Description-Durable 24v dc to ac 110v 14.4a high power inverter with battery over protection
True sine wave output (T.H.D < 3%);
Large 128*64 digital Lcd display data information,4 led display working;
Standard 19” Rack mount case;
5 Routes Dry contact for system (DC input fault, AC input fault, overload information, by-pass information and output fault)
Function-Durable 24v dc to ac 110v 14.4a high power inverter with battery over protection
RS232 and RS485 & Optional SNMP communication Port;
Power-on self-test, Soft output start;
Audible and visual alarm;
Record the historical alarm message and can be queried;
Real-time monitoring of the system operating status;
Feature-Durable 24v dc to ac 110v 14.4a high power inverter with battery over protection
Auto switch function: DC to AC, AC bypass, less than 5ms;
By-pass AC 220V input filtering;
Start auto restart while Ac or Dc is recovering;
Automatic start temperature control fan
Build in voltage regulator Stabilize AC voltage;
Protection :Short load protection, over load protection, battery over/under voltage protection, over current, over temperature;
Unattended operation: the system switches automatically to provide AC Power to the load between the DC input and AC input;
Model |
VT-HF24S110-2KVA |
||
DC INPUT |
Rated Input Voltage(Vdc) |
24V |
|
|
Rated Input Current (A) |
83A |
|
|
DC Input Range (Vac) |
20-30V |
|
|
Reflected Noise Current. |
≤10% |
|
AC Bypass Input |
Bypass Voltage Range (Vac) |
132V-90V(±10V) |
|
|
Rated Input Current(A) |
18.1A |
|
AC Output |
Capacity(VA) |
2KVA |
|
|
Rated output Capacity(W) |
1600W |
|
|
Output Voltage and Frequency |
110Vac 50Hz/60Hz |
|
|
Output Current(A) |
14.4 |
|
|
Voltage Accuracy(V) |
220±1.5% |
|
|
Frequency Accuracy(Hz) |
50±0.1% or 60±0.1% |
|
|
Waveform |
Pure Sine Wave |
|
|
THD |
≤3%(line load ) |
|
|
Dynamic Response Time |
5%((load 0←→100%) |
|
|
Power Factor(PF) |
0.8 |
|
|
Overload Capability |
100%-120% 60s |
121%-150% 10s |
|
Inverter efficiency(80% line load) |
≥85% |
|
|
Inverter ←→ Bypass(ms) |
≤8ms |
|
working environment |
Dielectric Strength(Input & Output) |
1500Vac-10mA,1minutes |
|
|
Noise(1m) |
≤55dB |
|
|
Ambient Temp. |
-20℃~+50℃ |
|
|
Humidity |
0~90%,No condensation |
|
|
Altitude(m) |
≤2000 |
|
Indicate |
LCD Display |
Input/output Voltage/Frequency/Output Current/Temp/Capacity Rate etc |
|
|
Inverter Status |
Off Grid Status/Inverter Status/Batter Under&Over Voltage/Output Over load
|
|
Dimensions |
Standard 19”Rack mount(D×W×H) |
482*347*88MM |
|
|
Package Dimension
|
562*492*195mm |
|
Weight |
N.W |
9.00KG |
|
|
G.W |
11.00KG |
|
Protection |
Input under Voltage/Input over Voltage/Output Over load/Short circuit |