HCL leak gas detector hydrogen chlorine alarm detector with 4-20mA output
Product Overview:
KQ500D series gas detector with LED display transforms the gas density in the operating site into standard electric current signal(4-20mA).
KQ500D has excellent performance, stable operation, easy maintenance. since detector also can detect various gas, it meet various requirements in the operation site; it has been widely used in petrol, chemistry, metallurgy, artifice, gas transportation, biological medicine and water procession etc.
Main features:
l Standard 4-20mA electric current output, compatible with existing alarm control unit or DSC (distributed control system).
l LED site display
l Standard three buttons: so an individual can operate the detector in site.
l Automatic identify and display the sensor failures, and output the corresponded current signal at the same time.
l The key operation needs to input password to prevent wrong operation.
l Simple calibration function; reducing measuring error
l Two levels' light alarm, relay output (connected with audible and visual alarm outside or start the exhaust system)
Technical Parameters:
Detecting Gas | HCL; Hydrogen chlorine |
Measuring Range | 0-20ppm |
Working Voltage | 24V DC±15% |
Signal output | 4~20mA linear current output; or RS485 signal output (optional) |
Deviation | ≤± 3% F.S |
Respond Time | T90 < 30 s |
Recovering time | ≤ 30 s |
Display model | LED display |
Working Temperature | toxic gas: - 20 °C ~ + 50 °C Combustible gas: - 40 °C ~ + 70 °C |
Working Humidity | 10-95% R.H.(no condensation) |
Explosion-proof level | Exd IICT6(used for explosion proofing detector); ExiaIICT4(used for intrinsic safety type detector) |
Protection Class | IP66 |
Transition cable | three core shield cable RVVP 3×1.5mm2; 4×1.5mm2 |
Transmission distance | ≤1000m |
Weight | about 1.5kg |
Product Information Chart
Product Model | Detected Gas | Measuring Range | Resolution | Respond Time (T90) | Low Alarm | High Alarm |
KQ500D-O2 | O2 | 0-30%vol | 0.1%vol | ≤15s | 18.5%vol | 23%vol |
KQ500D-CO | CO | 0-1000ppm | 1 ppm | ≤15s | 50ppm | 150ppm |
KQ500D-H2S | H2S | 0-100ppm | 1 ppm | ≤15s | 10ppm | 15ppm |
KQ500D-HCN | HCN | 0-20ppm | 0.1ppm | ≤30s | 5ppm | 10ppm |
KQ500D-CL2 | CL2 | 0-20ppm | 0.1 ppm | ≤30s | 2ppm | 5ppm |
KQ500D-O3 | O3 | 0-5ppm | 0.01 ppm | ≤25s | 0.1ppm | 0.5ppm |
KQ500D-NH3 | NH3 | 0-200ppm | 1 ppm | ≤30s | 25ppm | 50ppm |
KQ500D-H2 | H2 | 0-1000ppm | 1 ppm | ≤30s | 50ppm | 200ppm |
KQ500D-NO2 | NO2 | 0-20ppm | 0.1 ppm | ≤25s | 2ppm | 5ppm |
KQ500D-PH3 | PH3 | 0-20ppm | 0.1 ppm | ≤15s | 1ppm | 3ppm |
KQ500D-C3H3N | C3H3N | 0-100ppm | 1ppm | ≤30s | 5ppm | 15ppm |
KQ500D-NO | NO | 0-250ppm | 1ppm | ≤25s | 35ppm | 50ppm |
KQ500D-HCL | HCL | 0-20ppm | 1ppm | ≤25s | 3ppm | 5ppm |
KQ500D-SO2 | SO2 | 0-20ppm | 0.1ppm | ≤15s | 2ppm | 5ppm |
KQ500D-CO2 | CO2 | 0-5000ppm | 1ppm | ≤30 s | 1000ppm | 2000ppm |
0-5.00%vol | 0.01%vol | 1.00%vol | 2.00%vol | |||
KQ500D-EX | combustible gas | 0-100%LEL | 1%LEL | ≤30s | 20%LEL | 50%LEL |
As for unlisted detected gas and measuring range, please contact with our company |