Enquiries
Message
Home > Products > Other
Gas Chromatography with Chromatographic Column
  • Gas Chromatography with Chromatographic Column

Gas Chromatography with Chromatographic Column

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Warranty:
1 year
Customized support:
OEM
Place of Origin:
Chongqing, China
Brand Name:
Drawell
Sample Introduction System:
sample injector and evaporation chamber
Temperature range:
Ambient temperature +7℃ ~ 400℃ (in 1℃ increment)
Temperature accuracy:
± 0.02℃
Cooling time:
400℃ to 50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting:
0.1℃~40℃/min (in 1℃ increment)
Program ramps:
7 ramps in total (10 ramps available with control workstation)
Detection limit:
≤3*10-12g/s (C16)
Best test result:
≤3*10-12g/s (C16)
Drift:
≤6*10-13A/30min
Noise:
≤5*10-14A
Certification:
ISO
Packaging & Delivery

DW-GC1120 Gas Chromatography

                                     

Temperature Control :

Temperature Range:7℃ ~ 400℃ above room temperature, (increment 1℃)

Temperature Control Object:Column Box, front and back detector, front and back sampler, assist,total six channels.

Program ramps : 7 ramps in total

Program setting:0.1℃~40℃/min(increment 0.1℃)

Total time of total program : Up to 655 minutes, (increment 0.1℃)

 

Hydrogen flame ionization detector (FID):

Minimum detectable quantity: M≤8×10-12g/s (C16)

Best test result: M≤3×10-12g/s (C16)

Noise: ≤5×10-14A

Drift: ≤6×10-13A/h

Linearity range: ≥106

 

Thermal conductivity detector(TCD):

Sensitivity:≥5000mV mL/mg (C16)

Noise: ≤20µV

Drif: ≤30µV/h

Linearity rang: ≥104

 

High Sensitivity Thermal conductivity detector(HTCD):

Sensitivity: ≥10000mV mL/mg (C16)

 

Electron capture detector(ECD):

Detectability: ≤1×10-13g/s  (γ-666)

Linearity range: ≥103

Maximum using temperature:  350℃

 

Flame photometric detector(FPD):

Detectability: ≤2×10-11g/s(P)  (Parathion-methyl)

            ≤1×10-10g/s(S)  (Parathion-methyl)

 

Nitrogen-phosphorus detector(NPD):

Detectability: ≤5×10-12g/s(N)  (Azobenzene)

            ≤5×10-13g/s(P)  (Malathion)

(On programmed)

 

Photoelectric ion detector(PID):

Detectability: ≤1ppb             (Benzene)

 

Optional Parts

Main function

GC1120-TCD

Thermal conductivity detector  

GC1120-ECD

Electron capture detector

GC1120-FPD

Flame photometer detector

GC1120-NPD

Nitrogen phosphorous detector

Chromatographic work station

External interface box + work station (not include PC)

Simulation software

Imitation find chromatographic condition, emulation teaching, train and knowledge base. 


Instrument technical index

Flexible Sample Introduction System

Up to three injectors may be installed and operated simultaneously with independent temperature control. Wide range of injectors is available to be chosen from for various applications. It is very convenient for installation and disassembly of sample injectors.

Sample Injector with Mono Packed Column/Double Packed Columns:

Several alternative sample introduction methods, including on-column sample introduction and six-way valve injection;

Adapter for injection to capillary column (0.53 mm i.d.).

Sample injector for capillary column

Special sample injector with septum purge and back-pressure valve splitting;

Special programmable split/splitless injector with solenoid valve, septum purge, back-pressure valve splitting, and standalone carrier gas and make-up gas flow;

Modified dual-packed-column sample injector for injection to capillary column by employing some connectors and back-pressure valve splitting.

 

Advanced Pneumatics

Carrier gas control with constant pressure valve and constant flow valve;

Air and hydrogen control with constant pressure valve and needle valve;

Flow easily adjustable through constant flow valve and needle valve with digital display;

High precision, reproducibility and reliability.

 

Sensitive and reliable detector

Up to three detectors (FID, TCD, ECD, etc) may be installed and operated simultaneously. Simultaneous multi-detection with detectors in series or in parallel meets the various analysis requirements.

The new FID provides higher sensitivity than ever before. It is very convenient to disassemble and clean the jet and collector. Precisely fixed emitter configuration ensures conformity of product performance;

Excellent TCD detector with high-resistance tungsten-rhenium filaments provides high sensitivity. A sensitivity of 10000 mV·mL/mg is achieved with optional amplifier circuit board. Special configuration of air heat insulation enhances the stability of TCD detector

Constant-current, pulse-modulated ECD detector sets sensitivity and current by computer.

 

Advanced Microcomputer Control System

With advanced control techniques, microcomputer-based temperature control system provides superior performance.

High temperature precision (± 0.5℃), high reliability, and high resistance to disturbance;

Five independent heated zones, with maximum operating temperature of 400℃;

Temperature-limit setting and overheat protection.

Instrument control is accomplished through the keypad, and the instrument offers outstanding capabilities.

Self-diagnosis;

Power-off protection;

Ten methods saving and reloading;

Two controls of external events;

Timing on/off of temperature control;

Timing program, detector status, measurement range, polarity and current setting and display;

Temperature setting values, actual values, retention time and analysis time display.

 

High-performance spacious column oven

Spacious column oven accommodating capillary column and dual packed columns and convenient for column installation;

Fast heat-up and rapid cool-down column oven with automated back-door opening (300℃ to 50℃ in 7 min);

Available for both near-ambient and above ambient temperature control;

Supports 5 oven ramps with 6 plateaus.

Product Description

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher