Model | XTRA1206N | XTRA2206N | XTRA1210N | XTRA2210N | ||||
Electrical | ||||||||
Nominal System Voltage | 12/24VDC① Auto | |||||||
Rated charge current | 10A | 20A | 10A | 20A | ||||
Rated discharge current | 10A | 20A | 10A | 20A | ||||
Battery Voltage Range | 8V~32V | |||||||
Max. PV open circuit voltage | 60V②/46V③ | 100V②/92V③ | ||||||
MPP voltage range | (Battery voltage +2V)~36V | (Battery voltage +2V)~72V | ||||||
Max. PV input power | 130W/12V 260W/24V | 260W/12V 520W/24V | 130W/12V 260W/24V | 260W/12V 520W/24V | ||||
Equalization Voltage ④ | Sealed: 14.6V; Flooded: 14.8V; User: 17~9V | |||||||
Boost Voltage ④ | Gel:14.2V; Sealed:14.4V; Flooded:14.6V; User: 17-9V | |||||||
Float Voltage ④ | Gel /Sealed /Flooded: 13.8V; User: 17~9V | |||||||
Low Voltage Reconnect Voltage ④ | Gel /Sealed /Flooded: 12.6V; User: 17~9V | |||||||
Low Voltage Disconnect Voltage ④ | Gel /Sealed /Flooded: 11.1V; User: 17~9V | |||||||
Self-consumption | ≤14mA(12V) ; ≤15mA(24V) | ≤35mA(12V); ≤22mA(24V) | ||||||
Discharge circuit voltage drop | ≤0.23V | |||||||
Temperature compensate coefficient | -3mV/℃/2V(Default) | |||||||
Grounding | Common negative grounding | |||||||
RS485 interface | 5VDC/200mA (RJ45) | |||||||
LCD backlight time | 60S (Default) | |||||||
Environmental | ||||||||
Working environment temperature◆ | -25℃~+50℃(100% input and output) | |||||||
Storage temperature range | -20℃~+70℃ | |||||||
Relative humidity range | ≤95%, N.C. | |||||||
Enclosure | IP33 ⑦ | |||||||
Pollution degree | PD2 | |||||||
Certification | ||||||||
Safety | EN/IEC62109-1 | |||||||
EMC(Emission immunity) | EN61000-6-3/EN61000-6-1 | |||||||
FCC | 47 CFR Part 15, Subpart B | |||||||
Performance &function | IEC62509 | |||||||
ROHS | IEC62321-3-1 | |||||||
Mechanical | ||||||||
Dimension(mm) | 175×143×48 | 175×143×48 | 217×158×56.5 | 217×158×56.5 | ||||
Mounting dimension(mm) | 120×134 | 120×134 | 160×149 | 160×149 | ||||
Mounting hole size | Φ5 | |||||||
Terminal | 12AWG/4mm2 | 12AWG/4mm2 | 6AWG/16mm2 | 6AWG/16mm2 | ||||
Recommended cable | 12AWG/4mm2 | 12AWG/4mm2 | 10AWG/6mm2 | 10AWG/6mm2 | ||||
Weight | 0.57kg | 0.57kg | 0.96kg | 0.96kg | ||||
① When selecting lithium battery type, the system voltage can’t be identied automatically ② At minimum operating environment temperature ③ At 25℃ environment temperature ④ When selecting lithium battery type, the temperature compensation coecient is 0,and can’t be set ⑤ The parameters are 12V system at 25 ºC, ×2 in 24V system at 25 ºC, ×4 in 48V system at 25 ºC ⑥ The controller can full load working in the working environment temp. range, When the internaltemperature reach to 81℃, the reducing charging power mode is turned on ⑦ 3 - protection against solid objects: protected against solids objects over 2.5mm 2 - protection against liquids: protected against direct sprays up to 15 ° from the vertical |
Model | XTRA3210N | XTRA4210N | XTRA3215N | XTRA4215N | ||||
Electrical | ||||||||
Nominal System Voltage | 12/24VDC① Auto | |||||||
Rated charge current | 30A | 40A | 30A | 40A | ||||
Rated discharge current | 30A | 40A | 30A | 40A | ||||
Battery Voltage Range | 8V~32V | |||||||
Max. PV open circuit voltage | 100V②/92V③ | 150V②/138V③ | ||||||
MPP voltage range | (Battery voltage +2V)~72V | (Battery voltage +2V)~108V | ||||||
Max. PV input power | 390W/12V 780W/24V | 520W/12V 1040W/24V | 390W/12V 780W/24V | 520W/12V 1040W/24V | ||||
Equalization Voltage ④ | Sealed: 14.6V; Flooded: 14.8V; User: 17~9V | |||||||
Boost Voltage ④ | Gel:14.2V; Sealed:14.4V; Flooded:14.6V; User: 17-9V | |||||||
Float Voltage ④ | Gel /Sealed /Flooded: 13.8V; User: 17~9V | |||||||
Low Voltage Reconnect Voltage ④ | Gel /Sealed /Flooded: 12.6V; User: 17~9V | |||||||
Low Voltage Disconnect Voltage ④ | Gel /Sealed /Flooded: 11.1V; User: 17~9V | |||||||
Self-consumption | ≤35mA(12V) ; ≤22mA(24V) | ≤35mA(12V); ≤22mA(24V) | ||||||
Discharge circuit voltage drop | ≤0.23V | |||||||
Temperature compensate coefficient | -3mV/℃/2V(Default) | |||||||
Grounding | Common negative grounding | |||||||
RS485 interface | 5VDC/200mA (RJ45) | |||||||
LCD backlight time | 60S (Default) | |||||||
Environmental | ||||||||
Working environment temperature◆ | -25℃~+50℃(100% input and output) | |||||||
Storage temperature range | -20℃~+70℃ | |||||||
Relative humidity range | ≤95%, N.C. | |||||||
Enclosure | IP33 ⑦ | |||||||
Pollution degree | PD2 | |||||||
Certification | ||||||||
Safety | EN/IEC62109-1 | |||||||
EMC(Emission immunity) | EN61000-6-3/EN61000-6-1 | |||||||
FCC | 47 CFR Part 15, Subpart B | |||||||
Performance &function | IEC62509 | |||||||
ROHS | IEC62321-3-1 | |||||||
Mechanical | ||||||||
Dimension(mm) | 230×165×63 | 255×185×67.8 | 255×185×67.8 | 255×185×67.8 | ||||
Mounting dimension(mm) | 120×134 | 200×176 | 200×176 | 200×178 | ||||
Mounting hole size | Φ5 | |||||||
Terminal | 12AWG/4mm2 | 12AWG/4mm2 | 6AWG/16mm2 | 6AWG/16mm2 | ||||
Recommended cable | 12AWG/4mm2 | 12AWG/4mm2 | 10AWG/6mm2 | 10AWG/6mm2 | ||||
Weight | 0.57kg | 0.57kg | 0.96kg | 0.96kg | ||||
① When selecting lithium battery type, the system voltage can’t be identied automatically ② At minimum operating environment temperature ③ At 25℃ environment temperature ④ When selecting lithium battery type, the temperature compensation coecient is 0,and can’t be set ⑤ The parameters are 12V system at 25 ºC, ×2 in 24V system at 25 ºC, ×4 in 48V system at 25 ºC ⑥ The controller can full load working in the working environment temp. range, When the internaltemperature reach to 81℃, the reducing charging power mode is turned on ⑦ 3 - protection against solid objects: protected against solids objects over 2.5mm 2 - protection against liquids: protected against direct sprays up to 15 ° from the vertical |
Model | XTRA3415N | XTRA4415N | ||||||
Electrical | ||||||||
Nominal System Voltage | 12/24/36/48VDC① Auto | |||||||
Rated charge current | 30A | 40A | ||||||
Rated discharge current | 30A | 40A | ||||||
Battery Voltage Range | 8V~68V | |||||||
Max. PV open circuit voltage | 150V②/138V③ | 150V②/138V③ | ||||||
MPP voltage range | (Battery voltage +2V)~108V | (Battery voltage +2V)~108V | ||||||
Max. PV input power | 390W/12V 780W/24V 1170W/36V 1560W/48V | 520W/12V 1040W/24V 1560W/24V 2080W/24V | ||||||
Equalization Voltage ④ | Sealed: 14.6V; Flooded: 14.8V; User: 17~9V | |||||||
Boost Voltage ④ | Gel:14.2V; Sealed:14.4V; Flooded:14.6V; User: 17-9V | |||||||
Float Voltage ④ | Gel /Sealed /Flooded: 13.8V; User: 17~9V | |||||||
Low Voltage Reconnect Voltage ④ | Gel /Sealed /Flooded: 12.6V; User: 17~9V | |||||||
Low Voltage Disconnect Voltage ④ | Gel /Sealed /Flooded: 11.1V; User: 17~9V | |||||||
Self-consumption | ≤35mA(12V) ; ≤22mA(24V) ≤16mA(36V) ; ≤16mA(48V) | ≤35mA(12V) ; ≤22mA(24V) ≤16mA(36V) ; ≤16mA(48V) | ||||||
Discharge circuit voltage drop | ≤0.23V | |||||||
Temperature compensate coefficient | -3mV/℃/2V(Default) | |||||||
Grounding | Common negative grounding | |||||||
RS485 interface | 5VDC/200mA (RJ45) | |||||||
LCD backlight time | 60S (Default) | |||||||
Environmental | ||||||||
Working environment temperature◆ | -25℃~+50℃(100% input and output) | |||||||
Storage temperature range | -20℃~+70℃ | |||||||
Relative humidity range | ≤95%, N.C. | |||||||
Enclosure | IP33 ⑦ | |||||||
Pollution degree | PD2 | |||||||
Certification | ||||||||
Safety | EN/IEC62109-1 | |||||||
EMC(Emission immunity) | EN61000-6-3/EN61000-6-1 | |||||||
FCC | 47 CFR Part 15, Subpart B | |||||||
Performance &function | IEC62509 | |||||||
ROHS | IEC62321-3-1 | |||||||
Mechanical | ||||||||
Dimension(mm) | 230×165×63 | 255×185×67.8 | ||||||
Mounting dimension(mm) | 120×134 | 200×176 | ||||||
Mounting hole size | Φ5 | |||||||
Terminal | 6AWG/16mm2 | 6AWG/16mm2 | ||||||
Recommended cable | 8AWG/10mm2 | 6AWG/16mm2 | ||||||
Weight | 2.07kg | 2.47kg | ||||||
① When selecting lithium battery type, the system voltage can’t be identied automatically ② At minimum operating environment temperature ③ At 25℃ environment temperature ④ When selecting lithium battery type, the temperature compensation coecient is 0,and can’t be set ⑤ The parameters are 12V system at 25 ºC, ×2 in 24V system at 25 ºC, ×4 in 48V system at 25 ºC ⑥ The controller can full load working in the working environment temp. range, When the internaltemperature reach to 81℃, the reducing charging power mode is turned on ⑦ 3 - protection against solid objects: protected against solids objects over 2.5mm 2 - protection against liquids: protected against direct sprays up to 15 ° from the vertical |