Enquiries
Message
Home > Products > Other
ELISA Kit for Interferon Beta (IFNb)
  • ELISA Kit for Interferon Beta (IFNb)

ELISA Kit for Interferon Beta (IFNb)

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Wuhan, China
Brand Name:
Cloud Clone Corp.
Model Number:
SEA222Ca
Power Source:
Manual
Warranty:
NONE
After-sale Service:
Online technical support
Power Supply Mode:
Plug-in
Material:
Plastic
Shelf Life:
3 years
Quality Certification:
ce
Instrument classification:
Class I
Safety standard:
None
Type:
Blood Testing Equipments
Organism Species:
Canis familiaris; Canine (Dog)
Sample Type:
Tissue homogenates, cell lysates and other biological fluids
Detection Range:
15.6-1000pg/mL
Sensitivity:
less than 6.4pg/mL
Supply Ability
Supply Ability:
2000 Box/Boxes per Month
Packaging & Delivery
Product Description

Specificity

This assay has high sensitivity and excellent specificity for detection of Interferon Beta (IFNb).
No significant cross-reactivity or interference between Interferon Beta (IFNb) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Interferon Beta (IFNb) and the recovery rates were calculated by comparing the measured value to the expected amount of Interferon Beta (IFNb) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-105 101
EDTA plasma(n=5) 93-101 96
heparin plasma(n=5) 82-93 86

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interferon Beta (IFNb) were tested 20 times on one plate, respectively. 
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interferon Beta (IFNb) were tested on 3 different plates, 8 replicates in each plate. 
CV(%) = SD/meanX100 
Intra-Assay: CV<10% 
Inter-Assay: CV<12% 

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interferon Beta (IFNb) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-94% 78-90% 79-94% 84-101%
EDTA plasma(n=5) 93-101% 78-93% 82-99% 89-98%
heparin plasma(n=5) 80-105% 80-97% 89-96% 83-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. 
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Product Description

Specificity

This assay has high sensitivity and excellent specificity for detection of Autoimmune Regulator (AIRE).
No significant cross-reactivity or interference between Autoimmune Regulator (AIRE) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Autoimmune Regulator (AIRE) were tested 20 times on one plate, respectively. 
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Autoimmune Regulator (AIRE) were tested on 3 different plates, 8 replicates in each plate. 
CV(%) = SD/meanX100 
Intra-Assay: CV<10% 
Inter-Assay: CV<12% 

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. 
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Packaging & Shipping

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately. 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher