Enquiries
Message
Home > Products > Other
Good quality medical Nitrous Oxide N2O demand valve with Mini brass regulator and hose
  • Good quality medical Nitrous Oxide N2O demand valve with Mini brass regulator and hose

Good quality medical Nitrous Oxide N2O demand valve with Mini brass regulator and hose

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Warranty:
12 months, 12 Months
Customized support:
OEM
Place of Origin:
Shaanxi, China
Brand Name:
FLN
Model Number:
PR
Product name:
Nitrous Oxide demand valve
Suitable gas:
N2O Gas
Material:
brass
Inlet connection:
CGA870
Outlet connection:
Diss
Max Inlet Pressure:
3000psi
Outlet Pressure Ranges:
50psi fixed
Flow range:
0-15L/min
Weight:
0.5kg
Packaging & Delivery
Product Description

 

 

OXYGEN FLOW CONTROL REGULATORS

Oxygen flow control regulators are pressure reducing devices which lower oxygen pressure from a cylinder, to levels that can be safely used by the end user.

Oxygen flow control regulators are intended for the administration of oxygen to patients who need increased oxygen levels to improve their breathing conditions. In addition, some models may  be used in emergency situations. In an emergency situation, be sure to contact a physician or EMS immediately.

TYPE

INPUT PRESSURE

OUTPUT PRESSURE

OUTPUT CONNECTION

FLOW RANGE

CGA870

3000psi Max

50psi Fixed

DISS/Barb/Quick Adapter

0-2L/min, 0-4L/min, 0-8L/min, 0-15L/min

0-25L/min

CGA540

3000psi Max

50psi Fixed

DISS/Barb/Quick Adapter

0-2L/min, 0-4L/min, 0-8L/min, 0-15L/min

0-25L/min

 

Set-up(CGA870 style)

1.      Inspect the cylinder following the instructions of your gas supplier. Be sure to purge the cylinder valve seat of debris.

2.      Inspect the regulator for oil grease. If these are visible, do not use the regulator.

3.      Be sure the sealing washer is in place n the inlet to the regulator.

4.      Slip the Yoke over the cylinder post and fit the pins into the holes on the cylinder valves. The pins should fit easily into the holes.

5.      Tuen the T-handle clockwise until the screw point is seated in the dimple on the cylinder valve. Be sure the regulator is tightened securely onto the cylinder.

6.      Attach the oxygen supply tubing to the outlet connection of the regulator.

Set-up(CGA540 style)

1.      Inspect the cylinder following the instructions of your gas supplier. Be sure to purge the cylinder valves seat of debris.

2.      Inspect the regulator for oil or grease, if these are visible, do not use the regulator.

3.      Gently thread the large nut on the regulator onto the connection on the cylinder valve.

4.      Tighten the nut with a wrench until snug.

5.      Attch the oxygen supply tubing to the outlet connection of the regulator.

Instructions for use:

1.      Be sure the regulator is in the “off” position by rotaing the knob counterclockwise to the “0” position.

2.      For safety, be sure you are not directly in front of or behind the regulator when opening the cylinder valve.

3.      Slowly turn the cylinder valve on(counterclockwise), about one full turn.

4.      If you can hear a hissing sound, there is a leak in the system, turn the cylinder off and turn the regulator on to relieve any built up pressure. Try tightening the regulator to the cylinder and open the cylinder again. If this does not help, shut the system down again and contact a service representative. Never attempt to repair a regulator or cylinder yourself.

5.      Adjust the flow rate setting by turning the knob clockwise until the desired setting shows through the window.

6.      If the cylinder pressure falls below 300 psi, you should exchange the cylinder for a full one.

7.      Turn off the system, close the cylinder valve, wait for oxygen to flow out of the regulator, and turn the regulator to the “0” position.

8.      Never try to remove the regulator unless the cylinder is off and pressure has been relieved.

product category

 

Related Products

 

usage scenario

 

 

Buyer Feedback

 

 

Packaging & Shipping

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher