Model | OSCI-DSO1200 | OSCI-DSO1060 |
Bandwidth | 200MHz | 60MHz |
Channel | 2 | |
Real-Sample Rate | 500MSa/s | 250MSa/s |
Equivalent Sample Rate | 50GSa/s | |
Record Length | 32K | |
Rish time | ≤1.7ns | ≤5.8ns |
Timebase Accuracy | ±50ppm | |
Time Base Range | 5ns/div-1000s/div | |
Video Help | -- | |
SD Card | -- | |
Input Impandance | 1MΩ ΙΙ 15pF | |
VOLTS/DIV Range | 10mV/div~5V/div | |
A/D Converter | 8bit | |
Position Range | ±50V(5V/div), ±40V(2V/div~500mV/div), ±2V(200mV/div~50mV/div), ±400mV(20mV/div~2mV/div) | |
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div | |
Bandwidth Limit | 20MHz | |
Trigger Types | Edge, Video, Pulse, Alternative | |
Trigger Source | CH1, CH2 | |
Math | +, -, x, ÷, FFT, Invert | |
Cursor Measurement | Voltage difference between cursors: V; Time difference between cursors: T; Reciprocal of T in Hertz (1/T); | |
Auto Measuerment | Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot | |
The float voltage between BNC and Ground | -- | |
The float voltage between each Channel | -- | |
The float voltage between Multimeter and Ground | -- | |
between input Ports directly | -- | |
Input by 10:1 probe | -- | |
DMM Max. Resolution | 6,000 Counts | |
Testing Modes | Voltage, Current, Resistance, Capacitance, Diode & Continuity | |
Max. Input Voltage | AC: 600V, DC: 800V | |
Max. Input Current | AC:10A , DC: 10A | |
Max. Input Impandance | 10MΩ | |
Display | 5.7" TFT 16K Color Display, 320*240 dots | |
Size | 245mm x 163mm x 52mm | |
Weight | 1.3KG(Without Package) | |
Standard Probe | PP200x2 | PP80x2 |
DMM Mode | |||
Max. Resolution | 6000 Counts | ||
DMM Testing Modes | Voltage, Current, Resistance, Capacitance, Diode & Continuity | ||
Max. Input Voltage | AC:600V, DC: 800V | ||
Max. Input Current | AC: 10A, DC:10A | ||
Input Impedance | 10MΩ | ||
DMM TrendPlot | 1.2M Point | ||
Range | Resolution | Accuracy | Resolution |
DC Voltage | 60.00mV | ±1%±3 digit | 10uV |
600.0mV | 100uV | ||
6.000V | 1mV | ||
60.00V | 10mV | ||
600.0V | 100mV | ||
800V | 1V | ||
AC Voltage | 60.00mV | ±1%±3 digit | 10uV |
600.0mV | 100uV | ||
6.000V | 1mV | ||
60.00V | 10mV | ||
600.0V | 100mV | ||
DC Current | 60.00mA | ±1%±5 digit | 10uA |
600.0mA | ±1.5%±5 digit | 100uA | |
6.000A | 1mA | ||
10.00A | 10mA | ||
AC Current | 60.00mA | ±1%±5 digit | 10uA |
600.0mA | ±1.5%±5 digit | 100uA | |
6.000A | 1mA | ||
10.00A | 10mA | ||
Resistance | 600Ω | ±1%±3 digit | 0.1Ω |
6.000KΩ | 1Ω | ||
60.00KΩ | 10Ω | ||
600.0KΩ | 1KΩ | ||
6.000MΩ | 10KΩ | ||
60.00MΩ | ±1%±5 digit | 100KΩ | |
Capacitance | 40.00nF | ±2%±5 digit | 10pF |
400.0nF | 100pF | ||
4.000uF | 1nF | ||
40.00uF | 10nF | ||
400.0uF | 100nF | ||
Attention: the smallest capacitance value that can be measured in 5nF | |||
Diode | 0V~2.0V | ||
ON-OFF test | <10Ω |