Dry dispersion He-Ne laser auto feeding winner3003A Laser particle size analyzer
Brief introduction:
Winner3003 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results.
This product use air as the dispersing medium, the use of turbulent dispersion principle, with high-precision feeding apparatus and Patent powder injection pumps, No-Oil silent air source, ensure that the sample is thoroughly dispersed. It is applied to any powder material, particularly good for materials occurs chemical reaction in water, or shape change in the liquid. It have same accuracy and repeatability compared with the wet method.
Main Specifications:
Model Name | Winner3003A | Winner3003B | ||
Size Range | 0.1-300μm | 0.1-500μm | ||
Standard | ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013 | |||
Channels Number | 40 pcs | 40 pcs | ||
Accuracy error | <1% (Deviation of D50 on national standard sample) | |||
Repeatability error | <1% (Deviation of D50 on national standard sample ) | |||
Light Source | He-Ne laser (λ= 632.8nm, P>2.0MW) | |||
Dispersion Method | Dry-turbulence dispersion mode | |||
Operation Mode | Manual/Automatic | |||
Optical Path Calibration System | Automatic | |||
Dispersing Medium | Compressed air | |||
Test Speed | <1min for each time | |||
Operation System | Win XP/ Win 7 | |||
Connection Port | USB | |||
Software function | Analysis mode | Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification | ||
Statistic Method | Volume Distribution, Quantity Distribution
| |||
Statistic Comparison | Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time.
| |||
User-defined Analysis | Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries. | |||
Test Report | Word, Excel,Photo( Bmp), Text etc | |||
Multi-language Support | Chinese&English
| |||
Intelligent Operation Mode | Automatically control Air flow speed, dispersion,test and analysis.Better Repeatability after remove human-factor | |||
Volume | L88cm×W40cm×H30cm | |||
Net Weight | 36Kg |
Main Features:
1) Unique patent technology of optical path and detection system, greatly improve testing resolution.
Converging Fourier transform optical path patent technology overcome lens aperture restriction on the scattering angle, expand testing range in limited space, and add more secondary integrated photodetectors, which can effectively collect scattered light from all angles in the the corresponding test range, make sure the testing accuracy and reliability within the full range.
2)Scientific and automatic dry dispersion method
Turbulence dispersion patented technology and Normal shock shearing effect make particles sufficient dispersion, dispersion core part using wearable ceramics not only improve dispersion system’s working life but ensure more accurate and stable particle size testing result.
3)Intelligent Operation System realize one key test
Just need put in sample, Dust collection, air supply,feeding and others are all automatic. It only only reduces workload, but eliminate errors caused by human factors, further improve testing accuracy and authenticity of the testing results.
4)Software support
Unique unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution, ensure accuracy of testing result.
Figure-Winner3003A instrument scheme
Application:
Winner3003 Dry laser particle size analyzer used in cement, ceramics, pharmaceuticals, dyes, pigments, fillers, chemical products, catalysts, coal dust, additives, pesticides, explosives, graphite, photographic materials, fuel, metal and non-metal powder, carbonated calcium, kaolin and other powder industry, particularly for materials which occurs chemical reaction, the shape change and the loss in the liquid, such as herbs, magnetic materials and relatively wide distribution and larger particles powders, have more unique applicability and practicality.
Auxiliary device equipped also:
Standard accessories:
Patent Technology:
Winner Particle Instrument Stock Co.,Ltd. have been specialized in laser particle size analyzer since 1985, as the leading manufacturer in China, winner undertake the national science and technology project for many times, get more than 30 patents technology, Strongly recommended by 500 Universities in China!
1st Circulation test wet particle size analyzer
1st Dry particle size analyzer
1st Dynamic particle image instrument
1st Nano particle size analyzer
1st Image laser particle size analyzer
1st Inline particle size analyzer
Our goal is to provide super quality and competitive price laser particle size analyzer for clients all over the world!
We created more than 10 first particle size analysis technology in China!
Purchase laser particle size analyzer need know points:
1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also.
Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.
2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.
3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.
For dry dispersion model, just use compressed air as dispersion media.
In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.
More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!