Function |
Test condition |
Symbol |
Test condition |
Specification |
Unit |
|||||
Min |
Typ |
Max
|
||||||||
P R O T E C T I O N
F U N C T I O N
|
Over charge protection |
Over charge protection voltage |
Vc1 |
At charge off |
4.22 |
4.25 |
4.28 |
V |
||
Over charge protection delay time |
Tc1 |
/ |
0.5 |
1.0 |
3.0 |
S |
||||
Over charge protection release voltage |
Vc2 |
/ |
4.10 |
4.15 |
4.20 |
V |
||||
Charging current |
normal charging current |
Ioc |
/ |
/ |
/ |
5 |
A |
|||
Over discharge protection |
Over discharge protection voltage |
Vd1 |
At discharge off |
2.72 |
2.80 |
2.88 |
V |
|||
Over discharge protection delay time |
Td1 |
/ |
0.5 |
1.0 |
3.0 |
S |
||||
Over discharge protection release voltage |
Vd2 |
/ |
2.90 |
3.00 |
3.10 |
V |
||||
Discharge protection recovery condition |
/ |
/ |
Each string of batteries is higher than the over-discharge release voltage, disconnecting the load or operating the weak current switch to recover |
|||||||
Over current protection |
over current 1 protection current value |
Ioc1 |
/ |
80 |
90 |
100 |
A |
|||
Over current 1 protection delay time |
Toc1 |
/ |
50 |
300 |
500 |
mS |
||||
Discharge current release |
Over current protection recovery condition |
/ |
/ |
Disconnect the load or operate the weak current switch to recover. |
||||||
Discharge current |
Continuous discharge current |
Ioc |
/ |
/ |
/ |
30 |
A |
|||
Short circuit |
short circuit protection delay time |
Tshort |
/ |
150 |
300 |
1000 |
uS |
|||
Short circuit protection recovery |
/ |
/ |
Disconnect the load or operate the weak current switch to recover |
|||||||
Internal resistance |
discharge circuit internal resistance (mΩ) |
Ron1 |
/ |
/ |
15 |
50 |
mΩ |
|||
Self-consumption power |
Single-section self-consumption current |
Icc1 |
/ |
/ |
30 |
50 |
uA |