Use and structure characteristic
The BK series engine bed control transformer (hereafter refers to as transformer) to besuitable the 50-60Hz voltage to in the 500V electric circuit, usually serves asthe engine bedcontrol electric appliance or the partial flare and the indicating lamp using of power source.The BK transformer structure may divide into the shell type, according to installs the way se-parable for vertical.
BK Series Outline and Installation Dimension
Model | Power (VA) | External | Installs the size | Installment hole | ||||
Bmax | Dmax | Emax | A±0.4 | C±1.5 | K | J | ||
BK-25 | 25VA | 76 | 80 | 77 | 65 | 50 | 5 | 7 |
BK-50 | 50VA | 87 | 94 | 87 | 70 | 60 | 6 | 8 |
BK-100 | 100VA | 108 | 95 | 101 | 85 | 65 | 6 | 8 |
BK-150 | 150VA | 108 | 100 | 101 | 85 | 75 | 6 | 8 |
BK-200 | 200VA | 108 | 107 | 101 | 85 | 80 | 6 | 8 |
BK-250 | 250VA | 115 | 110 | 125 | 90 | 95 | 8 | 11 |
BK-300 | 300VA | 115 | 115 | 125 | 90 | 100 | 8 | 11 |
BK-400 | 400VA | 135 | 140 | 140 | 110 | 100 | 8 | 11 |
BK-500 | 500VA | 135 | 145 | 140 | 110 | 105 | 8 | 11 |
BK-800 | 800VA | 155 | 150 | 160 | 125 | 119 | 8 | 11 |
BK-1000 | 1000VA | 155 | 160 | 160 | 125 | 130 | 8 | 11 |
BK-1500 | 1500VA | 180 | 220 | 180 | 143 | 150 | 8 | 11 |
BK-2000 | 2000VA | 180 | 240 | 180 | 143 | 175 | 8 | 11 |
BK-2500 | 2500VA | 210 | 230 | 240 | 185 | 175 | 8 | 11 |
BK-3000 | 3000VA | 210 | 245 | 240 | 185 | 190 | 8 | 11 |
BK-4000 | 4000VA | 250 | 250 | 280 | 195 | 170 | 8 | 11 |
BK-5000 | 5000VA | 250 | 265 | 280 | 195 | 195 | 8 | 11 |
Applications
Model and meaning
Matters needing attention
1. Before the purchase, first estimates the electric appliance aggregate capacity which youuse. and selects has the suitable capacity transformer, guarantees when the instantaneousstarting does not burn the bad transformer.
2.This transformer strictly according to national related standard design production. Whenyou use the multiwindings (multi control voltage) when transformer, the capacity shouldaccording to the ratiovoltage corresponding increase transformer capacity, in order toavoid burns out the transformer.
3. Before the installment, should examine the data plate to arrange in order each data car-efully whether conforms to your requirement, after confirmed unmistakable, only then installs the use.
4. (But after the circular telegram work, the transformer core and the coil will give off heattemperature rise not to surpass 80C) are the normal phenomenon, ift the temperature risewill surpass 80C, will even belch smoke, then will be supposed the dump switch, to inspectthe electric appliance capacity which you will use.
5. In the transportation,should avoid colliding as far as possible, is sure not to be affectedwith damp, when use, please note maintains, protects the transformer service life.