Enquiries
Message
Home > Products > Other
GC1120 Laboratory Gas Chromatograph Equipment Gas Chromatography Analyzer
  • GC1120 Laboratory Gas Chromatograph Equipment Gas Chromatography Analyzer

GC1120 Laboratory Gas Chromatograph Equipment Gas Chromatography Analyzer

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Warranty:
1 years
Customized support:
OEM
Place of Origin:
China
Brand Name:
Drawell
Model Number:
GC1120
Sample Introduction System:
sample injector and evaporation chamber
Temperature range:
Ambient temperature +7℃ ~ 400℃ (in 1℃ increment)
Temperature accuracy:
± 0.02℃
Cooling time:
400℃ to 50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting:
0.1℃~40℃/min (in 1℃ increment)
Program ramps:
7 ramps in total (10 ramps available with control workstation)
Size (L*W*H):
340*345*281mm(outside)
Detector:
FID/ FPD/ NPD
Power Supply:
AC220V/50Hz/60Hz
Certificate:
ISO, CE
Certification:
ISO, CE
Supply Ability
Supply Ability:
200 Piece/Pieces per Month
Packaging & Delivery
Product Description

 

DW-GC1120 Gas Chromatography

Features

Control system: designed for monitoring and controlling the instrument via the computer.

Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system”)

Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control

Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening. (400℃ to 50℃ in 6 min at 25℃ cambient)

Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.

High sensibility and stability detector.

2 independent and analog signals output.

M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations.     (electronic records and signatures)

 

Gas chromatography and accessories

Superior performance with advanced, microcomputer-based temperature control system

High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference

Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)

Intuitive display of timing program, detector status, measurement range, current setting, etc

Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector

Carrier Gas System: air source/ purification and desiccation device/ flow rate control device

Sample Introduction System: sample injector

Separation System: chromatographic column(packed column and capillary column)

Temperature Control System (Column Oven): constant temperature and programmed temperature

Detector: FID/ FPD/ NPD

 

Advanced Microcomputer Control System

Gas chromatography and accessories

Superior performance with advanced, microcomputer-based temperature control system

High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference

Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)

Intuitive display of timing program, detector status, measurement range, current setting, etc

 

Model#  DW-GC1120
Sample Introduction System sample injector and evaporation chamber

Column 

Oven

Temperature range Ambient temperature +7℃ ~ 400℃  (in 1℃ increment)
Temperature accuracy  ± 0.02℃
Cooling time 400℃ to 50℃ in 8-10 min at 25℃ ambient

Programmed 

temperature setting

0.1℃~40℃/min (in 1℃ increment)
Program ramps 7 ramps in total (10 ramps available with control workstation)
Size (L*W*H) 284*280*241mm(inside) 340*345*281mm(outside)

Flame 

Ionization 

Detector 
(FID)

Detection limit ≤3×10-12g/s (C16) 
Best test result ≤3×10-12g/s (C16)
Drift ≤6×10-13A/30min
Noise ≤5×10-14A
Linearity range ≥106

Thermal 

Conductivity 

Detector
(TCD)

Sensitivity ≥5000mV, mL/mg (C16)
Baseline noise ≤20µV
Drift ≤60µV/h
Linearity range ≥104

Flame 

Photometric 

Detector
(FPD)

Detection limit ≤8×10-13g/s(P) ; ≤8×10-11g/s(S)
Drift ≤2×10-11A/30min
Baseline noise ≤5×10-12A

Nitrogen-

Phosphorus 

Detector
(NPD)

Detection limit ≤5×10-12g/s(N)  (Azobenzene)
            ≤5×10-13g/s(P)  (Malathion)

 

 

Hot Products

 

Company Information

 

Packaging & Shipping

 

Contact Us

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher