Model | Rated Voltages | Load capacity | Fuse | Weight | Useful |
VLF30KV | 30kV (peak ) | 0.1Hz,≤1.1µF | 10A | Control :6kg Body Boost :30kg | 10KV Cables,Generator |
0.05Hz,≤2.2µF | |||||
0.02Hz,≤5.5µF |
VLF50KV | 50kV (peak ) | 0.1Hz,≤1.1µF | 20A | Control :6kg Body Boost :50kg | 15.75KV Cables,Generator |
0.05Hz,≤2.2µF | |||||
0.02Hz,≤5.5µF | |||||
VLF60KV | 60kV (peak ) | 0.1Hz,≤0.5µF | 25A | Control :6kg Body Boost I:30kg Body Boost II:50kg | 18KV and below the cable,Generator |
0.05Hz,≤1.1µF | |||||
0.02Hz,≤2.5µF | |||||
VLF80KV | 80kV (peak ) | 0.1Hz,≤0.5µF | 25A | Control :6kg Body Boost I:30kg | 35KV and below the cable,Generator |
0.05Hz,≤1.1µF | |||||
0.02Hz,≤2.5µF |
Output frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Load capacity | 0.1Hz maximum 1.1µF 0.05Hz max 2.2µF 0.02Hz maximum 5.5µF |
Measurement accuracy | 3% |
Voltage positive and negative peak error | ≤3% |
Voltage waveform distortion | ≤5% |
Conditions of use | indoors and outdoors; |
Operating temperature | -10℃∽+40℃ |
Relative humidity | ≤85%RH |
Power supply | frequency 50Hz, voltage 220V±5%. |