Introduction:
JYLWGY series liquid turbine flowmeter is a kind of speed instrument, which has the advantages of high accuracy, good repeatability, simple structure, small pressure loss and convenient maintenance. It is used to measure the volume flow of low viscosity liquid in closed pipe. In the petroleum, chemical, metallurgy, water supply, paper and other industries with a wide range of applications.
Parameters:
Product Name | Tri-clamp stainless steel liquid water milk turbine flow meter price |
Measuring medium | Liquid(Water,liquefied petroleum gas ,refined oil ,light crude oil ,organic liquid,inorganic liquid and other fiber,particulate impurities of liquid ) |
Nominal diameter | DN4-DN200 |
Accuracy | 0.2%,0.5%,1% |
Nominal pressure | 1.0MPa,1.6MPa,2.5Mpa; 4.0Mpa;6.3MPa, |
Power supply | 3.6V lithium battery; 12VDC; 24VDC; |
Output signal | three-wire pulse output, two-wire 4-20mA output |
Communication Protocol | Hart/RS485 |
Environmental conditionas | Ambient temperature: -20 ℃ ~ +60 ℃; Relative humidity: 5% to 95%; Atmospheric pressure: 86kPa ~ 106kPa; |
Explosion-proof grade | CT-4,CT6 |
Flow Range table
Diameter(mm) | Flow range | Diameter(mm) | Flow Range |
4 | 0.04-0.25m3/h | 50 | 4-40m3/h(standard range) 2-40m3/h(wide range) |
6 | 0.1-0.6m3/h | 65 | 7-70m3/h(standard range) 3-70m3/h(wide range) |
10 | 0.2-1.2m3/h | 80 | 10-100m3/h(standard range) 3.5-100m3/h(wide range) |
15 | 0.6-6m3/h(standard range) 0.3-6m3/h(wide ragne) | 100 | 20-200m3/h(standard range) 7-200m3/h(wide range) |
20 | 0.7-7m3/h(standard range) 0.4-7m3/h(wide range) | 125 | 25-250m3/h(standard range) 8.5-250m3/h(wide range) |
25 | 1-10m3/h(standard range) 0.5-10m3/h(wide range) |
150 | 30-300m3/h(standard range) 10-300m3/h(wide range) |
32 | 1.5-15m3/h(standard range) 0.6-15m3/h(wide range) |
200 | 80-800m3/h(standard range) 25-800m3/h(wide range) |
40 | 2-20m3/h(standard range) 0.7-20m3/h(wide range) |
The flow meter is provided to the control instrument through the flow meter, and the quantitative value is set on the control instrument panel. After the set amount is reached, the solenoid valve, the water pump, etc. are automatically turned off. The solenoid valve can be controlled at the same time, and the pump can also be controlled separately.