VRDLC3100 Series
Smart Displacer Liquid Level (Interface) Transmitter
Equipped with FISHER FIELDVUE DLC3100
AND FISHER 249 CONSTRUCTURE
VRDLC3100 series smart displacer level (interface) transmitters use the original Fisher FIELDVUE DLC3100 digital level controller which is the updated version of the DLC3010 series controller and imported from Emerson. Other pares are manufactured by V-river locally. The transmitter is suitable to measure liquid level, interface level, or liquid specific gravity (density). The buoyancy force from the liquid, which changes with the liquid level’s change, is exerted on the displacer, which rotates the torque tube shaft. This rotary motion is transferred to the digital level controller, then the liquid level change finally is changed into current signals 4-20mA, which is sent out from the digital level controller.
DLC3100 series smart level transmitters are communicating, microprocessor-based level, interface or density sensing instruments. In addition to the normal function of providing 4~20mA current signal, DLC3100 series smart level transmitter, using HART communications protocol, give easy access to information critical to process operation. You can gain information from the process, the instrument, or sensor, using a communicator 275 or 375 with HART protocol, being compatible with DLC3100. The HART Communicator may be connected at the digital level controller or at a field junction box. By using the HART communicator, the user can perform several operations with the transmitter. The user can interrogate, configure, calibrate, or test the smart level transmitter. Using the HART protocol, information from the field can be integrated into control systems or be received on a single loop basis. In addition, the transmitter has platinum RTD for sensing process temperature to permit compensating for changes in specific gravity to improve its measurement accuracy, linearity and repeatability.
DLC3100 Series smart level transmitters can be widely used in many industrial areas, such as oil and gas, petrochemical, refinery, chemical, metallurgy, medicine and food industries, etc.
Mounting positions: right- or left-of-displacer
Operating pressure (MPa): 4.0, 6.3, 16.0, 20.0, and 32.0 or higher on request.
Operating temperature: -190℃ - +29℃ for Low-temp type;
-19℃- +150℃ for normal type;
+150℃- +350℃ for high-temp type,
+350℃ - +427 ℃ for ultra-high temp type,
Flange connections: JB/TB82.2-94, HGJ, GB, ANSI, JIS,or on request.
Materials: Displacer: 1Cr18Ni9Ti, 316L
Measuring cage: carbon Steel, 1Cr18Ni9Ti, 316L
Explosion proof: Ex d IICT6 and Ex ia IICT6
Differential density: 0.4-1.5g/cm3 (liquid level) and 0.05~0.5g/cm3 (liquid interface)
Electrical connections: Two 1/2’’ - 14 NPT internal conduit connections. Both are at the bottom of terminal box.
Supply requirements: 12 to 30 volts DC; 25mA. Instrument has reverse polarity protection. A minimum compliance voltage of 17.75 V DC (due to HART impedance requirement) is required to guarantee HART communication.
Output signal: two-wire, 4 - 20 mA DC,
Direct action - increasing level, interface, or density, increase output; or
Reverse action - increasing level, interface, or density, decreases output
High saturation:20.5mA; Low saturation:3.8mA
High alarm:> 21.0mA; Low alarm: <3.6mA
Digital: HART 1200 Baud Frequency Shift Keyed (FSK)
HART impedance requirements must be met to enable communication. Total shunt impedance across the master device connections (excluding the master and transmitter impedance) must be between 230 and 600 ohms.
Accuracy: ±0.2% for Level, ±0.5% for interface
Ambient temperature: -40 - +80℃
LCD operating temperature limits: -20 - +70℃
Electrical housing protection grade: IP66, type 4x
Hazardours area: CSA/ FM/ ATEX/ IECEx/ SIL2