Enjoy Classic Technology
• The design of metal transparent material and breathing lamp perfectly combines technology and fashion elements, making the instrument frame a new design language.
• The left and right symmetrical beam line design inside the column enables the flow path to be in a ring layout, which has the function of storage.
• Black surface material is resistant to corrosion by solvents used in conventional HPLC.
Automatic Super Accurate Measurement
• The automatic calibration of dark current is realized by using the "dark" array technology.
• The control circuit is used to control the lens switching mechanism and the dynamic variable slit device automatically, and the automatic real-time calibration of the data signal is realized, and the accuracy of the detection results is improved.
Long - lasting High Precision
• Innovative double-seal floating plunger, motor driven CAM driven plunger, to achieve accurate fluid transmission, with a new drive control method, reduce the system of infusion pulsation, improve the durability and precision of the instrument.
• Intelligent high-precision CAM detection device, ingenious design, reasonable layout, matching can simulate the actual working situation of the push rod structure, improve and ensure the validity of detection data.
• Double contrast loop leakage sensor and perfect guide groove design make leakage alarm more accurate and timely.
Flexible and Efficient
• Through the highly integrated controlled solvent switching system, the high pressure binary can have the function of double high pressure binary, or even double four high pressure, so that the complex work is simple.
• The automatic dilution and derivation function of the automatic sampler makes the experiment easier.
• It can be used in ultra performance liquid chromatography.
• Can be used as a front end of mass spectrometry.
Easy Composition, Perfect Baseline
• In the experimental process, when the proportion absorbance of two phases of AB at the set wavelength is greatly different, the low proportion mixing is prone to regular pulsation of the baseline. The E3200 high-pressure constant-current pump uses a patented design pulse damper coupled with a gradient mixer to greatly reduce pulsation and improve mixing performance, even with perfect baseline performance at the ultimate ratio of 1:99.
Easy Induction
• Different analytical methods are often encountered in the experiment, and the sensitivity is different in different detection environments.
• The E3200 system's independent new detection pool, unique air channel system and micro-step driver control the static Angle, while achieving high precision, high sensitivity, low noise, low drift performance, so that the laboratory analysis work to achieve twice the result with half the effort.
Easy Analysis, Stable Realization of Various Quantitative Needs
• The data acquisition system adopts 24-bit high-precision AD conversion chip, with high data acquisition accuracy and wide linear range up to 2.5AU, which can meet the requirements of high concentration and micro quantitative analysis at the same time.The injection volume of 0.1-50HL reached R2=0.9999, and it had perfect performance in either small injection volume or large injection volume.
Easy to Use, Smooth Communication
• Kromstation is a chromatography workstation software independently developed by our company, which conforms to CNAS certification. Strong database, audit tracking, GLP, data archiving and backup, electronic signature, permission setting, network management and other functions, KromStation software can be perfectly realized.