Features: 1. Simulate standard open airway and sound prompting 2. External breast compression: indicator light display, digital counter display and sound prompting a) Indicator light display of correct and wrong compression position; digital counter display; sound prompting of wrong compression. b) Display of correct (at least 5cm) and wrong (less than 5cm) compression intensity; digital strip indicator light (yellow, green, red) shows compression depth; counter display; sound prompting of wrong operation. 3. Artificial respiration (Inhalation) indicator light display, digital counter display and sound prompting: a) Inhalation is ≤500ml/600ml-1000≤, strip indicator light shows inhalation volume; counter display of correct and wrong operations, and sound prompting of wrong operation. b) Inhalation too quickly or too much result in air entering into stomach; indicator light display; digital counter display; sound prompting. 4. Ratio of compression and artificial respiration: 30:2 (one or two person) 5. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration. 6. Operation frequency: at least 100 times per minute 7. Operation methods: exercise operation; examine operation 8. Operation time: counting down device 9. Sound prompting device: volume control; turning on or turning off sound prompting device 10. Print: print operation result 11. Examination of pupil response: mydriasis and myosis 12. Examination of carotid response: simulate spontaneous carotid pulse in compression process 13. Working conditions: Input power is 110-240V
Standard components: 1. Full body manikin (1) 2. Monitor (1) 3. Portable plastic box (1) 4. Temperature sensing printer (1) 5. CPR operation pad (1) 6. CPR face shield sheet (50pcs/box) 7. Exchangeable lung bag (5) 8. Exchangeable face skin (1) 9. Temperature sensing print paper (2 roll) 10. Guide manual (1)
Features: 1. Simulate standard open airway and sound prompting 2. External breast compression: indicator light display, digital counter display and sound prompting a) Indicator light display of correct and wrong compression position; digital counter display; sound prompting of wrong compression. b) Display of correct (at least 5cm) and wrong (less than5cm) compression intensity; digital strip indicator light (yellow, green, red) shows compression depth; counter display; sound prompting of wrong operation. 3. Artificial respiration (Inhalation) indicator light display, digital counter display and sound prompting: a) Inhalation is ≤500ml/600ml-1000≤, strip indicator light shows inhalation volume; counter display of correct and wrong operations, and sound prompting of wrong operation. b) Inhalation too quickly or too much result in air entering into stomach; indicator light display; digital counter display; sound prompting. 4. Ratio of compression and artificial respiration: 30:2 (one or two person) 5. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration. 6. Operation frequency: at least 100 times per minute 7. Operation methods: exercise operation; examine operation 8. Operation time: counting down device 9. Sound prompting device: volume control; turning on or turning off sound prompting device 10. Print: print operation result 11. Examination of pupil response: mydriasis and myosis 12. Examination of carotid response: simulate spontaneous carotid pulse in compression process 13. Working conditions: Working conditions: Input power is 110-240V or adopts direct current of eight No.1 batteries.
Standard components: 1. Full body manikin (1) 2. Monitor (1) 3. Portable plastic box (1) 4. Temperature sensing printer (1) 5. CPR operation pad (1) 6. CPR face shield sheet (50pcs/box) 7. Exchangeable lung bag (5) 8. Exchangeable face skin (1) 9. Temperature sensing print paper (2 roll) 10. Guide manual (1)