in heat recovery ventilation filed in China, certificated by CE, CB, RCM, RoHs, FCC, ISO and other different approved tests like anti-flaming test, anti-mold test, energy saving product test. Etc.