Enquiries
Message
Home > Products > Other
Epoxy RTV Curing Transformer winding wire Potting Sealant
  • Epoxy RTV Curing Transformer winding wire Potting Sealant

Epoxy RTV Curing Transformer winding wire Potting Sealant

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Shanghai, China
Classification:
Double Components Adhesives
Main Raw Material:
Epoxy
Usage:
Construction, Fiber & Garment, Footwear & Leather, Packing, Transportation, Woodworking
Brand Name:
jorle
Model Number:
ZR112
Product name:
Transformer winding wire sealant
Mixed viscosity:
1000-2000
mixing ration:
4:1
Gel time:
40
Curing time:
80/1.5 or 25/10
hardness:
80
expansion coefficient:
44
water absorption:
<0.1
dielectric strength:
>20
Loss factor:
0.014
Supply Ability
Supply Ability:
50 Ton/Tons per Month Transformer winding wire sealant
Packaging & Delivery

Transformer winding wire sealant

Description:

 

 

 

uZR112 epoxy casting glue is a room temperature/heating curing epoxy resin glue. ZR112 is used for design, protection of the potting need high strength or confidential electronic products.

 

uZR112 epoxy potting materials without heating can cure. 4:1 (weight ratio) completely mixed part A and part B, form protection in a period of curing time.

 

After curing glue has the following characteristics:

 

uAgainst moisture, dirt and other atmospheric composition

 

uHigh strength

 

uHas confidential role   

 

uSolvents, no cure by-products

 

uFireproof performance

 

uHave stable mechanical and electrical properties between -45°C-120°C

 

 

Conventional performance:

 

 

test item

testing standard

unit

A

B

Outside view

visual inspection

---

black viscous liquid

Brown liquid

viscosity

GB/10247-2008

mPa·s(25°C)

10000-25000

100-150

density

GB/T 13354-92

g/cm3(25°C)

1.55

1.14

 

 

Operation process:

 

 

test item

unit

value

mixture ratio

weight ratio

100:25

mixture ratio

volume ratio

100:34

Mixed viscosity

mPa·s(25°C)

1000-2000

Mixture density

g/cm3(25°C)

1.45

Gel time

min(25°C)

40

curing time

°C/hr

80/1.5 or 25/10

 

Operation time is a quantity of cement with 100 g.

 

A, B two components in proportion to remove mixing ratio, mixing, vacuum suction bubble in operation period, remove the potting products to casting, such as potting product is too big, suggest points potting, then according to The Times curing(80°C/90min or 25°C/10hr)

 

 

Operation caution:

 

uAgent A place for a long time, maybe produce precipitation, mix part A and B access should be paid attention to save after sealing.

 

uMixing should pay attention to the same direction, otherwise, it will stir with too much bubble; Borders and the bottom of the container sizing material should also stir well, can appear otherwise stir caused by uneven local not curing phenomenon.

 

uCasting the product vacuum pumping, remove again bubble can improve after curing products comprehensive performance.

 

uTemperature is too low will lead to curing speed partial slow, heat cure advice; Potting thickness more than 2 cm above 80 °C not directly in the curing, lest cause explosive together.

 

uThis glue curing exothermic reaction, match the process as the quantity of cement can affect the operation, so the length of time with 100 g resin content of operation time is only a reference time.

  

Typical performance:

 

 

 

test item

testing standard

Unit

value

hardness

GB/T 531.1-2008

Shore D

80

conductivity factor

GB/T 10297-1998

W/mK

0.4

expansion coefficient

GB/T 20673-2006

μm/(m,°C)

44

water absorption

GB/T 8810-2005

24h,25°C,%

<0.1

flame retardant rating

UL-94

3mm,105°C

V-0(E315820)

dielectric strength

GB/T 1693-2007

kV/mm(25°C)

>20

Loss factor

GB/T 1693-2007

(1MHz)(25°C)

0.014

dielectric constant

GB/T 1693-2007

(1MHz)(25°C)

3.53

volume resistance

GB/T 1692-92

(DC500V)Ω· cm

1.2×1015

 

Remark:All the above data come from 25 °C and 55% RH glue curing conditions after 7 days.

 

 

 

Packing:

 

25 kg /set; 5kg / set; 1kg/ set

 

 

Storage and transportation:

 

 

uPart A and part B need to avoid light, heat, save after sealed. (Can be used as the non-dangerous goods transport and storage)

 

uShelf life Agent A: 1 year, Agent B: 6 months(25°C)

 

 

 

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher