Structure | Unit | Parameter | ||||||||
Fiber Counts | Fibers | 4-30 | 32-60 | 62-72 | 74-84 | 86-96 | ||||
Element | -- | 5 | 6 | 7 | 8 | |||||
Loose Tube Diameter | mm | 1.75 | 2.05 | 2.05 | 2.1 | 2.1 | ||||
Cores of per tube(no more than) | -- | 6 | 12 | |||||||
Central Steel Wire/PE Sheath(if required) | mm | 1.4 | 1.6 | 2.2 | 1.8(2.9) | 1.8(3.5) | ||||
Cable Diameter(Nom.) | mm | 9.1 | 10.0 | 10.5 | 11.2 | 11.8 | ||||
Weight(Approx.) | Kg/Km | 139 | 152 | 177 | 180 | 190 |
Structure | Unit | Parameter | ||||||||
Fiber Counts | Fibers | 98-108 | 110-120 | 122-132 | 134-144 | 146-216 | ||||
Element | -- | 9 | 10 | 11 | 12 | 6/12 | ||||
Loose Tube Diameter | mm | 2.1 | 2.1 | |||||||
Cores of per tube(no more than) | -- | 12 | ||||||||
Central Steel Wire/PE Sheath(if required) | mm | 1.8(4.2) | 1.8(4.6) | 2.0(5.5) | 2.2(6.1) | 2.2 | ||||
Cable Diameter(Nom.) | mm | 12.7 | 13.3 | 14.0 | 14.7 | 15.4 | ||||
Weight(Approx.) | Kg/Km | 205 | 223 | 238 | 257 | 276 |
Corrugated Aluminum Tape | -- | YES | ||
Self-support part | mm | Self-support part diameter 3.0mm(1.0mm*7) | ||
Central Strength Member | -- | Steel strength member | ||
Tension Strength (Long/Short Term) | Long Term | N | 3000 | |
Short Term | N | 8000 | ||
Crush Resistance (Long/Short Term) | Long Term | N | 300 | |
Short Term | N | 1000 | ||
Bending Radius | Dynamic | -- | 10 times Cable Diameter | |
Static | -- | 20 times Cable Diameter | ||
Storage/Operating Temperature | Operation | -40℃ to 60℃ | ||
Application | -- | Long-distance Communications |