High Reliability Lab Gas Chromatograph with TCD, FID Detectors BK-GC112A
Features:
1. 7-inch LCD display indicates temperature, gas flow and heating curve.
2. Self-test function and automatic fault recognition function.
3. 8 pcs external extension interfaces can connect with control valve.
4. Equipped with a flame ionization detector (FID) which adopts APC control.
5. Multi-core and 32-bit embedded hardware system ensures the reliable operation.
6. Synchronous external trigger function and the external signal (auto sampler, hot analytical instruments, etc.) can start the equipment and workstation software at the same time.
7. With chromatography workstation software to process data.
Model |
BK-GC112A |
||
Oven |
Temp. Range |
RT+5℃~400℃ |
|
Temp. Accuracy |
±0.02℃ |
||
Temp. Program |
9-phase/ 10 platform |
||
Max Temp. Heating Rate |
60℃/min |
||
Sample injector |
Temp. Range |
RT+7℃~420℃ |
|
Column or split injector can be installed. |
|||
Split mode can directly set the split ratio. |
|||
Constant pressure mode. |
|||
A separate injection system is connected. |
|||
Detector |
Temp. Range |
RT+7℃~420℃ |
|
Hydrogen Flame Ionization Detector (FID) |
Logarithmic amplifier |
||
High voltage switch control |
|||
Baseline signal display |
|||
Ignition coil control |
|||
Detection limit:≤3*10-12g/s (Sample: n-hexadecane) |
|||
Dynamic range: 107 |
|||
Thermal Conductivity Detector (TCD) (Optional) |
Bridge voltage switch control |
||
Bridge current setting: 0-220mA |
|||
Sensitivity: 6000mv.ml/mg |
|||
Dynamic range: 105 |
|||
Power Supply |
AC220V±10%, 50/60Hz |
||
Standard Accessory |
FID detector, Capillary injection system, Chromatography workstation software. |
||
Optional Accessory |
TCD detector, Chromatographic column, Gas purifier. |
||
Package Size (W*D*H) |
1020*660*740mm |
||
Gross Weight |
82kg |
Gas Chromatograph
Model |
BK-GC7820 |
|
Oven |
Temp. Range |
RT~450℃ |
Temp. Accuracy |
≤±0.1℃ |
|
Temp. Program |
16-phase |
|
Max. Temp. Heating Rate |
40℃/min |
|
Detector |
Hydrogen Flame Ionization Detector (FID) |
Detection limit:≤3×10-12g/s (Sample: n-hexadecane) |
Baseline drift:≤1x10-13A/30min |
||
Linear range:≥107 |
||
Thermal Conductivity Detector (TCD) (Optional) |
Sensitivity: >10000mv.ml/mg (Sample: n-hexadecane) |
|
Linear range:≥105 |
||
Electron Capture Detector (ECD) (Optional) |
Detection limit:≤1×10-14g/ml (Sample: n-hexadecaneδ-666) |
|
Linear range:≥103 |
||
Flame Photometric Detector (FPD) (Optional) |
Detection limit:≤2×10-11g/s (S of thiophene) Detection limit:≤1×10-12g/s (P of methyl parathion) |
|
Linear range (S):≥102 Linear range (P):≥103 |
||
Nitrogen and Phosphorus Detector (NPD) (Optional) |
Detection limit:≤1×10-12g/s (Azobenzene) Detection limit:≤1×10-12g/s (Marla sulphur phosphorous) |
|
Linear range:≥103 |
||
Power Supply |
AC110/220V±10%, 50/60Hz |
|
Standard Accessory |
FID detector, Chromatography workstation software |
|
Optional Accessory |
Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column. |
|
Package Size (W*D*H) |
800*570*650mm |
|
Gross Weight |
75kg |