Enquiries
Message
Home > Products > Electrical Equipment & Supplies > Other Electrical Equipment
High Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer
  • High Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer

High Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meo wig Trading Co., Ltd
Meo wig Trading Co., Ltd
China - Hangzhou
Manufacturer
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
51-100 people
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
BRC
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Zhejiang, China
Brand Name:
YOMIN
Model Number:
MSQ-30-75/5
Coil Structure:
TOROIDAL
Phase:
Single
Usage:
Current
Coil Number:
15 turns
Current Ratio:
75/5A
Accuracy:
Class 1.0
Max System Voltage:
720V AC
Frequency:
50/60Hz
Continuous Overload:
1.2 x In.
Test Voltage:
3kV AC (1min.)
Security Factor:
FS<5
Index of Casing Insulation:
Class B
Working Temperature:
-25℃ ~ +50℃
Standards:
IEC60044-1, VDE0414-44-1, BS3938, BS7626
Supply Ability
Supply Ability:
100000 Piece/Pieces per Month
Packaging & Delivery

High Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer

 

 

High Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer from China supplier 

 

Product Overviews

 

Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They're connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT.

 

 

 

  • Measuring CT: Measuring current transformers are constructed to feed on other low voltage apparatus such as measuring instruments, relays, watt-hour meter (KW meter) and these type of current transformers are mainly used 0.5 and 1.0 class to transfer the current from highest rated current to rated secondary current.

 

  • Protection CT: Protection current transformers are constructed to feed the protection relay. These type of current transformers are mainly used 5P. (Customer supplied when required.)
 
 
 
 

 

Selection of the Current Transformer

 

To select the current transformer correctly, the following points should be clarified:

  • -The application (for measuring or protection).
  • -The features of the working environment (Indoor or outdoor, operating temperature, air humidity etc….).
  • -Operation voltage and frequency.
  • -Range of the primary current (maximum and minimum of the current to be measured).
  • -Dimension of the cable or Bus bar.
  • -Data of the overload.
  • -Short circuit current.
  • -Specification of the measuring device associated with the current transformer (Accuracy, rated current, consumption etc…).
  • -The diameter and length of the cable, the cable which is used to connect the current transformer and associated measuring device.

Power Losses of the CT

 

In the practical application, the power generated by the primary current should be equal or bigger than the power requirement of the associated measuring device plus the consumption of the connecting line.

 

Losses in the line, PL:

This is the power loss, through heat, generated by current through the resistance RL in the cable, in the transformer’s secondary circuit.

 

Factors to be taken into account:

Secondary current: PL = RL / 2

 

Cable diameter: RL is inversely proportional to the square of the diameter cable length: RL is proportional to the length of cabling (there and back).

 

Power: The nominal apparent power (VA) with a specified power factor, which was supplied by the Current Transformer, to the secondary current with the assigned current when it is connected to its nominal load. Sc (VA) = Zc (/sn)2 According to Standards, for apparent power greater than or equal to 5VA, the power factor is 0.8 inductive. For apparent power less than 5VA the power factor is considered to be one (unity).

 

 

Accuracy of A Current Transformer

 

The percentage of error, produced in a transformer, is established by IEC60044-1. In measurement transformer: 25% and 100% of nominal power. In protection transformers: 100% of nominal power.

 

Note: with…/1A transformers losses are reduced 25 times.

 

 

Saturated Condition of CT

The current transformer is saturated if the primary current, passing through the CT, is greater than the nominal rating of the CT.

 

The linearity of CT, between the primary and secondary sides decreases, so error increases. The saturation of the CT is inversely proportional to the load (FIG. 1).

 

The difference between measuring and protection current transformers is their behavior when an overload occurs on the primary side. Measuring CT is saturated when there is a primary current overload. In order to protect the equipment. On the secondary side, protection CT will not saturated until there is a very high current on the primary side, A class 5P15 protection transformer indicates that it has an accuracy rating of ±1% that it does not become saturated until the primary current reaches 15 times the nominal current rating of the CT.

In measuring transformers, the SAFETY FACTOR “FS” parameter indicates the excessive amperage on the primary side current in relation to the current sent to the measuring device on the secondary side.

 

 

 

 

 

Application Note

 

If the primary current is too small, to keep the same accuracy and output, we can add primary winding, but the rated turns ration should be the same, For example, if the primary current is 50A, we can use 100/5A current transformer with the primary current be turned twice which help to keep the same rated turns ratio (1:50 = 2:100).

 

 

 

 

 

Construction

 

CT consist of primary winding, secondary winding, magnetic core and insulated body. The high-grade silicon steel core is annealed, varnished then insulated with polycarbonate core caps. The secondary winding is toroidally wound by high precision semi-automatic machinery. For the tape wound ring type current transformer, the PEW coated windings are then covered with elephantite paper, varnished and double-tapped with PVS tapes. For the encapsulated type current transformer, the windings are enclosed in a compact and heat resistant split cap.

 

 

 

 

Specifications
 

 

 

 

  • Current Ratio..................................................................................75/5A
  • Accuracy.........................................................................................Class 1.0
  • Burden.............................................................................................See Selection Form.
  • Security Factor................................................................................FS<5
  • Max System Voltage.......................................................................720V AC
  • Test Voltage.....................................................................................3kV AC. (1 min.)
  • Frequency........................................................................................50/60Hz
  • Rated Short-time Thermal Current (Ith)........................................Ith = 60 X In
  • Rated Dynamic Current (Idyn).......................................................Idyn = 2.5 X Ith
  • Continuous Overload.....................................................................1.2 X In
  • Working Temperature....................................................................-25°C ~ +50°C
  • insulation Rating.............................................................................Class B
  • Housing Self-extinguishing Class.................................................VO
  • Bus-bar Support Mounting.............................................................Provided
  • Panel Mounting................................................................................Provided
  • Hinged Sealable Terminal Cover....................................................Provided
  • Standards.........................................................................................IEC/EN60044-1, VDE0414-44-1, BS3938, BS7626

 

Selection Form

 

ItemCurrent RatioRated Burden (VA)Case Qty.
Model(A)Class: 0.5Class: 1.0(Pcs)
MSQ-3030/5-1.5 (3T)60
MSQ-3040/5-1.5 (2T)60
MSQ-3050/5-2.5 (2T)60
MSQ-3060/5-2.5 (2T)60
MSQ-3075/5-1.560
MSQ-3080/5-1.560
MSQ-30100/5-2.560
MSQ-30150/5-3.7560
MSQ-30200/55560
MSQ-30250/557.560
MSQ-30300/5101060

 

Dimension

 

 

High Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer from China supplier

 

1 Where is your factory?

Our factory is located in Qiaoqian Industry Area, Liushi Town, Yueqing City, Zhejiang Province, 325603 China.

2 Are you manufacturer or business?

We are manufacturer established in 2002, and have over 16 years production experience.

3. Can I ask for samples?

Yes 

4. What's the warranty of your products?

18 months

5. What's the lead time?

Depend on the quantity and model of the order, normally it takes around 2-3 days, but the exact lead time should be discussed  with our sales.

6. How about the MOQ, Payment term, Delivery port, and shipping date?

1)MOQ: 100 pcs/item based on existing packing.

2)T/T-30% deposit and 70% against copy of BL

3)L/C is also acceptable

4)Ningbo/Shanghai

 

High Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer from China supplier

High Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer from China supplierHigh Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer from China supplierHigh Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer from China supplierHigh Accuracy MSQ 100/5A 0.5 class Low Voltage Electric Current Transformer from China supplier

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToEmily Li
Meo wig Trading Co., Ltd
Enquire
Related Categories
Connectors&TerminalsContactorsFuseComponentsFusesPowerDistributionEquipmentTransformers
Popular Searches
tea bottling equipmentmodern dental lab equipmenttai chi equipmentholistic equipmentspeed skating equipmenthdpe electrical conduittyre service equipmentbin cleaning equipmentelectrical tajinegeotechnical equipmentused anesthesia equipment0 electrical wireschiller medical equipmentkernel medical equipmentelectrical turtlelowes electrical outletsreception equipmentecu laboratorial equipmentthermodynamics lab equipmentpaint testing equipmentice cream truck equipment0.3mm electrical wire0.3mm electrical wireink testing equipmentland leveling equipmentfan testing equipmentbeef jerky equipmentwater leak testing equipmentsteel plate handling equipmenttextile lab equipmentrubber vulcanizing equipmentround electrical ovencar electrical switchestj electrical socketmold lifting equipmentspark testing equipmentsolar lab equipmenthair salon electrical equipmentoven cleaning equipmentused rescue equipment