Enquiries
Message
Home > Products > Measurement & Analysis Instruments > Electrical Instruments > Battery Testers
GF102 Energy Meter Test Calibration Bench single phase electrical energy meters calibration
  • GF102 Energy Meter Test Calibration Bench single phase electrical energy meters calibration

GF102 Energy Meter Test Calibration Bench single phase electrical energy meters calibration

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meo Textile Clothing Co.LTD
Meo Textile Clothing Co.LTD
China - Hangzhou
Manufacturer
Trade Capacity
Export Percentage
Nearest Port
shanghai,ningbo
Accepted Delivery Terms
Employees
101-200 people
Accepted Payment Currency
USD,CNY
Average Lead Time
60 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Beijing, China
Brand Name:
GFUVE
Model Number:
GF102
Phase:
Single Phase
Measuring Energy Range:
0V -264V
Accuracy Class:
0.05%, 0.1%
Output Voltage:
57.7V, 100V, 220V, 380V; max 500V
Operating Temperature:
-10°C to +40°C
Dimensions:
455*440*150
Meter under testing:
1P2W
Accuracy class:
0.05%, 0.1%
AC Voltage Output:
57.7V, 100V, 220V, 380V; max 500V
AC Current Output:
200mA, 1A, 5A, 20A, 100A; max 120A
Phase Output:
0°-359.999°
Frequency Output Adjustment range:
40Hz-70Hz
Voltage /Current/Harmonic Setting:
2-51times
Testing mode:
active power, reactive power
Supply Ability
Supply Ability:
200 Set/Sets per Month
Packaging & Delivery
Product Description

 GF102 PORTABLE SINGLE PHASE ENERGY METER TEST BENCH

GF102 portable single phase energy meter testing bench used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage and current output. Widely used in lab and field, and then as single phase standard source.

 

Features

 

  • Meter under testing: 1P2W
  • 2Testing mode: active power, reactive power
  • Test 3pcs or 2pcs meter synchronously
  • Start testing and creep testing
  • Reference standard and power source integrated, easy to carry
  • Measuring mechanical meter and electric meter
  • Operating by manual keyboard or PC software
  • With keyboard shortcuts
  • Internal large capacity storage device for mass memory
  • Local checking the testing result
  • Overload, short circuit, open circuit protection
  • With self-checking function
 
Parameters

 

lectrical parameters
Accuracy class  0.05%, 0.1%
Power supply One Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output
Range 57.7V, 100V, 220V, 380V; max 500V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.1% (Non-capacitive load)
Output load max 25VA
Measuring accuracy 0.05%RG
AC Current Output
Range 200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.1% (Non-capacitive load)
Output load max 50VA
Accuracy 0.05%RG
Power Output
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy 0.1%RG
Phase Output
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.05°
Power Factor
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0. 0005
Frequency Output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.005Hz
Voltage /Current/Harmonic Setting
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power Pulse Output
Power pulse type active pulse, reactive pulse
Active power pulse output 5V,10mA
Power Pulse Input
Energy pulse type support active and reactive pulse, the highest frequency
power pulse input is 180K.
Mechanical parameters
Dimensions (W×D×H) (mm) 455x440x150
Weight (kg) 12
Environmental conditions
Ambient temperature -10°C to +40°C
Relative humidity 35%-85%
(1)RG means range, the same as below;
(2)RD means the setted harmonic content, harmonic can be a single output,also multiple output.
Certifications

 

Packaging & Shipping

 

Our Services

 

Company Information

 

No desirable products?
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToEric Zhang
Meo Textile Clothing Co.LTD
Enquire
Related Categories
CurrentMetersFrequencyMetersMultimetersPotentiometersPowerMetersResistanceMeters
Popular Searches
flat cut lettersbattery vent capsanitary gasketscemetery planterswater doserglitter coastersbattery pentaxbattery heater fanaqua water heatershioki battery tester0 18v battery testerbattery regeneratorbattery 48d26rbattery scooterbattery led standoffbattery concealerglitter starsbattery for asusland battery testeralabaster coastersbattery refreshergantry systemstator testerbattery for tecnobattery ph meterbattery vas 5052battery heated vestbattery for uberbattery pigeonbattery for pajerobattery extenderartery forcepsbattery rebar cutterhammer casterwalter insertsbattery xenoev battery testeraster tonersscatter tubes urns2v battery load tester